![EINHELL MK 2100 E Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/einhell/mk-2100-e/mk-2100-e_original-operating-instructions_2370221025.webp)
GB
- 25 -
8. Technical data
MK 2100 E
MK 2300 E
MK 2600 E
Mains voltage
220 - 240V ~ 50Hz 220 - 240V ~ 50Hz 220 - 240V ~ 50Hz
Refrigerant
R410A
R410A
R410A
Refrigerant group
L1
L1
L1
Coolant quantity
350g
(0.73 t CO
2
Äq.)
390g
(0.81 t CO
2
Äq.)
370g
(0.77 t CO
2
Äq.)
Rated cooling capacity (P
rated
) in kW
2.1
2.3
2.6
Recommended max. room size in m
3
50
65
80
Rated power consumption (P
rated
) in kW 0.805
0.88
0.996
Rated cooling capacity (EERd)
2.61
2.61
2.61
Energy efficiency class
A
A
A
Power consumption (P
TO
) in W
123
102.3
123
Power consumption (P
SB
) in W
0.95
0.95
0.95
Area of application room temperature
18 – 32 °C
18 – 32 °C
18 – 32 °C
Max. pressure (MPA)
4.2
4.2
4.2
Max. dehumidifier capacity l/h
(30°C / 80% RH)
0.8
1.0
1.0
Fan speed levels
2 + Automatic
2 + Automatic
2 + Automatic
Timer (in h)
1-12
1-12
1-12
Max. air throughput (m
3
/h)
370
355
375
Rated current consumption (A)
3.5
4.1
4.5
Compressor type
Rotary piston
Rotary piston
Rotary piston
Compressor starting current RLA max.
(A)
18
19
20
Sound power level db(A)
65
65
65
Greenhouse warming potential
(GWP, kg CO
2
eq.)
2088
2088
2088
Exhaust air hose (
Ǿ
x L in mm)
127x1500
127x1500
127x1500
Housing dimensions WxDxH in cm
30.5 x 38.3 x 75.2 30.5 x 38.3 x 75.2 30.5 x 38.3 x 75.2
Anleitung_MK_2100_E_SPK7.indb 25
Anleitung_MK_2100_E_SPK7.indb 25
25.09.2018 10:12:41
25.09.2018 10:12:41