background image

Makes images on dark backgrounds 
appear more vivid, brings out the 
subtle differences in similar shades 
of color, and ensures that colors 
retain their richness even in brightly 
lit rooms.

Outstanding Contrast Ratio

At startup or upon wakeup, the EIZO patented drift correction function 
quickly stabilizes the brightness level. In addition, a sensor measures the 
backlight brightness and compensates for brightness fluctuations caused 
by the ambient temperature and the passage of time.

Brightness Stabilization

Wide Viewing angles with 
minimal color shift when 
viewed from the side.

Wide Viewing Angles

178°

Image viewed from the side

Low Contrast (Image)

High Contrast (Image)

Calibration compliant with the DICOM Part 14 standard.
Ideal for viewing patient charts with MRI and CT medical images.

54 cm   [ 21.3" ]  COLOR  LCD  MONITOR

4

48 cm   [ 19" ]  COLOR  LCD  MONITOR

This brightness stabilization function is EIZO patented technology 
(Japan patent numbers 3171808 and 3193315, US patent number 6188380).

Backlight

Sensor

Main Board

Backside
of Panel

Hole for
Light
Transmission

Minutes

Brightness

With Brightness stabilization

Without Brightness stabilization

Preset Value

Содержание FlexScan MX-Series

Страница 1: ...Clinical Review Monitors...

Страница 2: ...s With the bundled RadiCS LE quality control software installed a self diagnosis function using a built in backlight sensor periodically checks the brightness of FlexScan MX Series monitors When a cha...

Страница 3: ...onitors Bezel Less More Comfortable Working Space with Widescreen DUE for Brightness Uniformity 4 Megapixel Bezel Less Widescreen With a 16 10 aspect ratio you can view patient charts and DICOM medica...

Страница 4: ...of time Brightness Stabilization Wide Viewing angles with minimal color shift when viewed from the side Wide Viewing Angles 178 Image viewed from the side Low Contrast Image High Contrast Image Calibr...

Страница 5: ...ent The height and pivot adjustable stand offers added flexibility and viewing comfort Backlight Saver with Screen Saver Backlight Saver with Viewer Application By setting the Backlight Saver function...

Страница 6: ......

Страница 7: ...X1 sold separately enables you to perform basic quality checks necessary for clinical review monitors In addition high performance calibration compliant with the DICOM Part 14 standard corrects the fl...

Страница 8: ...IZO carries out evaluations based on these guidelines EIZO Eco Products A Commitment to Environmental Preservation over the Product Life Cycle EIZO Eco Products 2006 Requirements Environment Awareness...

Страница 9: ...0 x 1200 61 Hz Frame synchronous mode 59 61 Hz Digital 162 MHz Analog 202 5 MHz Digital DVI Standard 1 0 Analog RGB Analog Separate Composite DVI I 29 pin 2 1 upstream 2 downstream Standard Rev 2 0 AC...

Страница 10: ...Copyright 2009 EIZO NANAO CORPORATION All rights reserved 090103 Printed in Japan 1 2009 3 5K...

Отзывы: