![ekwb EK-XRES Glass Revo D5 Series Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/ekwb/ek-xres-glass-revo-d5-series/ek-xres-glass-revo-d5-series_installation-and-mounting-manual_2374623002.webp)
Released on 4
st
of January, 2016.
STEP 4: ATTACHING FITTINGS
EK-XRES Glass Revo D5 PWM (incl. pump) series reservoir pump combo featured 2 (two) G1/4 threaded ports on the main body of which 1 (one) is inlet and other is outlet.
Reservoir has 3 (three) options for inlet port one is on the main boy near outlet port and three are placed on reservoir top. EKWB recommends using EK-ACF fittings with the
EK-XRES Glass Revo D5 PWM series reservoir pump combo units. To ensure that the tubes are securely attached to the barb/fittings, please use hose clamps or an appropriate
substitute.
It is mandatory to use the correct INLET and OUTLET ports:
1.
The OUTLET port (pressure port) is, when the reservoir sits in upright position
2.
The INLET port(s) (suction port) are the port with G1/4 threading plane.
3.
Make sure not to use fittings or barbs with G1/4 thread longer than 5mm! All
EK-ACF,
EK-HDC
fittings are compatible!
TIP:
If INLET port is chosen to be on reservoir top part, install EK Extender G1/4 before
installing EK-ACF or EK-HDC fitting.
To fill the reservoir use one of three fill ports on the top of the reservoir!
When the pump is mounted make sure that water line is at least 10mm above suction
holes which are located on the center connection pipe.
1IMPORTANT DISCLOSURES:
VERY IMPORTANT NOTICE: Once the installation is completed, it is a recommended practice to test the cooling circuit for leaks prior to powering up the computer. We
recommend a 24 hour leak test prior to powering up the computer. Do not test the water block using tap water pressure. This will rupture the top of the housing and render
the block unusable (and will void your warranty). While all efforts have been made to provide the most comprehensive tutorial possible, EK Water Blocks assumes no liability
expressed or implied for any consequential damage(s) occurring to your equipment as a result of using EK Water Blocks cooling products, either due to errors or omissions on
our part in the above instructions, or due to failure or defect in the EK Water Blocks cooling products.
WARRANTY:Our products are warranted against defects in materials or workmanship for a period of 24 months beginning from the date of delivery to the final user. During this
period, products will be repaired or have parts replaced at our discretion provided that: (I) the product is returned to the agent from whom it was purchased; (II) the product
has been purchased by an end user and has not used for commercial purposes; (III) the product has not been misused, handled carelessly, or used in a manner other than in
accordance with the instructions provided describing its installation and proper use. This warranty does not confer rights other than those expressly set out above and does
not cover any claims for consequential loss or damage. This warranty is offered as an extra benefit and does not affect your statutory rights as a consumer. This warranty is
voided if the product comes in contact with aggressive additives or other improper liquids.
Any other RMA issues can be reported to
(this paragraph is intentionally left blank)
REQUIRED TOOLS:
Allen key 2.5mm, allen key 2mm and allen key 6mm (are enclosed)
power drill with 4,5mm drill bit or equivalent (optional)
EK-ACF Fitting
EK-Plug G1/4
Fill port
Inlet
Outlet
Vertical mount
mount