EL.MO. Spa PREGIO Series Скачать руководство пользователя страница 6

6

Fri01/09/17 9:00

Welcome

Area 1

SECTORS SELECTION

U

U

U

U

U

U

(default: 111111)

 

– Key in user code.

 

– Press 

OK

.

Pre-arming mode starts. Sector keys of sectors proposed for 

arming will start blinking (for the specific user in the current-

ly operating area).

 

– Press a sector key (S1, S2, S3, S4) to change the sectors 

proposed (if authorised for the specific user).

The interval between the pressure of one key and the 

following one must not be over 5 seconds otherwise 

the system will arm.

Example

If sectors proposed for arming at the beginning are S1 and 

S3

S1

S3 S4

S2

when you press key S2 (if authorised) also sector 2 will be 

proposed for arming.

S1

S3 S4

S2

If you press key S2 again, sector 2 will be excluded from 

sectors proposed.

 

– To change area, press arrow keys ↑ or ↓, then select sec-

tors to be armed.

 

– When finished, press 

OK

 to start arming, 

STOP

 to cancel 

it.

 

– If exit time has been set, it will be marked by beep sounds: 

leave the protected areas within the set time walking 

through the path set.

At the end of exit time, sectors proposed will be armed (sec-

tor keys remains lighted unless the option 

Hide Arming Sta-

tus

 is enabled).

if one selected sector cannot be armed, the arming 

procedure will be stopped.

2.4.4   system arming with sectors selection 

- 8/16 sectors per area mode

Under 8/16 Sectors per area mode, sector keys are associat-

ed to 

sectors group

.

Sector keys arm/disarm sector groups. The key-sectors as-

sociation is made during setup.

 

– Key in user code.

 

– Press 

OK

.

Keys of sectors proposed for arming for a specific user will 

blink in the currently operating area.

On the keypad display, a number / letter indicates that the 

sector associated is proposed for arming (under 16 sectors 

per area mode letters A to G represent sectors from 10 to 

16); hyphens indicate sectors not proposed for arming.

8 Sectors mode

Area 1

Arm: 123--67-

16 Sectors mode

Area 1

123--67-9AB----G

During key blinking (pre-arming time, around 5s), it is possi-

ble to change sectors proposed either per single sector, or 

per sectors group.

Per single sector:

Press a number key to change a single sector proposed (as 

long as the sector selected is authorised for the user).

 

▼ 8 sectors mode

Press numeric keys from 

1

 to 

8

.

 

▼ 16 sectors mode

Press numeric keys from 

1

 to 

9

*

 (= A), 

0

 (= B), 

#

 (= C). 

The single sector selection is not available for D, E, F, 

and G sectors.

If sectors proposed for arming at the beginning are number 

1, 2, 3, 6, 7

Area 1

Arm: 123--67-

when you press key 8 also sector 8 will be proposed for 

arming (as long as it is authorised for the user):

Содержание PREGIO Series

Страница 1: ...l control units are protected against the cover opening and removal from wall Icons used in this manual Example of messages on keypad display Fri01 09 17 9 00 Area 1 Keys typing Usage example Manual contents Keypads usage operating mode from keypad cap 2 p 1 Proximity keys usage operating mode from keypad cap 3 p 11 Remote controls usage operating mode with remote control cap 4 p 13 GSM and phone ...

Страница 2: ...or key provides information about arming status of corresponding sectors Key status Indication OFF All sectors associated to the key are disarmed ON All sectors associated to the key are armed Fast blinking All sectors associated to the key are armed with maximum security Fast blinking alternate to steady light At least one sector associated to the key is armed but not all Slow blinking Exit time ...

Страница 3: ...It indicates general alarm OFF no alarm events ON alarm in progress active relay Blinking alarm memories To reset alarm memories arm and disarm the system 4 Tamper LED It indicates tamper status OFF no tampering zones ON tamper alarm in progress active relay Blinking tamper alarm memories To reset alarm memo ries arm and disarm the system Once the system has been armed if the option Visual isation...

Страница 4: ...If during installation the option Enable keypad locking for error code has been enabled the keypad will be blocked after the wrong code has been entered for three times The following message will be displayed for 90 seconds TEMPORARY DISABLEMENT Further options are available for associating tamper events generation with wrong codes typing Please see product programming manual 2 3 Display the statu...

Страница 5: ...ction devices detectors magnet ic contacts etc During unit configuration some zones can be included into exit path After system arming users can leave the premis es within a set time exit time through the exit path without triggering an alarm event Exit path zones can be set as exit door when users exit and close the door the remaining exit time will reset and the unit will arm The subsequent open...

Страница 6: ...annot be armed the arming procedure will be stopped 2 4 4 System arming with sectors selection 8 16 sectors per area mode Under 8 16 Sectors per area mode sector keys are associat ed to sectors group Sector keys arm disarm sector groups The key sectors as sociation is made during setup Key in user code Press OK Keys of sectors proposed for arming for a specific user will blink in the currently ope...

Страница 7: ...be armed without entering the user code Arming with sector key OK The option Activate fast arming in BrowserOne has to be activated Press sector key of the sector to be armed the sector can be armed if it is authorised at least to one user The key will start blinking Sector S1 A1 FAST ARMING Press OK to confirm if not the procedure will be can celled after 5s If an exit time has been set leave the...

Страница 8: ...m arm disarm Forced arming through keypad If the option Activate arming lock is enabled in Browse rOne system arming will be denied if some fault conditions occur When the arming is denied due to a dialler failure or lack of supervision users can force the arming only through the keypads controlling the areas involved in the arming denied When forced arming is allowed the following message will be...

Страница 9: ...press STOP repeatedly after an operation you may be asked to save changes SAVE CHANGES Ok Yes No While in user menu the 4 LED indicators will blink simultaneously The user menu lists the following items on the right the number of the paragraph with details on the items MAINTENANCE BYPASS ZONES 2 5 1 p 9 INSTALLER AUTH 2 5 2 p 9 OUTPUT CONTROL 2 5 3 p 10 MANAGE SIM BAL 2 5 4 p 10 CLOCK SETUP 2 5 5 ...

Страница 10: ...or press STOP to exit the menu without saving 2 5 6 Clock calibration Use this menu to manually adjust the difference in time oc curred over a month between the control unit clock and the standard one Use arrow keys or to go to CLOCK CALIBR option Press OK to enter the menu Use arrow keys or to increase decrease seconds per month 5s month steps Press OK to save and exit the menu or press STOP to e...

Страница 11: ...acti vated for 6 seconds and the activation can be interrupted by pressing key Once the test is completed press STOP to exit test step Use arrow keys or to go to the next step DIALLER TEST Press OK to start the test The dialler activates and the message TEST CALL will be displayed Press OK again to start the test Wait for test to be com pleted the message NOT EXECUTAB will be displayed if the dial...

Страница 12: ...age Before proceeding please see arming general information paragraph 2 4 1 p 5 3 2 1 System arming Place the proximity key near the sensitive area onto reader or keypad The pre arming time will start around 5s if there are sector keys users can modify sectors proposed for arm ing Please see paragraph 2 4 3 p 5 When the pre arming time elapses the exit time will start if set Leave the protected ar...

Страница 13: ...ock 4 REMOTE CONTROLS USAGE Remote control devices can be used to arm either totally or partially and disarm systems Remote controls have to be learned to a specific device Remote control Device ATLANTE4 ATLANTE6 RIVERRF ATLANTE4PLUS RIVERRFPLUS ATLANTE2K GATEWAY2K 4 1 Function keys The following image refers to ATLANTE2K device Other de vices may not feature the same function keys A Key TOTAL ARM...

Страница 14: ...s not allowed because of dialler fault or lack of supervision events users can force system arming only us ing control devices that control areas involved in the arming lock Within 15 seconds to force arming press again the re mote control key previously selected Bypassed detectors will not cause system lock 5 GSM AND PHONE COMMUNICATIONS PREGIO1000 PREGIO1000BM and PREGIO2000 control units suppor...

Страница 15: ...anced settings The installer can set advanced settings using BrowserOne software 5 6 1 Dialler block at disarming Users can require to block phone communications voice and digital caused by sectors disarming Dialler block function is available in Options menu in BrowserOne If dialler block is removed the phone dialler will activate when the first event generated after the removal occurs 5 6 2 Limi...

Страница 16: ...g an SMS text with S 3 7 E CONNECT e Connect is a supervision software for EL MO intrusion de tection systems It allows users to control and manage their systems via the Internet a PC or a smartphone application Operations with e Connect software check control unit status anomalies tamper events alarms arm disarm procedures read events log enable disable outputs For the correct use of the software...

Страница 17: ...ity mode and a user with max security prop erty performs a disarm the Weekly Programmer Max Security property remains active Therefore at the next control unit arming it will be armed with Max Se curity property even if the arming is performed by a user without the Max Security property However if the disarming is performed via weekly programmer Max Security Reset function the sector property will...

Страница 18: ...e unit and the unit will reply with another SMS text The command sent will be accepted only if sent by a number on the unit phone number list 9 1 SMS structure SMS text shall be in the following form C nnnnnn X X where nnnnnn code of the user sending the SMS 6 digits X X code of the command see table Leave an empty space between C nnnnnn and X X With a single SMS text it is possible to send up to ...

Страница 19: ...ser TAMPER ALARM MEMORY Tamper alarm memory at one of the areas authorised for the user INTRUSION ALARM Intrusion alarm at one of the areas authorised for the user INTRUSION ALARM MEMORY Intrusion alarm memory at one of the areas authorised for the user PANEL ANOMALY One of the areas authorised for the user signals an anomaly or there is a memory for such event GSM ON GSM module on GSM TURNING OFF...

Страница 20: ...ctors disarmed A DENIED Arming impossible D DENIED Disarming impossible 9 3 2 GSM ON OFF Replying SMS Indication GSM ON GSM module on GSM TURNING OFF GSM module is turning off G DENIED GSM on off functions disabled or the user is not authorised for Small Maintenance 9 3 3 Remote listening request Replying SMS Indication REMOTE LISTENING REQ Command M ON recognised 9 3 4 Activate deactivate outputs...

Страница 21: ...w or absent It may be necessary to replace battery protection fuse ANOMALY Mains failure Mains failure the unit is powered by the battery only ANOMALY Tel Line Fault Phone line not detected or absent ANOMALY No GSM Registr SIM card missing or disabled or PIN code active KEYP RD TAMPER Keyp Rd 1 Keypad or reader the number of which is indicated signals a tamper event ANOMALY SIM Balance SIM balance...

Страница 22: ...22 ...

Страница 23: ...uress mode p 12 3 2 4 System forced arming p 13 4 REMOTE CONTROLS USAGE P 13 4 1 Function keys p 13 4 2 Operation with remote controls p 13 4 2 1 System arming p 13 4 2 2 Disarming p 14 4 2 3 Disarming with duress mode p 14 4 2 4 Panic event p 14 4 2 5 System forced arming p 14 5 GSM AND PHONE COMMUNICATIONS P 14 5 1 Calls reception p 14 5 1 1 Remote listening p 14 5 2 Receiving SMS from control u...

Страница 24: ...ducts include batteries re chargeable or otherwise as an emergency backup power supply If connected incorrectly they may cause damage to the product or prop erty and may endanger the operator explosion and fire INSTALLER WARNINGS Comply strictly with current standards governing the installation of elec trical systems and security systems and with the manufacturer s direc tions given in the manuals...

Отзывы: