11. Troubleshooting guide
Faults
Cause
Remedy
Motor fails to start
up
- No mains voltage
- Pump rotor blocked -thermostat
switched o
ff
- Check voltage
- Dismantle and clean pump
No intake
- Intake valve not in water
- Pump chamber without water con-
nection
- Air in intake line air-tight
- Intake valve leaks
- Strainer (intake valve) blocked
- Max. suction height exceeded
- Immerse intake valve in water
- Fill water into intake
- Make sure intake line is close
- Clean intake valve
- Clean strainer
- Check suction height
Inadequate delivery
rate
- Suction height too high
-
Strainer dirty
- Water level falling rapidly
- Pump performance diminishedby
contaminants part
- Check suction height
-
Clean strainer
- Place the suction hose at a deeper
level
- Clean pump and replace wearing
Thermostat swit-
ches pump o
ff
- Motor overloaded - friction caused
by foreign substances too high
- Dismantle and clean pump. Prevent
intake of foreign substances (
fi
lter)
Anl_GC_AW_9036_SPK7.indb 18
Anl_GC_AW_9036_SPK7.indb 18
23.06.14 16:38
23.06.14 16:38
Содержание GC-AW 9036
Страница 112: ...GR 112 8 Anl_GC_AW_9036_SPK7 indb 112 Anl_GC_AW_9036_SPK7 indb 112 23 06 14 16 38 23 06 14 16 38...
Страница 117: ...GR 117 11 Anl_GC_AW_9036_SPK7 indb 117 Anl_GC_AW_9036_SPK7 indb 117 23 06 14 16 38 23 06 14 16 38...
Страница 118: ...GR 118 2012 19 iSC GmbH M Anl_GC_AW_9036_SPK7 indb 118 Anl_GC_AW_9036_SPK7 indb 118 23 06 14 16 38 23 06 14 16 38...
Страница 119: ...GR 119 www isc gmbh info Anl_GC_AW_9036_SPK7 indb 119 Anl_GC_AW_9036_SPK7 indb 119 23 06 14 16 38 23 06 14 16 38...
Страница 131: ...131 Anl_GC_AW_9036_SPK7 indb 131 Anl_GC_AW_9036_SPK7 indb 131 23 06 14 16 38 23 06 14 16 38...
Страница 132: ...EH 06 2014 01 Anl_GC_AW_9036_SPK7 indb 132 Anl_GC_AW_9036_SPK7 indb 132 23 06 14 16 38 23 06 14 16 38...