5) Use the M6 studs from underneath to level the stove 

horizontally using an allen key. 

See figure 5.1

As you tighten the stud, the two tab brackets on the plate 

and stove respectively, will move away from each other 

slightly, thus raising that side of the stove.

If necessary, washers can be used between the tabs to 

maintain close larger gaps when leveling the stove.

6) Using the M8 bolts located at the bottom left and right 

hand corners of the wall plate, the stove can be aligned 

vertically. By loosening each bolt anti-clockwise, the bottom 

of the stove will move away from the wall, thus providing 

this vertical adjustment if necessary. 

See figure 5.2

7) When fitting flue pipe using the top exit on the stove, 

ensure that the weight of the flue system is self supported 

(the flue system should not be supported by the stove 

itself).

template pages please retain

page

18

Figure 5.1

Figure 5.2

Содержание Adept

Страница 1: ...GH QUALITY SEASONED LOGS OR HIGH QUALITY SUITABLE DOMESTIC HEATING BIOETHANOL FUEL IS TO BE BURNT ON THIS APPLIANCE DEPENDENT ON MODEL VERSION NEVER ATTEMPT TO BURN RUBBISH Please read instructions ca...

Страница 2: ...ecords Warranty Information 3 4 5 8 8 9 10 12 15 14 15 15 16 17 17 18 19 20 21 When purchased new from an Authorised Ekol Retailer your new adept stove includes an Extended 10 year limited warranty De...

Страница 3: ...inset stove Suggested Clearances to Non combustible materials 30mm all round to suitably thick solid materials Minimum Clearances to Combustible materials Rear of stove 200mm as a free standing stove...

Страница 4: ...aces on the stove from moving or installation can be touched up using suitable high temperature stove paint Thankyou for choosing the Ekol Adept We are confident that your new stove will provide many...

Страница 5: ...These inlets allow fresh air to reach the upper parts of the firebox allowing rising smoke and gases to re ignite and burn thoroughly and cleanly before escaping out into the flue To increase the flo...

Страница 6: ...nderneath of the stove creating a cyclical warm air movement Once the appliance has been correctly installed it is ready for the first fire We would encourage even experienced stove users to follow th...

Страница 7: ...eration of the airwash system 17 If the bed of embers builds up too much allow it to burn down a bit before refueling 18 If there is a delay when refueling and the bed of embers has mostly burnt throu...

Страница 8: ...ly cool if burning wood the stove must be first allowed to completely extinguish and cool to room temperature before attempting to insert and use the Bioethanol burner 7 Fuel should only ever be poure...

Страница 9: ...le in the bottom of the reservoir 7 Place the combustion block back into its outer tray inside the stove 8 Using a long lit match or long lighter carefully ignite the fuel by placing the lighter into...

Страница 10: ...ve all around over time the rope will flatten out and loose some flexibility when this happens and when it is no longer sealing fully all the way round it needs to be replaced The rope size used here...

Страница 11: ...by Scottish Ministers under section 50 of the Regulatory Reform Scotland Act 2014 In Northern Ireland applianc es are exempted by publication on a list by the Department of Agriculture Environment an...

Страница 12: ...fitted when using the external outside air supply option Flue Outlet The stove has the option of having a top or rear flue outlet There are three components which require fitting into their correct p...

Страница 13: ...m 12mm thick needs to extent at least 150mm either side of the appli ance and at least 225mm in front of the appliance The distance in front of the stove should be increased when the appliance is in a...

Страница 14: ...ecommend the use of ducting more than 3 metres When using flexible ducting less than 80mm diameter the ducting should be inserted into the connector on the back of the stove figure 3 4 1 Apply a layer...

Страница 15: ...ible Pink fire resistant plasterboard is NOT suitable and should never be used for constructing walls adjacent to fireplaces 3 The Adept stove when used in an inset situation can be low down close to...

Страница 16: ...required 11 Whichever type of flue system and connecting pipes are used a method of releasing the flue from the stove without dismantling the entire flue system should be considered This could for exa...

Страница 17: ...estal to raise itself a few millimetres off the ground ensuring the door has ground clearance to slide open and to allow for any small level discrepancies of the hearth Put these pads close to each co...

Страница 18: ...larger gaps when leveling the stove 6 Using the M8 bolts located at the bottom left and right hand corners of the wall plate the stove can be aligned vertically By loosening each bolt anti clockwise t...

Страница 19: ...set of 4 Vent slider controls Standard inner glass Vent slider actuators Rear fire bricks set of 2 Removable cool touch handle multi function tool Front log retaining bars Tertiary air introduction i...

Страница 20: ...ERVICE Date of Service Next Service Due Details of Service work completed Signed Dealer s Stamp HETAS Registration Number 6th SERVICE Date of Service Next Service Due Details of Service work completed...

Страница 21: ...firebricks glass baffle plates log retaining bars paint and surface finishes door and glass rope seals 3 Damage caused by incorrect use incorrect non recommended fuel over firing or poor maintenance w...

Страница 22: ...orset UK BH20 4BG enquiries defrastoves com 01929 555211 80mm 5 125mm flue outlet Top or rear connection 145mm 184mm 330mm 121mm 57mm 220mm 280mm 451mm 500mm 385mm 346mm External air supply for either...