27
GB
15. Troubleshooting
Fault
Possible causes
Remedies
The motor fails to start
a) The capacitor is defective
a) The mower housing is
clogged Have repaired by
the Customer Service
Center
b) There is no electricity at the plug
b) Check the cable and the
fuse
c) The cable is defective
c) Check the cable
d) The combined switch/plug is
d) Have repaired by the
defective
Customer Service Center
e) The connectors have become
e) Have repaired by the
separated from the motor
Customer Service Center
or the capacitor
f) The mower is standing in high
f) Start in low grass or on an
grass
area that has already
been mowed; change the
cutting height if necessary
g) The mower housing is clogged
g) Clean the housing so that
the blade moves freely
The motor performance drops
a) The grass is too high or too damp
a) Correct the cutting height
b) The mower housing is clogged
b) Clean the housing
c) The blade is severely worn
c) Replace the blade
Cutting is irregular
a) The blade is worn
a) Replace or resharpen the
blade
b) Wrong cutting height
b) Correct the cutting height
Important!
For protection, the motor is equipped with a thermal switch which cuts out when the motor is overloaded and
switches on again automatically after a short cooling period.
Anl EM 1200_SPK1 16.01.2006 13:32 Uhr Seite 27
Содержание 34.002.70
Страница 3: ...3 1 햲 햳 햴 햵 햶 햷 햸 햺 햹 2 햴 햲 햷 햸 햹 햺 햿 햳 햵 헀 헀 햾 햽 햻 햶 Anl EM 1200_SPK1 16 01 2006 13 32 Uhr Seite 3 ...
Страница 4: ...4 3 4 6 8 5 7 C B B A A Anl EM 1200_SPK1 16 01 2006 13 32 Uhr Seite 4 ...
Страница 5: ...5 9 10 11 12 13 14 A A Anl EM 1200_SPK1 16 01 2006 13 32 Uhr Seite 5 ...
Страница 6: ...6 16 15 17 19 18 20 A B A B 1 2 C A A B 1 2 C Anl EM 1200_SPK1 16 01 2006 13 32 Uhr Seite 6 ...
Страница 7: ...7 21 1 2 3 4 5 6 7 22 Anl EM 1200_SPK1 16 01 2006 13 32 Uhr Seite 7 ...
Страница 114: ...114 Anl EM 1200_SPK1 16 01 2006 13 33 Uhr Seite 114 ...
Страница 116: ...EH 12 2005 Anl EM 1200_SPK1 16 01 2006 13 33 Uhr Seite 116 ...