background image

5

Status LED
The meaning of the status LED under the programming 

button is as follows:

• 

Green steady on: normal operation and DALI line pre

-

sent

• 

Flashing green: no DALI line

• 

Flashing red: generic error on the output

If the programming button is not pressed within 1 minute, 

the  status  LED  goes  into  standby. A  short  press  of  the 

programming button turns the LED back on and shows 

the status.

Configuration change
Subsequently, it is possible to change the device confi

-

guration  and  addressing  using  an  application  for  para

-

meterization,  for  example  by  downloading  the  ekinex 

CGEKBG1TP software to the PC which allows you to:

• 

configure the DALI system and define its parameters;

• 

set the DALI devices (groups, scenarios, IDs, etc.);

• 

test the communication on the DALI bus;

• 

update the device.

The software can be downloaded from the website www.

ekinex.com and its use is described in the application ma

-

nual of the ekinex EK-BG1-TP DALI Gateway. The sof

-

tware works with Microsoft Windows (7 and later).

DT6 with single output channel

DT6 with 2 independent output channels

DT8 with single Tunable White output channel

DALI System fail function
For each device it is possible to set the “system failure” 

parameter, that is the brightness level at which the LED 

load is set, in case of DALI bus outage.

This setting can be done using a DALI programmer such 

as USB DALI interface Tridonic, Lunatone DALI Cockpit 

or similar.

The range of brightness values is from 0 to 254 (100%).

If the value 255 (MASK) is set, the last brightness value 

is restored.

Note. 

For the CGEKBG1TP configuration software 

to work, it may be necessary to install .NET Fra-

mework 4, which can be downloaded freely from the 

Microsoft website.

i

Содержание EK-GD2-DL-1-LV

Страница 1: ...a single DT6 output channel 2 single DT6 channels or a single chan nel in TW DALI DT8 mode DT6 DT8 setting for EK GD2 DL 2 LV model is done via local selector switch The devices have an integrated bus communication module DALI 2 certified Technical data Inputs Input constant voltage 12 48 Vdc Supply voltage min 10 8 Vdc max 52 8 Vdc Power absorbed while awaiting command 500 mW for EK GD2 DL 1 LV o...

Страница 2: ...k or DT6 DT8 selector 5 PUSH N O pushbutton pole 1 PUSH N O pushbutton pole 2 EK GD2 DL 1 LV only EK GD2 DL 2 LV only Accessory for 1 CH and 2 CH models Rail mounting support The devices EK GD2 DL 1 LV and EK GD2 DL 2 LV can be mounted on 35 mm rail according to EN 60715 with the plastic support included in the delivery Control signaling and connection elements The devices are equipped with screw ...

Страница 3: ...hort circuit protection only and the power must be correctly dimensioned In case of usage of a po wer supplier with ground terminals all points of the pro tective earth PE Protection Earth must be connected to a valid and certified protection earth Insert the mounting support in the appropriate shaped profile of the back side of the device then hook the teeth to the profile guide starting from the...

Страница 4: ...ue to indicate the programming of the outputs as 2 single channels DALI DT6 pressing the button again will cause the yellow LED to light up indicating that the programming of the outputs is in Tunable White dynamic white with 1 DALI DT8 channel with a long press of at least 5 s the configuration is saved and the menu is exited after 60 s without further pressing the programming key the device exit...

Страница 5: ...n on the DALI bus update the device The software can be downloaded from the website www ekinex com and its use is described in the application ma nual of the ekinex EK BG1 TP DALI Gateway The sof tware works with Microsoft Windows 7 and later DT6 with single output channel DT6 with 2 independent output channels DT8 with single Tunable White output channel DALI System fail function For each device ...

Страница 6: ...ranty period In case of tampering the compliance with the essential requirements of the applicable directives for which the device has been certified is no longer guaranteed ekinex defective devices must be returned to the ma nufacturer at the following address Ekinex S p A Via Novara 35 I 28010 Vaprio d Agogna NO Italy Other information The instruction sheet must be delivered to the end cu stomer...

Отзывы: