background image

 

 

 

     

Revision 1.1, Released on 15

th

 of April, 2016. 

 

Installation and mounting manual for EK-XRES 100/140 Revo 

D5 Series Reservoir 

This product is intended for installation only by expert users. Please consult with a qualified technician for installation. Improper installation may result in damage to your equipment. EK Water Blocks assumes no liability 

whatsoever, expressed or implied, for the use of these products, nor their installation. The following instructions are subject to change without notice. Please visit our web site at 

www.ekwb.com

 for updates. Before 

installation of this product please read important notice, disclosure and warranty conditions printed on the back of the box. 

 

Before you start using this product please follow these basic guidelines: 

1.

 

Please carefully read the manual before through before beginning with the installation process! 

2.

 

The EK HFB and EK-ACF type fittings require only a small amount of force to screw them firmly in place since the liquid seal is ensured by the rubber o-ring gaskets.

 

3.

 

The use of corrosion inhibiting coolants is always recommended for any liquid cooling system.

 

STEP 1:  PREPARING THE PUMP 

(already done by EK)

 

STEP 2: INSTALLING THE XRES D5  

(already done by EK)

 

Unscrew the ribbed threaded ring that attaches the Laing pump’s 
original factory top and the main pump core housing with motor. 
Store the original top, the original o-ring gasket and the attaching 
ring in a safe place. 

 

 

1.

 

Install the EK-XRES Revo D5 onto the pump main motor housing. 

Make sure you install EK 

provided 61x3mm o-ring gasket! 

Reseat the gasket if needed. 

You can rotate the pump and use it in any direction except upside-down to best suit your 

installation. 

2.

 

Secure the pump on the EK-XRES 100 Revo D5 using enclosed M74 Nut. 

 

STEP 2 (optional):  ADDITIONAL DAMPER

 

Additional Revo D5 Damper is enclosed. If pump vibrations are higher than expected additional Revo D5 Soft dumper can be used.  When replacing damper, take care that 
top pyramids are faced up as shown on picture below. In case of severe tilting of the computer chassis reservoir unit may fall out of the holder. Additional dumper use is 

recommended in vertical reservoir unit mount, see picture under STEP 4.

 

STEP 3 (optional):  USING POLYETHER ANTI-VORTEX FOAM or EK-HD Tube:

 

EK-XRES 100 Revo D5 series pump top / reservoir comes preinstalled with Anticyclone by default. In case your system suffers from excessive vortex issues, air bleeding 
problems or if the pump is sucking in air you may replace the anticyclone with the enclosed polyether foam or EK-HD Tube. There are two ways to use the polyether anti-

vortex foam: 

Default configuration 

PE foam – use whole 

PE foam – trim to fit recess 

HD Tube 

 

 

 

 

This is the default configuration of 
EK-XRES 100 Revo D5 

series

 

reservoir. 

Use the foam as a whole to replace 
the Anticyclone. 

Trim the foam to size to fit into the 
desired inlet recess on the EK-XRES 
Revo D5 main body. 

Insert enclosed o-ring 16x2 into the 
groove inside center hole and insert 
enclosed EK-HD Tube 12/16. 

 

Factory original 

pump top 

D5 pump body with 

motor 

EK-XRES D5 

61x3mm sealing gasket (OR) 

D5 pump body with motor 

NUT M74 

Twist LEFT to unscrew! 

Pump holder 

Rubber Damper 

Screws M3x12 

Revo D5 Soft Damper 

Top pyramids must be facing UP 