ekwb EK-DBAY D5 Скачать руководство пользователя страница 2

 

 

 

 

         Revision 1.1. Released on 4

th

 of June, 2014 

STEP 4:  INSERTING THE RESERVOIR TO YOUR COMPUTER CHASSIS 

 This reservoir occupies two (2) 5.25" drive bay expansion slots in your computer chassis. Free two slots in case they are already occupied with other 

computer  components  such  as  optical-  or  hard  disk  drives.  Place  the  reservoir  in  your  5.25"  drive  bay,  with  the  front  plate  facing  outwards. 

After

 completing 

STEP 6

 in this manual, secure the reservoir to the drive bay cage using the enclosed eight (8) M3x4 DIN 7985 screws with Philips 

head screwdriver.  

 

STEP 5:  CONNECTING YOUR RESERVOIR 

It is mandatory to use the correct INLET and OUTLET port.

 Please use the appropriate G1/4 threaded ports as shown on the picture below. EK 

recommends using EK-CSQ compression fittings for best water cooling experience.

 

 

 

 

 

 

 

STEP 6: FILLING THE RESERVOIR        

Fill the reservoir through G3/8 threaded fill port (marked 

with arrow) and make sure liquid is not spilled over your 

computer  or  any  electrical  devices  nearby.  Run  your 

pump  shortly  for  few seconds’  couple  of times to  make 

sure  water  floods  your  tubes  and  other  water  cooling 

components  before  permanently  leaving  the  pump  on. 

Pay attention to the water level in your reservoir. Lowest 

and  highest  recommendable  water  levels  are  indicated 

on  the  reservoir's  front  panel  (MIN,  MAX).  Once  done 
with  the  filling  process  please  close  your  EK-DBAY  D5 

reservoir  with  G3/8  plug  and  tighten  the  seal  using 

enclosed Allen key (6mm). Now secure the bay reservoir 

with M3x4 DIN 7985 screws mentioned in 

step 4

.

 

 

 

STEP 7:  OTHER INSTRUCTIONS  

VERY IMPORTANT NOTICE: 

Once the installation is completed, it is a recommended practice to test the cooling circuit for leaks prior to powering up the computer. We recommend a 24 hour leak test prior to powering 

up the computer. Do not test the water block using tap water pressure. This will rupture the top of the housing and render the block unusable (and will void your warranty).While all efforts have been made to provide the 
most comprehensive tutorial possible, EK Water Blocks assumes no liability expressed or implied for any consequential damage(s) occurring to your equipment as a result of using EK Water Blocks cooling products, either 
due to errors or omissions on our part in the  above instructions, or due to failure or defect in the EK Water Blocks cooling products. 

WARRANTY: 

Our products are warranted against defects in materials or workmanship for a period of 24 months beginning from the date of delivery to the final user. During this period, products will be repaired or have 

parts replaced at our discretion provided that: (I) the product is returned to the agent from whom it was purchased; (II) the product has been purchased by an end user and has not used for commercial purposes; (III) the 
product has not been misused, handled carelessly, or used in a manner other than in accordance with the instructions provided describing its installation and proper use. This warranty does not confer rights other than 
those expressly set out above and does not cover any claims for consequential loss or damage.  This warranty is offered as an extra benefit and does not affect your statutory rights as a consumer. This warranty is voided if 
the product comes in contact with aggressive UV additives or other improper liquids. 

 

REQUIRED TOOLS:

 

 

 

 

 

                                        

Philips head screwdriver

 

 

M3x4 DIN 7985 screw 

INLET

 G1/4 

threaded port 

OUTLET

 G1/4 

threaded port 

EK-CSQ 
compression fittings 

G 3/8 threaded fill port

 

MIN, MAX indicator 

Отзывы: