EINHELL 42.585.71 Скачать руководство пользователя страница 2

2

Change the gear only when the drill is at a standstill. If you fail to observe this point, the
gearing may be damaged.

Anleitung RT-MX_1600E_SPK1:_  08.03.2010  8:50 Uhr  Seite 2

Содержание 42.585.71

Страница 1: ...Art Nr 42 585 71 I Nr 11011 RT MX 1600 E Original operating instructions Paint and Mortar Mixer Anleitung RT MX_1600E_SPK1 _ 08 03 2010 8 50 Uhr Seite 1 ...

Страница 2: ...2 Change the gear only when the drill is at a standstill If you fail to observe this point the gearing may be damaged Anleitung RT MX_1600E_SPK1 _ 08 03 2010 8 50 Uhr Seite 2 ...

Страница 3: ...3 1 2 5 3 2 1 4 5 6 a b 6b 6a Anleitung RT MX_1600E_SPK1 _ 08 03 2010 8 50 Uhr Seite 3 ...

Страница 4: ...4 3 4 2 4 2 1 1 Anleitung RT MX_1600E_SPK1 _ 08 03 2010 8 50 Uhr Seite 4 ...

Страница 5: ... 2 Layout 3 Proper use 4 Technical data 5 Before starting the equipment 6 Operation 7 Replacing the power cable 8 Cleaning maintenance and ordering of spare parts 9 Disposal and recycling Anleitung RT MX_1600E_SPK1 _ 08 03 2010 8 50 Uhr Seite 10 ...

Страница 6: ...hing mask Dust which is injurious to health can be generated when working on wood and other materials Never use the device to work on any materials containing asbestos Wear safety goggles Sparks generated during working or splinters chips and dust emitted by the device can cause loss of sight Anleitung RT MX_1600E_SPK1 _ 08 03 2010 8 50 Uhr Seite 11 ...

Страница 7: ...ase Never reach into the mixing vessel with your hands or any other object during the mixing process When working with the mixer we recommend that you wear work gloves goggles and ear protectors Wearing close fitting clothes is mandatory Always allow for reaction torque Take the reaction torque into account During operation always hold the equipment firmly in both hands 2 Layout Fig 1 2 1 On Off s...

Страница 8: ...s may arise in connection with the equipment s construction and layout 1 Lung damage if no suitable protective dust mask is used 2 Damage to hearing if no suitable ear protection is used 3 Health damage caused by hand arm vibrations if the equipment is used over a prolonged period or is not properly guided and maintained 5 Before starting the equipment Before you connect the equipment to the mains...

Страница 9: ...hes In case of excessive sparking have the carbon brushes checked only by a qualified electrician Important The carbon brushes should not be rep laced by anyone but a qualified electrician 8 3 Maintenance There are no parts inside the equipment which require additional maintenance 8 4 Ordering replacement parts Please quote the following data when ordering replacement parts Type of machine Article...

Страница 10: ...nd stones or dust effects of force or external influences e g damage caused by the device being dropped and normal wear resulting from proper operation of the device The guarantee is rendered null and void if any attempt is made to tamper with the device 3 The guarantee is valid for a period of 2 years starting from the purchase date of the device Guarantee claims should be submitted before the en...

Страница 11: ...EH 09 2011 01 ...