The higher power output rating of this stove is based on around 1.4kg of seasoned logs which would require
refuelling every hour.
This stove is suitable for intermittent burning, and should not be used constantly for extended periods. Not suitable
for overnight burning.
Under certain abnormal weather conditions, e.g. down draughts, it may be difficult to get sufficient draw through the
appliance to achieve good combustion. When this happens, the stove should not be used.
IMPORTANT: -
As of October 2010, it is a legal requirement to use a Carbon Monoxide Detector in the same room as the stove. This
needs to incorporate a battery which lasts the life of the detector.
CLEANING/MAINTENANCE
Regular cleaning of the stove is essential for safety and efficiency. The ash-pan should be emptied at least after every
use, and during use if burning for longer periods.
When cold, the inside of the stove should be given a regular sweep out.
The flue and flue pipe will require cleaning with a suitable chimney brush, to minimise build up of soot and tar.
Your chimney will also require periodic sweeping.
If the glass becomes stained from the inside, the air-wash vent may need opening more during use.
The high temperature paint which your stove is finished in should last many years with normal use, but when it does
eventually require re-finishing, black heat resistant paint in spray cans can be purchased from most hardware stores. –
Do not use regular paint which is not high temperature resistant.
After prolonged periods of not using the fire, the stove and flue system should be checked for blockages prior to re-
lighting.
We recommend regular servicing and safety checks are carried out by a qualified engineer.
There must be no unauthorised modification of the appliance. Use only replacement parts recommended by the
manufacturer.
MODELS WITH MIRROR GLASS: THIS GLASS HAS A SPECIAL COATING, DO NOT USE ANY ABRASIVE
MATERIAL TO CLEAN THE GLASS. Just use a clean cloth with warm water.
GUARANTEE
The main body of your stove is guaranteed for 12 months. This does not include glass, grates, door seals, over-firing
incorrect use or installation not carried out by a competent person or in accordance with building regulations. – You
should have zero problems with your stove unless it is abused and if treated well your stove will last and last.
What to do in the event of a chimney fire:-
cut off the air supply to the stove, i.e. close the primary and secondary air supplies
move any combustible materials well-away from the stove
get everyone out safely
make sure that the fire brigade has clear access
call 999
If you have any questions or concerns regarding the safe use of your stove, please contact us: -
Ekol Stoves, Station Works, John’s Road, Wareham, Dorset, BH20 4BG
01929 555211
[email protected]