background image

Rear Panel Controls

5

1. AC INLET

   The terminal is connected to AC Input cord.

2. AC FUSE (AC 5A/ 250V)

   Replace it with the same type fuse when it is blown out.

3. DC 24V INPUT TERMINALS

   These terminals are for connecting DC power supply of battery.
   Connect red colored terminal to positive lead of battery 
   and black colored one to negative lead of battery.

4. SPEAKER OUTPUT TERMINALS

   These terminals are for connection of speaker lines to deliver power output 
   to speakers. Impedance (Voltages) of 4ohm, 8ohm, 70V and 100V
   is provided for convenience.

5. HIGH-PASS FILTER SWITCH

   This switch is for activating the High-pass Filter circuit to protect speaker
   from excessive low frequency power demands.
   The -3dB frequency of the High-pass filter is 400Hz.

6. INPUT LEVEL CONTROL

   This is used for volume level of Input.

7. SIGNAL INPUT JACK ( for 1/4 Phone Jack)

   This input jack is for balanced input signal. 

8. SIGNAL INPUT JACK (for XLR Receptacles Jack)

   This input jack is for balanced input signal. 

4

                              8

                              7 0 V                               1 0 0 V

  4 0 V                                             5 7 V                                                 1 2

                          2 5

AC INPUT

AC FUSE

F5AL 250V

OUTPUT RMS 400W

OUTPUT RMS 400W

COM

4

(40V)

8

(56.6V) (12.3 )

(25 )

70V

100V

ON

OFF

400Hz -3dB

HPF

INPUT LEVEL

BALANCED INPUT : 0dBm (775mV) / 20K

BALANCED INPUT : 0dBm (775mV) / 20K

MIN

MAX

DC INPUT

24V

50/60Hz. 1KW

220V-240V

TO REDUCE THE RISK OF FIRE

OR ELECTRIC SHOCK DON'T EXPOSE THIS
EQUIPMENT TO RAIN OR MOISTURE.

WA R N I N G

:

TO REDUCE THE RISK OF FIRE

TO REDUCE THE RISK OF FIRE

REPLACE ONLY WITH SAME TYPE FUSE.

CAUTION

:

CAUTION

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

RISK OF ELECTRIC SHOCK

DO NOT OPEN

MADE  IN  KOREA

MADE  IN  KOREA

PUBLIC ADDRESS

PUBLIC ADDRESS

www.ekars.co.kr

 POWER AMPLIFIER

 POWER AMPLIFIER

OUTPUT POWER 400W RMS

OUTPUT POWER 400W RMS

MODEL NO : EPA-2403

MODEL NO : EPA-2403

SN

LINK

LINK

1

2

3

4

5

6

7

8

Содержание EPA-2403

Страница 1: ...OPERATING MANUAL EPA 2403 Public Address Power Amplifier ...

Страница 2: ...The Speaker 6 6 Connections 7 7 Specifications 8 1 SamHyoung Electronics Co Ltd 936 4 Kumuncheoun Ri Hyangnam Myun Hwaseong City Kyunggi Do Korea 445 922 Tel 82 31 432 5112 82 31 432 4422 Fax 82 31 352 7637 82 31 352 7649 Home Page http www ekars co kr http www samhyoung co kr E mail export ekars co kr trade ekars co kr ...

Страница 3: ...ord receptacle or other outlet unless the blades can be fully inserted to prevent blade exposure CAUTION Although it is neither complicated to install nor difficult to operate your Power Amplifier a few minutes of your time is required to read manual for a properly wired installation and becoming familiar with its many features and how to use them Please take a great care in unpacking your Power A...

Страница 4: ...rotect against thermal run away MUTE START SYSTEM To protect speakers and remove pop noise start operating after 1 second BALANCED INPUT To allow you to build reliable system a balanced input is provided to reduce hum pickup from a long distance input cable and to avoid group loop problems USE OF EMERENCY BATTERY You can operate the power amplifier by using emergency battery for unexpected AC powe...

Страница 5: ...G LED This LED indicates power is turned ON 3 OUTPUT LEVEL INDICATORS These LEDs indicates the output level of this amplifier 4 PROTECTION INDICATOR This LED indicates the condition of the protection circuit When the protection LED is ON the amplifier is not operating normally overheating please check the INPUT OUTPUT condition of the amplifier ...

Страница 6: ...olume level of Input 7 SIGNAL INPUT JACK for 1 4 Phone Jack This input jack is for balanced input signal 8 SIGNAL INPUT JACK for XLR Receptacles Jack This input jack is for balanced input signal 4 Ω 8 Ω 7 0 V 1 0 0 V 4 0 V 5 7 V 1 2 Ω 2 5 Ω AC INPUT AC FUSE F5AL 250V OUTPUT RMS 400W OUTPUT RMS 400W COM 4Ω 40V 8Ω 56 6V 12 3 Ω 25 Ω 70V 100V ON OFF 400Hz 3dB HPF INPUT LEVEL BALANCED INPUT 0dBm 775mV ...

Страница 7: ...ing of the amplifier by connecting more speakers than the unit is rated for If you are in doubt please consult a professional installer OUTPUT RMS 400W OUTPUT RMS 400W COM 4Ω 40V 8Ω 56 6V 12 3 Ω 25 Ω 70V 100V OUTPUT RMS 400W OUTPUT RMS 400W COM 4Ω 40V 8Ω 56 6V 12 3 Ω 25 Ω 70V 100V OUTPUT RMS 400W OUTPUT RMS 400W COM 4Ω 40V 8Ω 56 6V 12 3 Ω 25 Ω 70V 100V OUTPUT RMS 400W OUTPUT RMS 400W COM 4Ω 40V 8Ω...

Страница 8: ...OPEN RISK OF ELECTRIC SHOCK DO NOT OPEN MADE IN KOREA MADE IN KOREA MONITOR PANEL MONITOR PANEL POWER CONSUMPTION 14W POWER CONSUMPTION 14W PUBLIC ADDRESS PUBLIC ADDRESS MODEL NO EPM 2082 MODEL NO EPM 2082 www ekars co kr SN FUSE FUSE REMOTE IN DC IN DC FUSE F300mAL 250V MUTE LEVEL CHIME LEVEL MIC 5 LEVEL MIN MAX MIN MAX MIN MAX AC FUSE F100mAL 250V AC INPUT REMOTE PRE1 PRE2 CHIME AUX REC TAPE CDP...

Страница 9: ...ncy Response 80 Hz 17KHz 3 dB S N More than 85dB High Pass Filter Switch ON 3dB at 400Hz Power Requirements AC 220V 240V 50 60Hz DC 24V Power Consumption Net Weight kg lb 1000Watts 20 44 0 Dimensions 483 W x 133 H x 300 D mm 19 W x 5 2 H x 11 8 D inch 8 Specifications and design are subjected to change without notice for improvements ...

Страница 10: ...Memo 9 ...

Страница 11: ...Memo 10 ...

Страница 12: ...618 Shihwa Industrial Complex 1378 Jungwang Dong Shiheung City Kyunggi Do Korea 429 450 Tel 82 31 432 5112 82 31 432 4422 Fax 82 31 432 5450 82 31 431 1690 E mail export ekars co kr trade ekars co kr Home Page http www ekars co kr http www samhyoung co kr Headquarter Overseas Dep MEMO PUBLIC ADDRESS TOTAL SOLUTION ...

Отзывы: