Caution:

1. Cut off the main power first
2. Don’t touch LED while maintaining or cleaning
3. Don't use chemical reagent to clean lamp.

Environmental protection: waste electrical products should not be disposed of with household waste. Please recycle 
where facilities exist. Check with your local authority or retailer for recycling advice.

Maintenance

1. The product must be installed by professional technicians and power supply must be cut off before installation.
2. The installation wiring must be 0.75mm

2

 at least and wired in accordance with the latest IEE electrical 

    regulations or the national requirements. 
3. Do not touch the electronic circuit and its components.
4. Contact an authorised technical service centre for any repairs possibly required use only original spare parts.
5. Do not touch LED while installing or maintaining.
6. The LED light source can not be replaced.

Detection Pattern

ceiling mounting pattern (m)

5m

8m

wall mounting pattern (m)

9m

4m

RoHS

SAA

IP54

TM

Sensor On-off / dimming setting options (For code M320 18 SOF / M320 18 SDM / M320 18 STM)

Hold-time

5s~10min 

5m

8m

Stand-by period

0s~+ 8

Detection area can be reduced by selecting the 

combination on the DIP switches to fit precisely for 

each specific application.

Detection area

I –  100%

II –  50%

1

I

II

50%

100 %

Hold-time means the time period you would like to 

keep the lamp on 100% after the person has left the 

detection area.

I – 5s

II – 30s

III – 3min 

IV – 10min

30s

5s

10min

3

2

I

II

III
IV

3min

I – 0s

II – 30s

III – 10min 

IV – +

This is the time period you would like to keep at the 

low light output level before it is completely switched 

off in the long absence of people.

Stand-by period (corridor function)

I – Disable

II – 50Lux

III – 10Lux

IV – 2Lux

Daylight sensor

The daylight threshold can be set on DIP switches, 

to fit for particular application.

5

4

50Lux
10Lux

2 Lux

Disabl

e

I

II

III
IV

30s

0s

+∞

7

6

I

II

III
IV

10min

Hold-time

2~50Lux

Note: “0s” means on/off control;

         “+    ” means bi-level dimming control, fixture 

          never switches off.

8

I –  10%

II –  30%

8

I

II

30%

10%

This is the dimmed low light output level you would 

like to have after the hold-time in the absence of 

people.

Stand-by dimming level

3

4

AC cables come in through plastic plug, and 
are connected to the terminal block.