25
Fault indicator light 9. Lifting lock indicator light 10. Foot switch indicator light 11. Battery alarm lamp
9.2 the battery
First use an inner hexagonal wrench to unscrew the screw, take out the battery baffle, and then slowly
pull out the battery from the side to replace, to ensure that the lifting equipment has enough load
capacity.
The lifting device must be pulled vertically to avoid damage to the battery case.
The hook of the
lifting device must be safe and reliable. The hook must not fall on a single cell in the battery pack.
- Press the emergency stop switch and power key switch to the OFF position so that it is in the cut OFF
position.
- Remove the connector of the battery cable.
14. CURTIS Handheld unit
Precautions for operation:
The attention function of the hand-held unit is to facilitate vehicle inspection and maintenance. It is not
allowed to adjust the controller parameters without the approval of the vehicle manufacturer, to avoid
vehicle and personal safety accidents.
The hand-held unit will automatically save the modification parameters, just need to close the key switch,
restart.
The CURTIS handheld unit can be connected in the event of a controller power or power failure
Содержание EK18RF
Страница 6: ...5 Pic2 The rail of gantry Pic3 Drive axle clamp...
Страница 15: ...14 9 Wiring circuit diagram A Electrical schematic diagram 3 2 hydraulic principle diagram...
Страница 18: ...17 12 The braking system Operating handle diagram...
Страница 21: ...20 1 solenoid valve 2 proportional valve 3 check valve 4 countercurrent valve 5 throttle valve...
Страница 22: ...21 13 Schematic drawing of lifting cylinder and tilting cylinder...