4.6
LAN RS-485 converter
4.6.1
Function of the converter
For certain activities, the converter sends a defined data packet in the UDP protocol on the RS-485
bus via the Ethernet network. A receiver (data sink) can interpret this data packet and set a
defined event. The converter supports three protocol types: rare, home, and multi. Configuration of
the protocol type and the network settings is carried out using the
ekey home converter LAN config
software.
The converter functions in conjunction with the following ekey control panels:
□
ekey home CP WM 1
□
ekey home CP WM 3
□
ekey home CP IN 1
□
ekey home CP IN 2
□
ekey home CP DRM 1
□
ekey home CP DRM 2
□
ekey multi CP DRM 4
4.6.2
Controls and visual signals on the converter
1
Status LED
2
Button
3
10/100 LED
4
Link/activity LED
Fig. 2: Overview of
ekey home CV LAN RS-485
The converter has two status LEDs for displaying operating statuses. Two LEDs on the RJ45 socket
for displaying network statuses. There is a button for restarting the device/resetting the device to
its default settings.
Button operation
Function
Press and hold button for
>0.3 sec.
The converter is restarted.
Press and hold button for
>10 sec.
Reset to default settings.
Table 1: Button operation of
ekey home CV LAN RS-485