1. The appliance is for indoor use only. 

2. Do not use the unit on a socket under repairs or not installed properly.

3. Do not use the unit, follow these precautions: 

A: Near to source of fire. 

B: An area where oil is likely to splash.

C: An area exposed to direct sunlight.  

D: An area where water is likely to splash. 

E: Near a bath, a laundry, a shower or a swimming pool. 

4. Never insert your fingers, rods into the air outlet. Take special care to warn 

children of these dangers.

5. Keep the unit upward while transport and storage, for the compressor locates 

properly. 

6. Before cleaning the air-conditioner, always turn off or disconnect the power 

supply. 

7. When moving the air-conditioner, always turn off and disconnect the power 

supply, and move it slowly. 

8. To avoid the possibility of fire disaster, the air-conditioner shall not be 

covered. 

9. All the air-conditioner sockets must comply with the local electric safety 

requirements. If necessary, please check it for the requirements.

10. Children should be supervised to ensure that they do not play with the 

appliance.

• The appliance must be stored in such a way as to prevent mechanical failure.
• Individuals who operate or work on the refrigerant circuit must have the 

appropriate certification issued by an accredited organization that ensures 

competence in handling refrigerants according to a specific evaluation 

recognized by associations in the industry.

• Repairs must be performed based on the recommendation from the 

manufacturing company. Maintenance and repairs that require the assistance of 

other qualified personnel must be performed under the supervision of an 

individual specified in the use of flammable refrigerants.

3

11. If the supply cord is damaged, it must be replaced by the manufacturer, its 

service agent or similarly qualified persons in order to avoid a hazard.

12. This appliance can be used by children aged from 8 years and above and 

persons with reduced physical, sensory or mental capabilities or lack of 

experience and knowledge if they have been given supervision or instruction 

concerning use of the appliance in a safe way and understand the hazards 

involved. Children shall not play with the appliance. Cleaning and user 

maintenance shall not be made by children without supervision.

13. The appliance shall be installed in accordance with national wiring 

regulations.

14. Details of type and rating of fuses

T, 250V AC,2A.

15. Recycling

    This marking indicates that this product should not be disposed with other 

household wastes throughout the EU. To prevent possible harm to the 

environment or human health from uncontrolled waste disposal, recycle it 

responsibly to promote the sustainable reuse of material resources. To return 

your used device, please use the return and collection systems or contact the 

retailer where the product was purchased. They can take this product for 

environmental safe recycling.

16. GWP: R290: 3

17. Contact authorized service technician for repair or maintenance of this unit.

18. Do not pull , deform . or modify the power supply cord , or immerse it in 

water . Pulling or misuse of the power supply cord can result in damage to the 

unit and cause electrical shock.

19. Compliance with national gas regulations shall be observed.

20. Keep ventilation openings clear of obstruction.

21. Any person who is involved with working on or breaking into a refrigerant 

circuit should hold a current valid certificate from an industry-accredited 

assessment authority, which authorizes their competence to handle refrigerants 

safely in accordance with an industry recognized assessment specification.

Содержание SKY-3A

Страница 1: ... Connect or clean the exhaust air hose Reset the temperature Clean the air inlet Room temperature is higher than the setting temperature Electric heating mode Room temperature is lower than the setting temperature Cooling mode The doors or windows are not closed There are heat sources inside the room Exhaust air hose is not connected or blocked Temperature setting is too high Air inlet is blocked ...

Страница 2: ...of the refrigerant circuit If the appliance is installed operated or stored in a nonventilated area the room must be designed to prevent to the accumulation of refrigerant leaks resulting in a risk of fire or explosion due to ignition of the refrigerant caused by electric heaters stoves or other sources of ignition VERY IMPORTANT Please do not install or use your mobile air conditioner before you ...

Страница 3: ...ply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard 12 This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe ...

Страница 4: ...l be avoided The area around the workspace shall be sectioned off Ensure that the conditions within the area have been made safe by control of flammable material 1 4 Checking for presence of refrigerant The area shall be checked with an appropriate refrigerant detector prior to and during work to ensure the technician is aware of potentially flammable atmospheres Ensure that the leak tection equip...

Страница 5: ...ystem that there is continuity of earth bonding 2 REPAIRS TO SEALED COMPONENTS 2 1 During repairs to sealed components all electrical supplies shall be disconnected from the equipment being worked upon prior to any removal of 6 sealed covers etc If it is absolutely necessary to have an electrical supply to equipment during servicing then a permanently operating form of leak detection shall be loca...

Страница 6: ...rigerant charge shall be recovered into the correct recovery cylinders The system shall be flushed with OFN to render the unit safe This process may need to be repeated several times Compressed air or oxygen 8 shall not be used for this task Flushing shall be achieved by breaking the vacuum in the system with OFN and continuing to fill until the working pressure is achieved then venting to atmosph...

Страница 7: ...charge are available All cylinders to be used are designated for the recovered refrigerant and labelled for that refrigerant i e special cylinders for the recovery of refrigerant Cylinders shall be complete with pressure relief valve and associated shut off valves in good working order Empty recovery cylinders are evacuated and if possible cooled before recovery occurs The recovery equipment shall...

Страница 8: ... safety equipment before putting into service b Maintenance Portable equipment shall be repaired outside or in a workshop specially 12 equipped for servicing units with flammable refrigerants Ensure sufficient ventilation at the repair place Be aware that malfunction of the equipment may be caused by refrigerant loss and a refrigerant leak is possible Discharge capacitors in a way that won t cause...

Страница 9: ... cause any spark Remove the refrigerant If the recovery is not required by national regulations drain the refrigerant to the outside Take care that the drained refrigerant will not cause any danger In doubt one person should guard the outlet Take special care that drained refrigerant will not float back into the building Evacuate the refrigerant circuit Purge the refrigerant circuit with nitrogen ...

Страница 10: ...humidification and sleep mode the wind speed cannot be adjusted The wind speed will be locked in low wind SLEEP 1 When in cooling mode when press the sleep button to enter sleep mode an hour later the set temperature automatically increase 1 C 2 hours later the set temperature automatically add 2 C 2 When the heating mode when press the sleep button to enter sleep mode an hour later the set temper...

Страница 11: ...F Press on off to start up and then press on off to shut down WIND Press the swing wind button to start the swing wind function Press the swing button again and the left and right swing function will be cancelled 19 TEMP Under cooling and heating function set in the range of 16 31 C temperature Every click on the temperature set temperature reduced by 1 C TEMP Under cooling and heating function se...

Страница 12: ...unctionality Temperature display conversion Press both the temperature and keys and the display will switch between Fahrenheit and Celsius 21 Operation Introduction Before starting operations in this section 1 Find a place where there is power supply nearby 2 Install the exhaust ducts as shown in the figure below and adjust the positions of the mounting plates and windows 3 Insert the power cord i...

Страница 13: ...ctric safety requirements When using functions on cooling and dehumidifying keep an interval of at least 3 minutes between each POWER Power supply meets the requirements The socket is for AC use Do not share one socket with other appliances Power supply is AC220V 50Hz 2 Drainage mode 1 Condensate automatic evaporation drainage The machine can automatically evaporate condensed water and discharge i...

Страница 14: ... 8 Fig 9 25 Maintenance Explanations Declaration 1 Before cleaning be sure to disconnect the unit from any electric supply outlet 2 Do not use gasoline or other chemicals to clean the unit 3 Do not wash the unit directly 4 If the conditioner is damaged please contact the dealer or repair shop Fig 10 1 Air Filter If the air filter becomes clogged with dust dirt the air filter should be cleaned once...

Отзывы: