USER GUIDE

EK-Quantum 

Reflection Uni 140 D5 PWM D-RGB 

Содержание 3831109827406

Страница 1: ...USER GUIDE EK Quantum Reflection Uni 140 D5 PWM D RGB...

Страница 2: ...gaskets The use of corrosion inhibiting coolants is always recommended for any liquid cooling system EKWB recommends any of the EK Cryofuel for worry free usage There are many ways to install and conf...

Страница 3: ...NTS 4 MOUNTING INFORMATION 5 INSTALLING EK QUANTUM REFLECTION UNI 140 D5 PWM D RGB 6 RECOMMENDED CONFIGURATIONS 7 CONNECTING THE D RGB LED STRIP 10 CONNECTING THE PUMP 10 TESTING THE LOOP 11 SUPPORT A...

Страница 4: ...ENTS EK Quantum Reflection Uni 140 D5 PWM D RGB M4 x 8 Screw DIN7984 5 pcs M4 PVC Washer 5 pcs Allen Key 2 5 mm 1 pc EK Loop Multi Allen Key Bag content Bag content is universal you may not need all s...

Страница 5: ...ver it must always be mounted vertically to assist with filling and bleeding it is optimal to keep the pump in the lowest possible position as shown here Never mount or operate EK Quantum Reflection U...

Страница 6: ...D5 PWM D RGB Using the included M4 screws you can mount the Reflection UNI 140 directly to your chassis or any other 140mm fan mounting location EK Quantum Reflection UNI 140 D5 PWM D RGB M4 X 8 DIN 7...

Страница 7: ...g G1 4 plugs Using EK Quantum Reflection UNI 140 D5 PWM D RGB as a PUMP RES Combo When using the Reflection UNI 140 as a pump res combo in any orientation there is only one possible outlet port Two of...

Страница 8: ...Outlet ports A and B that are linked in series each pair may be used to connect one or multiple components in series or parallel as required Components in Set A must return to Inlet A where the coola...

Страница 9: ...9 INLET B INLET A INLET B DRAIN FILL OUTLET A FILL OUTLET B INLET B OUTLET B INLET B DRAIN FILL OUTLET A FILL INLET A...

Страница 10: ...PUMP The EK D5 PWM pump has two connectors 1 4 pin Molex It must be connected directly to your PSU at all times as it is used to power the pump 2 4 pin PWM fan It can be connected to your motherboard...

Страница 11: ...nect power to any of the other components Turn on the PSU and let the pump run continuously It is normal for the coolant level to drop during this process as air collects in the distribution plate Ins...

Страница 12: ...you need assistance please contact http support ekwb com EKWB d o o Pod lipami 18 1218 Komenda Slovenia EU EKWaterBlocks EKWaterBlocks ekwaterblocks ekwaterblocks EKWBofficial SUPPORT AND SERVICE SOCI...