EINHELL GE-WW 5537 E Скачать руководство пользователя страница 5

3. Items supplied

Open the packaging and take out the equipment
with care.

Remove the packaging material and any
packaging and/or transportation braces (if
available).

Check to see if all items are supplied.

Inspect the equipment and accessories for
transport damage.

If possible, please keep the packaging until the
end of the guarantee period.

IMPORTANT
The equipment and packaging material are not
toys. Do not let children play with plastic bags,
foils or small parts. There is a danger of
swallowing or suffocating!

Original operating instructions

4. Proper use

Applications

Irrigation and watering of green areas, vegetable
beds and gardens.

Operation of lawn sprinklers.

For drawing water from ponds, streams, rainwater
butts, rainwater cisterns and springs

For supplying service water

Transport media:

For the pumping of clear water (fresh water),
rainwater or light suds/service water.

The maximum temperature of the fluid must not
35°C if the equipment is operated
permanently.

Do not use the equipment to pump inflammable,
gassing or explosive fluids.

The pumping of aggressive liquids (acids, alkalis,
silo seepage etc.) as well as liquids with abrasive
substances (sand) must likewise be avoided.

This equipment is not designed to convey
drinking water.

The equipment is to be used only for its prescribed
purpose. Any other use is deemed to be a case of
misuse. The user / operator and not the manufacturer
will be liable for any damage or injuries of any kind
caused as a result of this.

Please note that our equipment has not been
designed for use in commercial, trade or industrial
applications. Our warranty will be voided if the

machine is used in commercial, trade or industrial
businesses or for equivalent purposes.

5. Technical data

Mains connection

230V ~ 50 Hz

Power rating

590 W

Pumping rate without non-return valve:

3750 l/h

Pumping rate with non-return valve:

3450 l/h

Max. delivery head 

38 m

Max. delivery pressure

0.38 MPa (3.8 bar)

Max. suction height

8 m

Pressure and suction connector

33.3 mm (R1IG)

Max. water temperature 

35 °C

Tank capacity

20 l

Cut-in pressure approx.

0.15 MPa (1.5 bar)

Cut-out pressure approx.

0.30 MPa (3.0 bar)

6. Before putting the equipment into

operation

6.1 Connecting the intake line

The intake hose or pipe should have a minimum
diameter of 25 mm (1”); a diameter of 32 mm
(11/4”) is recommended for suction heights
exceeding 5 m.

Connect the intake valve (foot valve) with intake
cage to the intake line.

Position the intake line so that it rises from the
water withdrawal point to the equipment. Avoid
positioning the suction pipe higher than the pump,
as this would delay the escape of air bubbles
from the suction pipe and impede the priming
process.

Install the intake and discharge lines in such a
way that they do not exert any mechanical
pressure on the equipment.

The intake valve should be low enough in the
water to ensure that if the water level falls, the
equipment will not run dry.

A leaking intake line will draw in air and therefore
not draw in any water.

6.2 Connecting the discharge line

Screw the adapter (12) onto the pressure
connection (1), then you can fasten the supplied
garden hose (13).

The discharge line (min. 19 mm (3/4”)) must be
connected to the 33.3 mm (R1IG) female thread

10

GB

Anleitung_GE_WW_5537_E_SPK7__  11.11.13  08:04  Seite 10

Содержание GE-WW 5537 E

Страница 1: ...nal operating instructions Home Waterworks p Mode d emploi d origine Syst me domestique de pomage d eau C Istruzioni per l uso originali Centralina idrica 7 GE WW 5537 E Art Nr 41 731 76 I Nr 11023 An...

Страница 2: ...structions and safety information before using for the first time F Avant la mise en service lisez le mode d emploi et les consignes de s curit et respectez les I Prima della messa in esercizio legget...

Страница 3: ...1 5 6 2 1 7 3 4 3 2 10 3 7 9 10 7 9 8 11 14 12 13 Anleitung_GE_WW_5537_E_SPK7__ 11 11 13 08 04 Seite 3...

Страница 4: ...rnal influences the cable may not be repaired The cable must be replaced by a new one This work may only be carried out by a trained electrician The voltage of 230 V alternating voltage specified on t...

Страница 5: ...d for use in commercial trade or industrial applications Our warranty will be voided if the machine is used in commercial trade or industrial businesses or for equivalent purposes 5 Technical data Mai...

Страница 6: ...nce and ordering of spare parts The equipment is almost completely maintenance free In order to ensure a long service life however we recommend that you regularly check and care for the product Import...

Страница 7: ...equired For our latest prices and information please go to www isc gmbh info 10 Storage Store the equipment and accessories out of children s reach in a dark and dry place at above freezing temperatur...

Страница 8: ...e line is close Check suction height Inadequate delivery rate Suction height too high Coarse filter dirty Water level falling rapidly Pump performance diminishedby contaminants part Check suction heig...

Страница 9: ...kaidro du atbilst bu ES direkt vai un standartiem G apib dina atitikim EU reikalavimams ir prek s normoms Q declar urm toarea conformitate conform directivei UE i normelor pentru articolul z B potvr u...

Страница 10: ...As an alternative to returning the electrical device the owner is obliged to cooperate in ensuring that the device is properly recycled if ownership is relinquished This can also be done by handing o...

Страница 11: ...s is permitted only with the express consent of ISC GmbH F La r impression ou une autre reproduction de la documentation et des documents d accompagnement des produits m me incompl te n est autoris e...

Страница 12: ...Technische nderungen vorbehalten G Technical changes subject to change F Sous r serve de modifications I Con riserva di apportare modifiche tecniche Anleitung_GE_WW_5537_E_SPK7__ 11 11 13 08 04 Seite...

Страница 13: ...30 Anleitung_GE_WW_5537_E_SPK7__ 11 11 13 08 04 Seite 30...

Страница 14: ...31 Anleitung_GE_WW_5537_E_SPK7__ 11 11 13 08 04 Seite 31...

Страница 15: ...r incorrect use for example overloading the device or the use or unapproved tools or accessories ingress of foreign bodies into the device such as sand stones or dust transport damage the use of force...

Отзывы: