Pumped media:
•
For the pumping of clear water (freshwater),
rainwater or mild suds/service water.
•
The maximum temperature of the pumped
medium must not 35 °C when the
equipment is operated continuously.
•
Do not use the equipment to pump inflamma-
ble, gassing or explosive liquids.
•
The pumping of aggressive liquids (acids,
alkalis, silo seepage etc.) as well as liquids
containing abrasive substances (sand) must
also be avoided.
•
This equipment is not designed to pump drin-
king water.
The equipment is to be used only for its prescri-
bed purpose. Any other use is deemed to be a
case of misuse. The user / operator and not the
manufacturer will be liable for any damage or inju-
ries of any kind caused as a result of this.
Please note that our equipment has not been de-
signed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
4. Technical data
Mains connection ...................220-240 V ~ 50 Hz
Power rating ........................................... 1100 W
Delivery rate ........................................... 4400 l/h
Delivery head max. ..................................... 48 m
Delivery pressure max. .......... 0.48 MPa (4.8 bar)
Intake height max. ......................................... 8 m
Discharge connection
.................... approx. 33.3 mm (R1 female thread)
Intake connection
....................... approx. 42 mm (R1¼ male thread)
Water temperature max. ............................. 35 °C
Measured sound power level L
WA
...... 76.3 dB(A)
Uncertainty K
WA
...................................... 2.01 dB
Guaranteed sound power level L
WA
....... 78 dB(A)
Protection .....................................................IPX4
5. Before starting the equipment
Before you connect the equipment to the power
supply make sure that the data on the rating plate
is the same as the mains data.
5.1 Connecting the intake line
•
Fasten the intake hose (plastic hose of at
least approx. 19 mm (¾“) with spiral reinforce-
ment) to the equipment’s intake connection
of approx. 42 mm (R1¼ male thread) either
directly or via a threaded nipple.
•
Use the connection adapter (8) to reduce the
thread of the intake connection to approx.
33.3 mm (R1 male thread).
•
Position the intake line so that it rises from
the water withdrawal point to the equipment.
Avoid positioning the intake line higher than
the pump as this would delay the escape of
air bubbles from the intake line and impede
the priming process.
•
Install the intake and discharge lines in such
a way that they do not exert any mechanical
pressure on the equipment.
•
The intake valve should be low enough in the
water to ensure that if the water level falls, the
equipment will not run dry.
•
A leaking intake line will draw in air and there-
fore not draw in any water.
•
Prevent the intake of foreign bodies (sand
etc.). If necessary, install a coarse filter for
this purpose.
5.2 Connecting the discharge line
•
The discharge line (at least approx. 19 mm
(¾“)) must be connected to the equipment’s
discharge line connection of approx. 33.3
mm (R1 female thread) either directly or via a
threaded nipple.
•
Of course you can also use a discharge hose
of approx. 13 mm (½“) with the relevant coup-
lings. The delivery rate is reduced when using
the smaller discharge line.
•
During the priming process, the shut-off de-
vices (spray nozzles, valves etc.) present in
the discharge line must be fully open so that
the air in the intake line can escape freely.
•
When the pump is being used in automatic
mode, make sure that the discharge hose
does not become kinked. If the hose is con-
nected directly to the delivery side, we recom-
mend using an angle piece of approx. 33.3
mm (R1 male thread).
Anl_GE_AW_1144_SMART_SPK13.indb 19
Anl_GE_AW_1144_SMART_SPK13.indb 19
10.01.2022 09:16:30
10.01.2022 09:16:30