Revision 1.0. Released on 19
th
of February, 2013.
Installation and mounting manual for
EK-XRES DCP 2.2 Reservoir
This product is intended for installation only by expert users. Please consult with a qualified technician for installation. Improper installation may result in damage to your equipment. EK Water Blocks assumes no liability
whatsoever, expressed or implied, for the use of these products, nor their installation. The following instructions are subject to change without notice. Please visit our web site at
installation of this product please read important notice, disclosure and warranty conditions printed on the back of the box.
Before you start using this product please follow these basic guidelines:
1.
Please carefully read the manual before through before beginning with the installation process!
2.
The EK High Flow and EK-PSC or EK-CSQ type fittings require only a small amount of force to screw them firmly in place since the liquid seal is ensured by the rubber o-ring gaskets.
3.
The use of quality, market proved corrosion inhibiting coolants is strongly recommended for any liquid cooling system.
GENERAL INFORMATION.
Sample picture of exploded EK-XRES DCP 2.2
STEP 1: PREPARING THE PUMP
Unscrew original M3 screws with Philips head screwdriver
and store them in a safe place. These screws will not be
needed any more.
STEP 2: PREPARING THE PUMP CONTINUED
STEP 3: CONNECTING THE PUMP AND RESERVOIR
Use four enclosed M3x16 DIN 7991 countersunk screws and attach
interconnection metal plate to the pump with enclosed Allen key 2mm.
ATTENTION!
Pay special attention to
orientation of the
interconnection metal plate.
The screws head must be
aligned (flushed) with the
metal plate.
In order to connect the reservoir and
the pump please follow these steps:
1)
Install the provided gasket (o-
ring) into the milled groove as
shown on the picture below.
Failing to do this will cause
serious leakage.
2)
Use four enclosed M3x8 DIN
7991 (countersunk) screws and
attach pump to the reservoir
with enclosed Allen key 2mm.
CAUTION:
Be extremely careful not to overtighten the M3
screw. Doing this may strip the thread and
render product useless.
TROUBLESHOOTING:
-
If the threaded holes do not align
please re-check STEP 2 in the
manual.
-
If the screw head does not
align (flush) with the metal
plate please re-check STEP 2 in
manual.
O-ring
M3x8
screw