background image

®

Operating Instructions for the 
Indoor and Outdoor Device

Split-system Air Conditioner

SKA

3501 EQ C+H

Art.-Nr.: 23.657.30

I.-Nr. 01014

Important note:

This high-quality product will only offer
optimum service if installed correctly and in
the right place, and is put into operation for
the first time by a suitably competent person.
Avoid malfunctions by seeking competent
advice from an expert with regards to the
location, installation and starting up of the
system.
We shall accept no liability for malfunctions
or inadequate cooling performance resulting
from the improper handling of the product.

All 

230V 

electrical work on the system, namely

electrical connections and putting it into
operation for the first time, is to be performed
by a qualified electrician only.

Should you ever have to dispose of the
system, all work of removal, disassembly and
disposal is to be performed by an electrician
or refrigeration specialist only.

Anleitung SKA 3501 EQ C+H GB  13.12.2004  8:44 Uhr  Seite 1

Содержание SKA 3501 EQ C+H

Страница 1: ...ith regards to the location installation and starting up of the system We shall accept no liability for malfunctions or inadequate cooling performance resulting from the improper handling of the produ...

Страница 2: ...83 x 54 5 x 25 5 Weight Indoors kg 10 Outdoors kg 34 Note The specified capacities and performances are based on the following conditions Cooling Air temperature at the inlet on the indoor device 27...

Страница 3: ...tally in the cooling function and downwards in the heating function Independent dehumidifying function Computer controlled dehumidifying function without changing the room temperature Disk piston blow...

Страница 4: ...hed periodically otherwise there is a risk of lack of oxygen Never use the device for any other purpose than the intended use Never place food precision instruments plants animals paint etc on the dev...

Страница 5: ...nt 5 Drainage water outlet Outdoor device 1 3 7 5 4 6 2 1 Front panel 2 Air outlet vent 3 Air filter 4 Left right slats 5 Controller 6 Emergency switch 7 Remote control 8 Color display 9 Top bottom sl...

Страница 6: ...g is completed after approx 8 seconds 5 Time setting The Start time sleep and the h hours indicator light up The digits show the remaining time to run For setting the sleep function the digital indica...

Страница 7: ...velocity 6 Sleep selection key 7 Timer on key 8 Hours selection switch minute setting time setting 9 Clock setting 10 Temperature adjustment key 11 Key for setting the air flow angle 12 Full blast key...

Страница 8: ...ll not be possible Press the clock setting key with a pointed object Press the hours minutes with the time setting key and set the right time Press the hours key and set the hours Press the minutes ke...

Страница 9: ...trol becomes difficult to read replace the batteries immediately It is important that the and terminals on the batteries are correctly positioned in the remote control Both batteries should always be...

Страница 10: ...ease the temperature with the key too cool Each press of the key will increase the temperature by 1 C To start Press the ON OFF KEY If automatic function is indicated the air conditioner switches to a...

Страница 11: ...same function setting that it had before it stopped Once the corresponding function has become set it will no longer be affected by the room temperature even if it changes If you do not wish to use t...

Страница 12: ...e outdoor temperature and the nature of the particular building Note If during operation the room temperature is more than 2 C above cool or less than 2 C below heat the set point temperature the set...

Страница 13: ...et to the automatic function this function cannot be changed Selecting the function cool dehumidify Monitoring during operation 1 In order to increase the cooling effect close the windows and lower th...

Страница 14: ...y changes the air velocity as follows Low moderate high automatic Select a high setting if you wish to cool the entire room Select the sleep function when you want to sleep and wish to reduce the nois...

Страница 15: ...ection and velocity Adjusting the air velocity and direction of flow Automatic air flow Press the key change the air flow to automatic and the optimum slat position will be selected for efficient effe...

Страница 16: ...ction is for a quiet room while sleeping Important Start this function just before you go to sleep If you start it during the day it is possible that the ambient temperature will become too hot becaus...

Страница 17: ...oled Proceed as follows Press the key Press the key during full blast to stop the operation Once the full blast function has been started the cool air will reach every corner of the room The cancel Pr...

Страница 18: ...setting 1 Press the key during operation to set the timer to OFF Each press of the key changes the sequence Timer OFF switch off 2 Press the hours and minutes key to set the Timer OFF to the right ti...

Страница 19: ...he highest possible temperature level while the fans are running 2 Switch off the device and pull the power plug Important Always pull out the power plug if the device is not going to be used for some...

Страница 20: ...ly sealed There may not be enough coolant If so please contact your service company The remote control does not work Important It only works within a range of 6 m from the indoor device 1 Are the batt...

Страница 21: ...t The temperature increases when water evaporates on the heat exchanger in the indoor device This is not a fault The coolant in the air conditioner may have expanded This is not a fault The ventilatio...

Страница 22: ...Selecting the place to install the outdoor device The device must not be exposed to strong gusts of wind Make sure that the device is well ventilated and kept free of dust Avoid direct exposure to ra...

Страница 23: ...of heat high humidity or inflammable gas 5 Select a location which is firm enough for installation so that the device is not subjected to vibrations 6 Check that the device has been installed correct...

Страница 24: ...gh the wall Drill the hole through the wall for the lines hoses using a 65mm drill bit drilling from the inside to the outside at an angle downwards of approx 5 Then insert the wall hole tube in the h...

Страница 25: ...coolant tubes 5 1 Important notes Please make sure that coolant is never allowed to enter the environment Improper handling of coolant may be harmful to health Always wear work gloves and goggles when...

Страница 26: ...guard back on the outdoor device Fasten the complete package of lines with the protective tape wrapped around them to the outside wall using the supplied plastic clamps 7 Remote control holder Before...

Страница 27: ...ulting from improper installation by the user including installation by any parties other than parties authorized by us and any modifications following initial installation 4 We shall not accept liabi...

Страница 28: ...ere ince a a daki uygunluk a kla mas n sunar I dichiara la seguente conformit secondo la direttiva UE e le norme per l articolo attesterer f lgende overensstemmelse i henhold til EU direktiv og standa...

Страница 29: ...hrte Serviceadresse ISC GmbH International Service Center Eschenstra e 6 D 94405 Landau Isar Germany Info Tel 0180 5 120 509 Telefax 0180 5 835 830 Service und Infoserver http www isc gmbh info Techni...

Страница 30: ...30 Anleitung SKA 3501 EQ C H GB 13 12 2004 8 44 Uhr Seite 30...

Страница 31: ...ial waste management legislation This does not apply to the accessories and auxiliary equipment without any electrical components which are included with the used device For EU countries only Never pl...

Страница 32: ...ing or reproduction by any other means in whole or in part of documentation and papers accompanying products is permitted only with the express consent of ISC GmbH Anleitung SKA 3501 EQ C H GB 13 12 2...

Отзывы: