E
13
2
SCREEN ADJUSTMENT
Set-up Procedure
1) First, make the appropriate settings for the PC.
2) Select VESA DPMS icon in the ScreenManager’s PowerManager menu.
3) Select “On”.
Power saving method of VESA DPMS and the monitor
VESA DPMS utilizes four signals: ON, STAND-BY, SUSPEND, and OFF. The
monitor detects these signals from the graphics board and executes power-saving
accordingly, as shown in the table below.
Signal
Screen
LED
Power consumption
ON
Operation
Green
110 W (normal)
STAND-BY
Blank
Green
80% of normal
SUSPEND
Blank (Mode 1)
Flashing green
less than 10 W
OFF
Blank (Mode 2)
Yellow
less than 3 W
Off Timer
What is Off Timer?
The Off Timer function allows the user to set the time in which the monitor
will be in operation, called the “On Period” and automatically shifts the
operation into the “Off Timer Mode” when the set “On Period” expires. The
energy consumption of the monitor in the “Off Timer Mode” is as low as the
one of the monitor in “PowerManger Mode 2” although no setting PC to
operate the Off Timer function is required.
Set-up Procedure
(1) Select the “Off Timer” icon.
(2) Select “Enable”.
(3) Press the right/left key to adjust how long (1 to 23 hours) the monitor should
be in the “On Period”.
Advance notice (LED flashing green) will be given 15 minutes before the monitor
automatically enters the “Off Timer Mode”.
To Delay Entering the “Off Timer Mode”
To delay entering the “Off Timer Mode”, press any keys on the front panel
located to the left of the power switch during the “Advance notice Mode”. The
monitor will continue to operate for an additional 90 minutes. There will be
another advance notice for 15 minutes as described. Delayed entrance into the
“Off Timer Mode” can be extended as many times as desired.