PRODUCT MAINTENANCE
12/2021
25
NP-DO M-39_12-2021
Following works must be carried out from the hygiene and the correct suction
equipment function points of view.
14.2. Inlet Sieve Cleaning
Solid particles (sucked together with a liquid component and the air) are entrapped in the inlet sieve
(7) during the equipment operation which therefore must be regularly cleaned, by section 14.1
(though, always at the end of each shift).
The inlet sieve cleaning is possible only after the moisture inside suction tubings (6) and a sieve is
reduced by means of the several seconds lasting air suction through tubings taken off the holder
(2). Then turn the power-
supply switch (5) off in the position „O“ and slightly lift the cover of the inlet
sieve. Afterwards pull the sieve out of its place gripping the holder, remove solid particles and clean
the sieve. Then put the sieve on the previous place into the holder and carry out the assembly in
the contrary manner to the dismantling.
Danger of environmental pollution.
If the suction of amalgam particles is expected, it is necessary to empty the inlet
sieve content into a closable vessel and forward it to the collecting centres
according to local regulations.
14.3. Lubricating seals and sliding closures
O-rings (sealing rings) and sliding terminal clamps (Fig. 1) must be lubricated using a suitable
silicone oil for dental applications (e.g. Lubri-Jet spray) every 15 working days.
14.4. Disinfection of Tubings and Separation Vessel
For the separation vessel (11) disinfection it is necessary to empty the same, rinse with warm water
and clean mechanically with warm water and a disinfectant.
The disinfection of internal suction tubings and of the separation vessel should be performed by
section 14.1, though always at the end of a shift by suction of warm water containing a disinfectant
having a limited foaming power through both suction tubings (6) separately. The used disinfectant
must be approved in compliance with a valid national legislation on usage for disinfected surface
and a type of material.
For the disinfectant use, follow the maufacturer’s instructions.
14.5. Cleaning and disinfection of the exterior surfaces of the product
Use neutral agents for cleaning and disinfection of the external surfaces of the product.
The use of aggressive cleaning agents and disinfectants comprising alcohol and
chlorides may lead to the damage of the surface and the discoloration of the
product.
To find out whether the suction equipment works correctly, the following works should be carried
out in the defined maintenance intervals:
14.6. Replacement of the Output Pre-filter
It is necessary to replace the output pre-filter (15) by section 14.1. Before making any replacements
turn the suction equipment power-supply switch (5) off. The pre-filter together with the filter (14) are
situated on the left lower part of the suction equipment
’s base.
For its dismantling, catch the filter holder (13) with one hand and with the other hand slew the fixing
lugs (16) by 90° by simultaneous pulling down. Remove the filter holder together with the output
Содержание ASPINA DO M
Страница 2: ......
Страница 4: ...CONTENTS 5 INHALT 31 TABLES DES MATI RES 57 83 SPIS TRE CI 110 OBSAH 136 OBSAH 162...
Страница 11: ...PRODUCT DESCRIPTION 12 2021 11 NP DO M 39_12 2021 Fig 1 Mobile dental suction equipment ASPINA DO M...
Страница 37: ...PRODUKTBESCHREIBUNG 12 2021 37 NP DO M 39_12 2021 Abb 1 Mobile dentale Absaugeinheit ASPINA DO M...
Страница 63: ...DESCRIPTION DU PRODUIT 12 2021 63 NP DO M 39_12 2021 Fig 1 L aspirateur dentaire mobile ASPINA DO M...
Страница 84: ...NP DO M 39_12 2021 84 12 2021 93 42 EEC MDD DO M CE...
Страница 85: ...12 2021 85 NP DO M 39_12 2021 B 5 1...
Страница 86: ...NP DO M 39_12 2021 86 12 2021 5 2 5 3...
Страница 87: ...12 2021 87 NP DO M 39_12 2021...
Страница 88: ...NP DO M 39_12 2021 88 12 2021 6 1 25 55 C 24 70 C 90...
Страница 90: ...NP DO M 39_12 2021 90 12 2021 1 ASPINA DO M...
Страница 91: ...12 2021 91 NP DO M 39_12 2021 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18...
Страница 93: ...12 2021 93 NP DO M 39_12 2021 o IEC 60601 1 2 2014 1 2 o CISPR 11 1 CISPR 11 B IEC 61000 3 2 IEC 61000 3 3...
Страница 96: ...NP DO M 39_12 2021 96 12 2021 5 C 40 C 10 C 25 C 40 C 32 C...
Страница 97: ...12 2021 97 NP DO M 39_12 2021 230 11 10 13 5 I 3 11 16 14 8...
Страница 98: ...NP DO M 39_12 2021 98 12 2021 12 1 Aspina DO M 1 2 3 4 5 6 7 8...
Страница 100: ...NP DO M 39_12 2021 100 12 2021 5 I 6 1 2 11 6 10 9 4 10 8 1 12 13 1 17 7 5 O...
Страница 101: ...12 2021 101 NP DO M 39_12 2021 13 2 13 1 1 2 7 14 8 14 8 100 B IEC 60601 1...
Страница 102: ...NP DO M 39_12 2021 102 12 2021 24 EN 62353 EN 62353 G CE...
Страница 104: ...NP DO M 39_12 2021 104 12 2021 14 2 7 1 14 1 6 2 5 O 14 3 1 Lubri Jet 15 14 4 11 1 14 1 6 14 5...
Страница 106: ...NP DO M 39_12 2021 106 12 2021 C PP PP 45 C EN ISO 15883 CE 93 42 CEE EN 13060 EN 285 EN ISO 17665 1 B 134 C 5 10 100...
Страница 107: ...12 2021 107 NP DO M 39_12 2021 14 9 1 2 3 2 14 2 14 4 I 15 20 O 14 1...
Страница 108: ...NP DO M 39_12 2021 108 12 2021 14 I o 2 T 6 3 A...
Страница 109: ...12 2021 109 NP DO M 39_12 2021 14 1 14 1...
Страница 116: ...OPIS PRODUKTU NP DO M 39_12 2021 116 12 2021 Rys 1 Mobilna odsysarka dentalna ASPINA DO M...
Страница 142: ...POPIS V ROBKU NP DO M 39_12 2021 142 12 2021 Obr 1 Mobiln dent lna ods va ka ASPINA DO M...
Страница 168: ...POPIS V ROBKU NP DO M 39_12 2021 168 12 2021 Obr 1 Mobiln dent ln ods va ka ASPINA DO M...
Страница 191: ...ANNEX ANHANG ANNEXE ZA CZNIK PR LOHA P LOHA 12 2021 191 NP DO M 39_12 2021 1 DO M 2 3 1 3 2 4 5 6 7 8 9 5 6 5 6...
Страница 195: ......