Malfunction
Possible cause
Solution
Compressor does
not switch on
No voltage in the pressure switch
Check voltage in socket
Check circuit breaker switch
–
switch to position switched-
on „I“
Loose conductor from terminal -
repair
Check electrical cord
– replace
defective cord
Motor winding failure, damaged
thermal protection
Replace motor or windings
Capacitor failure
Replace capacitor
Seized piston or other rotating part
Replace damaged components
Pressure switch does not switch
Check function of pressure switch
Controller malfunction
Check controller operation, check to
ensure software is present - replace
if damaged or upload the correct
program
RUN/STOP
indicator is not
green
Loss of connection between
controller and expansion module
Check connection
– replace if
damaged
Power loss
Check mains voltage
Loose terminal in switchboard -
tighten
Check the primary power
connection - replace if damaged
Problem with electrical power
source
Main breaker is off
Controller or expansion module
malfunction
Replace failed controller or
expansion module
Compressor often
switches on
Air leakage in pneumatic system
Check pneumatic system
– seal
loose connections
Non-return valve (SV) leakage
Clean non-return valve, replace
seals, replace non-return valve
Leak through solenoid valves once
Clean the check valve - replace if
Содержание DK50 3x4VR/M
Страница 1: ...DK50 3x4VR M User manual ...
Страница 2: ......
Страница 13: ...PRODUCT DESCRIPTION 06 2022 13 NP DK50 3x4VR_M AD A EN 3_06 2022 Fig 2 Adsorption dryer ...
Страница 14: ...PRODUCT DESCRIPTION NP DK50 3x4VR_M AD A EN 3_06 2022 14 06 2022 Fig 3 Switchboard ...
Страница 23: ...INSTALLATION 06 2022 23 NP DK50 3x4VR_M AD A EN 3_06 2022 Fig 8 Connecting the dryer to the compressor IN OUT ...
Страница 30: ...INSTALLATION NP DK50 3x4VR_M AD A EN 3_06 2022 30 06 2022 14 PNEUMATIC DIAGRAM DK50 3x4VR M ...
Страница 60: ......
Страница 61: ......
Страница 62: ......
Страница 63: ......