44
Chapter7Troubleshooting
7-4. Built-in correction sensor and SelfCorrection
problems
Problem
Possible cause and remedy
1. The built-in correction sensor does not
come out/stays out.
• Turnoffthemainpower,andthenturnitonagainafew
minuteslater.
2. SelfCorrection cannot be executed.
• CheckwhethertheColorNavigatorlicenseiscertified.
(See
“TouseColorNavigator/ColorNavigatorElements”
.)
• SettheSelfCorrectiontargetusingColorNavigatoror
ColorNavigatorElements.
3. SelfCorrection failure
• Refertotheerrorcodetable.Ifanerrorcodethatdoes
notappearintheerrorcodetableisdisplayed,contact
yourlocalEIZOrepresentative.
Error Code Table
Error Code
Description
0014
• ExecuteSelfCorrectionagain.
• AdjustusingColorNavigatororColorNavigatorElements.
0034
• Thebuilt-incorrectionsensormaynothavecomeoutduringcalibration,orlightmay
haveenteredthesensorduringmeasurement.
• Turnoffthemainpower,waitforafewminutesbeforeturningthepowerbackon,and
thenexecuteSelfCorrectionagain.
0050
• ExecuteSelfCorrectionagain.
0061
• Thebuilt-incorrectionsensormaynothavecomeout.
• Checkwhetherthereisanyforeignobjectnearthebuilt-incorrectionsensor.
• ExecuteSelfCorrectionagain.