GB
- 18 -
6.3 Setting the reference point (Fig. 3 - 4)
Measurements can be performed from two dif-
ferent reference points on the equipment. To do
so, press button B and keep it pressed until the
reference point changes. This is how you select
the reference point you require.
•
Front edge reference point (see Fig. 4)
•
Rear edge reference point (see Fig. 4)
6.4 Using the measurement functions
Note:
The laser beam switches o
ff
automatically after
completion of each measurement. Press the ON/
Measuring button.
6.4.1 Function: “Measure single distance”
“No symbol” (Fig. 5)
Procedure:
•
Press button A once and keep it pressed for a
short time: Switch on the equipment
•
Press button B for longer if necessary: Select
the reference point on the equipment
•
Press button A once: Switch on the laser
•
Align the laser
•
Press button A once: Measure
→
The result is displayed at the bottom in m
6.4.2 Function: “Measure areas”
“Symbol
” (Fig. 6)
Procedure:
•
Press button A once and keep it pressed for a
short time: Switch on the equipment
•
Press button B once: Select function
•
Press button B for longer if necessary: Select
the reference point on the equipment
•
Press button A once: Switch on the laser
•
Align the laser
•
Press button A once: area length
•
Press button A once: Switch on the laser
•
Align the laser
•
Press button A once: Measure the area width
→
The result is displayed at the bottom in m²
6.4.3 Function: “Measure volumes”
“Symbol
“ (Fig. 7)
Procedure:
•
Press button A once and keep it pressed for a
short time: Switch on the equipment
•
Press button B twice: Select function
•
Press button B for longer if necessary: Select
the reference point on the equipment
•
Press button A once: Switch on the laser
•
Align the laser
•
Press button A once: Measure the room
length
•
Press button A once: Switch on the laser
•
Align the laser
•
Press button A once: Measure the room width
•
Press button A once: Switch on the laser
•
Align the laser
•
Press button A once: Measure the room
height
→
The result is displayed at the bottom in m³
6.4.4 Function: “Measure continuous
distance (min)”
“Symbol
” (Fig. 8 / 8a)
Procedure:
•
Press button A once and keep it pressed for a
short time: Switch on the equipment
•
Press button B three times: Select function
•
Press button B for longer if necessary: Select
reference point
•
Press button A once: Switch on the laser
•
Press button A once: Continuous measure-
ment
→
The lowest measurement result so far is
displayed at the top in m
→
The current measurement result is dis-
played at the bottom in real time
Anl_TC_LD_25_SPK9.indb 18
Anl_TC_LD_25_SPK9.indb 18
18.03.2019 13:43:56
18.03.2019 13:43:56
Содержание TC-LD 25
Страница 4: ...4 max 8b Anl_TC_LD_25_SPK9 indb 4 Anl_TC_LD_25_SPK9 indb 4 18 03 2019 13 43 53 18 03 2019 13 43 53...
Страница 83: ...GR 83 Anl_TC_LD_25_SPK9 indb 83 Anl_TC_LD_25_SPK9 indb 83 18 03 2019 13 44 01 18 03 2019 13 44 01...
Страница 92: ...92 Anl_TC_LD_25_SPK9 indb 92 Anl_TC_LD_25_SPK9 indb 92 18 03 2019 13 44 02 18 03 2019 13 44 02...
Страница 93: ...93 Anl_TC_LD_25_SPK9 indb 93 Anl_TC_LD_25_SPK9 indb 93 18 03 2019 13 44 02 18 03 2019 13 44 02...
Страница 94: ...EH 03 2019 02 Anl_TC_LD_25_SPK9 indb 94 Anl_TC_LD_25_SPK9 indb 94 18 03 2019 13 44 02 18 03 2019 13 44 02...