background image

 

 

 

 

Page 6 of 12 

Drawing   : - TPC499 
Issue 

: - 1 

Date 

: - 29/01/20 

 

ROUTINE SERVICE 

 
 
 
 
 
 
 

To  ensure  continued  full  efficiency  of  the  dehumidifier,  maintenance 
procedures should be performed as follows: 
 

 

 

 

1. 

Clean the surface of the evaporator and condenser coils by blowing 
the  dirt  out  from  behind  the  fins  with  compressed  air.    Hold  the 
nozzle  of  the  air  hose  away  from  the  coil  (approx  6”)  to  avoid 
damaging the fins.  Alternatively, vacuum clean the coils. 

 
 
 
 
 
 

 

2. 

Check that the fan is firmly secured to the motor shaft and that the 
fan rotates freely.  

The fan motor is sealed for life and therefore 

does not need oiling.

 

 

 

3. 

To  check  the  refrigerant  charge,  run  the  unit  for  15  minutes  and 
briefly remove the cover.  The evaporator coil should be evenly frost 
coated  across  its  surface.    At  temperatures  above  25

°

C,  the  coil 

may  be  covered  with  droplets  of  water  rather  than  frost.    Partial 
frosting  accompanied  by  frosting  of  the  thin  capillary  tubes, 
indicates loss of refrigerant gas or low charge.  

 
 

4. 

Check all wiring connections. 

 

5.  To check the operation of the defrost system, switch the machine on 

and leave it running for approximately 42 minutes.  The machine will 
then  enter  “Hot  Gas”  defrost  mode  for  approximately  4  minutes 
before  returning  to  normal  operation.    If  the  unit  will  not  defrost,  the 
printed circuit timer board may be defective or the by-pass valve may 
be inoperable. 

 

I

F ANY OF THE PRECEDING PROBLEMS OCCUR

,

 CONTACT THE 

E

BAC 

S

ERVICE 

C

ENTER PRIOR TO CONTINUED OPERATION OF THE UNIT TO 

PREVENT PERMANENT DAMAGE

.

  

 

WARNING: 

ENSURE THAT THE POWER CORD TO THE MACHINE HAS 

BEEN DISCONNECTED BEFORE CARRYING OUT ROUTINE 

SERVICE. THE SERVICING AND REPAIR OF THIS UNIT 

SHOULD ONLY BE CARRIED OUT BY A SUITABLY QUALIFIED 

PERSON. 

WARNING:

 

DO NOT STEAM CLEAN REFRIGERATION COILS 

Содержание CD30S

Страница 1: ...Page 1 of 12 Drawing TPC499 Issue 1 Date 29 01 20 CD30S INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL www eipl co uk...

Страница 2: ...Page 2 of 12 Drawing TPC499 Issue 1 Date 29 01 20 CD30S PACKAGE CONTENTS Item Description Quantity 1142000 Dehumidifier 1 3014338 PVC tube 12mm I D 3 M 3086101 Jubilee clip 1 TPC449 Manual 1...

Страница 3: ...point Moisture forms on the evaporator coil and is collected in the condensate tray which is equipped with a permanent drain The cooled air then passes through the hot condenser coil where it is rehe...

Страница 4: ...he Global Warming Potential GWP of refrigerants used in products manufactured by Ebac Industrial Products Ltd is as follows R134a 1300 R407c 1610 For type and weight of refrigerant contained in this u...

Страница 5: ...d Leave the machine running for 15 minutes e Observe the evaporator coils to confirm frost formation i If the air temperature is below 70 F an even coating of frost should cover the entire evaporator...

Страница 6: ...e 25 C the coil may be covered with droplets of water rather than frost Partial frosting accompanied by frosting of the thin capillary tubes indicates loss of refrigerant gas or low charge 4 Check all...

Страница 7: ...he refrigerant compressor The charging stub should be crimped and rebrazed after servicing NEVER allow permanent service valves to be fitted to any part of the circuit Service valves may leak causing...

Страница 8: ...oss of refrigerant gas 4 Blocked filter dryer 1 Check all of the above 2 Contact the Factory Service Center 3 Contact the Factory Service Center 4 Contact the Factory Service Center Little or no defro...

Страница 9: ...R Compressor 1 3944958 Refrigeration Coil Set 1 2139528 Fan Motor 1 3035773 Fan Blade 1 3040129 Timer Board 1 1619519 Humidistat 1 3035145 Humidistat Knob 1 3030421 Solenoid Coil 1 3020421 Defrost By...

Страница 10: ...oto Protocol The refrigeration system is hermetically sealed The Global Warming Potential GWP of refrigerants used in products manufactured by Ebac Industrial Products Ltd is as follows R134a 1300 R40...

Страница 11: ...Page 11 of 12 Drawing TPC499 Issue 1 Date 29 01 20...

Страница 12: ...ww eipl co uk sales eipl co uk American Sales Office Ebac Industrial Products Inc 700 Thimble Shoals Blvd Suite 109 Newport News Virginia 23606 2575 USA Tel 01 757 873 6800 Fax 01 757 873 3632 www eba...

Отзывы: