background image

- 13 -

To ensure the installation of EK components was successful, we 
recommend you perform a 24-hour leak test.

When your loop is complete and filled with coolant, connect the pump 
to a PSU outside your system. Do not connect power to any of the other 
components. Turn on the PSU and let the pump run continuously. 

Inspect all parts of the loop, and in case the coolant leaks, fix 
the issue and repeat the testing process. To prevent possible 
damage, please ensure that all hardware is dry before the system 
is powered on.

TESTING THE LOOP

REPLACING THE LED STRIP (Optional)

STEP 1

If you want to replace the D-RGB LED strip, you must remove the two 
(2) standoffs shown in the picture using a 6mm wrench. Remove the 
stickout and replace the LED strip.   

Once you have replaced the LED strip, align the holes on 
the stickout with holes on the top plate, and tighten the 
standoffs evenly.

STEP 1

Содержание EK-Quantum Vector RTX 3080/3090 D-RGB

Страница 1: ...USER GUIDE GPU WATER BLOCK EK Quantum Vector Trio RTX 3080 3090 D RGB...

Страница 2: ...B EK Fittings require only a small amount of force to screw them firmly in place since the liquid seal is ensured with the rubber O ring gaskets The use of quality market proven corrosion inhibiting c...

Страница 3: ...PADS 8 CLEANING THE PCB 8 APPLYING THERMAL COMPOUND 9 INSTALLING THE WATER BLOCK 10 PLACING THE BLOCK ON THE GRAPHICS CARD 10 ATTACHING THE BLOCK TO THE GRAPHICS CARD 10 CHECKING FOR CONTACT 11 INSERT...

Страница 4: ...Screw 13 pcs Allen Key 2 5 mm 1 pc Thermal Pad F 1 0 mm 5 pcs Thermal Grease 1 pc M2 5x8 AX1 Screw 2 pcs M2 5x4 AX1 Screw 20 pcs EK Quantum Vector Trio RTX 3080 3090 D RGB PVC Washer M2 5 20 pcs 120...

Страница 5: ...5 WATER BLOCK DIMENSIONS 105 62 mm 134 62 mm 319 43 mm 141 50 mm 156 90 mm 20 35 mm...

Страница 6: ...GB connector standard 3 pin 5V Data Blocked Ground M4x8 DIN7984 SCREW O RING 15x1 M4x20 DIN7984 SCREW TERMINAL COVER TERMINAL TOP PLATE PLEXI ACETAL COLDPLATE COLDPLATE INSERT PLEXI JET PLATE EK BADGE...

Страница 7: ...the EK Quantum Vector Trio RTX 3080 3090 D RGB water block on the graphics card Use the Phillips head screwdriver to remove the five 5 green marked screws from the GPU bracket side Then remove the fif...

Страница 8: ...120 x 16 mm EAN 3830046996732 STEP 1 Thermal Pad F 1 0 mm 120 x 16 mm CUTTING AND PLACING THERMAL PADS 120mm 16 mm 1 mm STEP 2 CLEANING THE PCB Carefully detach the original stock cooler after removin...

Страница 9: ...the entire surface of the IHS The excessive or uneven application of thermal grease may lead to poor performance STEP 1 APPLYING THERMAL COMPOUND For this Step you will need STEP 2 STEP 2 Once cut to...

Страница 10: ...ge to the GPU Always use a plastic washer under each screw For one 1 M2 5 screw marked with red triangle you will also need one 1 M2 5 Nut to succesfully attach bracket to pcb INSTALLING THE WATER BLO...

Страница 11: ...ecessary manipulation of the water block assembly that might damage your card or water block CHECKING FOR CONTACT If necessary temporarily remove the water block to check for uniform surface contact b...

Страница 12: ...ADER INSTALLATION OF FITTINGS AND TUBING STEP 1 Screw in two 2 G1 4 threaded male fittings Attach the liquid cooling tubes and connect the water block s to the cooling loop Do not forget to plug the r...

Страница 13: ...op and in case the coolant leaks fix the issue and repeat the testing process To prevent possible damage please ensure that all hardware is dry before the system is powered on TESTING THE LOOP REPLACI...

Страница 14: ...d assistance please contact https www ekwb com customer support EKWB d o o Pod lipami 18 1218 Komenda Slovenia EU EKWaterBlocks EKWaterBlocks ekwaterblocks ekwaterblocks EKWBofficial SUPPORT AND SERVI...