background image

 

 

 

 

Page 6 of 12 

Drawing   : - TPC508 
Issue 

: - 1 

Date 

: - 29/01/20 

 

 

ROUTINE SERVICE

 

 
 
 
 
 
 
 
 
 
To  ensure  continued  full  efficiency  of  the  dehumidifier,  maintenance 
procedures should be performed as follows: 
 
Removal of the cover is achieved by means of four screws at the sides of the 
unit at base level. With the cover removed all maintenance can be carried out. 

 

 

 

1. 

Clean the surface of the evaporator and condenser coils by blowing 
the  dirt  out  from  behind  the  fins  with  compressed  air.    Hold  the 
nozzle  of  the  air  hose  away  from  the  coil  (approx  6”/150  mm)  to 
avoid damaging the fins.  Alternatively, vacuum clean the coils. 

 
 
 
 
 
 

 

2. 

Check that the fan is firmly secured to the motor shaft and that the 
fan rotates freely. 

 

 

3. 

To  check  the  refrigerant  charge,  run  the  unit  for  15  minutes  and 
briefly remove the cover.  The evaporator coil should be evenly frost 
coated  across  its  surface.    At  temperatures  above  20

°

C,  the  coil 

may  be  covered  with  droplets  of  water  rather  than  frost.    Partial 
frosting  accompanied  by  frosting  of  the  thin  capillary  tubes, 
indicates loss of refrigerant gas or low charge.  

 
 

4. 

Check all wiring connections. 

 
 
 

I

F ANY OF THE PRECEDING PROBLEMS OCCUR

,

 CONTACT THE 

E

BAC 

S

ERVICE 

C

ENTER PRIOR TO CONTINUED OPERATION OF THE UNIT TO 

PREVENT PERMANENT DAMAGE

WARNING: 

ENSURE THAT THE POWER CORD TO THE MACHINE HAS 

BEEN DISCONNECTED BEFORE CARRYING OUT ROUTINE 

SERVICE. THE SERVICING AND REPAIR OF THIS UNIT 

SHOULD ONLY BE CARRIED OUT BY A SUITABLY QUALIFIED 

PERSON. 

WARNING:

 

DO NOT STEAM CLEAN REFRIGERATION COILS 

Содержание CD35S

Страница 1: ...Page 1 of 12 Drawing TPC508 Issue 1 Date 29 01 20 CD35S INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL www eipl co uk...

Страница 2: ...Page 2 of 12 Drawing TPC508 Issue 1 Date 29 01 20 CD35S PACKAGE CONTENTS Item Description Quantity 10186SG US Dehumidifier 1 TPC508 Manual 1...

Страница 3: ...ermanent drain The cooled air then passes through the hot condenser coil where it is reheated using the same energy removed during the cooling phase plus the additional heat generated by the compresso...

Страница 4: ...sed in products manufactured by Ebac Industrial Products Ltd is as follows R134a 1300 R407c 1610 For type and weight of refrigerant contained in this unit please refer to the product data label MODEL...

Страница 5: ...ater container disconnect the power supply and allow the dryer to stand for five minutes Remove the container from the rear of the unit and when emptied replace taking care to ensure that the float me...

Страница 6: ...tor shaft and that the fan rotates freely 3 To check the refrigerant charge run the unit for 15 minutes and briefly remove the cover The evaporator coil should be evenly frost coated across its surfac...

Страница 7: ...he refrigerant compressor The charging stub should be crimped and rebrazed after servicing NEVER allow permanent service valves to be fitted to any part of the circuit Service valves may leak causing...

Страница 8: ...the above 2 Contact the Factory Service Center 3 Contact the Factory Service Center 4 Contact the Factory Service Center Little or no defrost when required 1 Faulty timer 2 Faulty by pass valve 1 Cont...

Страница 9: ...UMIDEX DRAIN TRAY 2139528 REFRIGERATION COIL SET 3014253 CAPILLIARY TUBE 3020811 BY PASS VALVE 3020937 FILTER DRYER 3033033 MICROSWITCH 3035145 HUMIDISTAT 3035346 PANEL MOUNTED TERMINAL BLOCK 3036636...

Страница 10: ...WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THE FOREGOING DESCRIBED MERCHANDISE For Your Records Model ____________________ S N ______________________ Date Received ______________ SAVE THIS SECTION F...

Страница 11: ...oto Protocol The refrigeration system is hermetically sealed The Global Warming Potential GWP of refrigerants used in products manufactured by Ebac Industrial Products Ltd is as follows R134a 1300 R40...

Страница 12: ...ww eipl co uk sales eipl co uk American Sales Office Ebac Industrial Products Inc 700 Thimble Shoals Blvd Suite 109 Newport News Virginia 23606 2575 USA Tel 01 757 873 6800 Fax 01 757 873 3632 www eba...

Отзывы: