Eikon RMW921 Скачать руководство пользователя страница 5

 

5

 

USER’S 

WARNINGS AND CE CONFORMITY 

 

Changes or modifications not expressly approved by PROEL S.p.A. could void your authority to operate 
the equipment. 

LICENSING INFORMATION:

 

 

Frequency Range of RMW921: 823 

 832 MHz and  863 

 865 MHz.  

 

A  ministerial  license  may  be  required  to  operate  this  equipment  in  certain  areas.  The  use  of  this 
professional wireless microphone equipment in some countries could be intended for professional use, 
so  the  licensability  depends  on  the  country  it  operates.  Proel  suggests  the  user  to  contact  the 
appropriate telecommunications authority concerning proper licensing. 

 

This equipment may be capable of operating on some frequencies not authorized in your country. Please 
contact your national authority to obtain information on authorized frequencies for wireless microphone 
products in your region. 

 

Licensing  of  professional  wireless  microphone  equipment  is  the  user’s  responsibilit

y,  and  licensability 

depends on the user’s classification and application, and on the selected frequency.

 

 

The product is in compliance with 2014 / 30/ EU  EMC Directive  &  2014 /35 / EU   LVD  Directive. 

 

PROEL  S.p.A  hereby,  declares  that  this  wireless  microphone  system  complies  with  the  essential 
requirements of Radio Equipment  Directive ( RED ) 2014 / 53 / EU. 

 

The full and detailed declaration of conformity can be downloaded from the web site:  

www.Eikon-audio.com

  

 

TABLE OF THE AUTHORIZED FREQUENCIES FOR THE RMW921 WIRELESS MICROPHONE SYSTEM IN EUROPE 
UPDATED WITH REFERENCE TO ERC-REC 70-03E DOCUMENT DATED FEBRUARY 7 2014 

COUNTRY CODE 

WM9M / WM9B TRANSMITTING FREQUENCIES (MHz) 

823.000-832.000  

863.000 - 865.000 

BE CZ DK FI DE IS IE LI LU CH ES SI AL MD 
TR 

Individual license required 

no personal license 

required 

AT EE FR IT LT PL SE GB 

Individual license required and/or 

Limited implementation 

BG CY HR GR HU LV MT NL NO PT RO SK BA 
MK ME RU RS UA 

NOT IMPLEMENTED 

GE 

NOT IMPLEMENTED 

IN ALL COUNTRIES THE USE OF WIRELESS MICROPHONES SYSTEMS IS SUBJECT TO ANY TELEVISION AND 

BROADCAST TRANSMISSION 

CONSULT LOCAL OR NATIONAL RADIO SPECTRUM AUTHORITIES FOR INFORMATION ON POSSIBLE 

RESTRICTIONS OR NECESSARY AUTHORIZATIONS BEFORE USING THIS SHORT RANGE DEVICE. 

 

Содержание RMW921

Страница 1: ...RMW921 Wireless Microphone System USER S MANUAL ITALIANO ENGLISH 96MAN00921 REV 01 19...

Страница 2: ...TY AND PRODUCTS RETURN 3 MAINTENANCE AND DISCLAIMER 4 POWER SUPPLY 4 USER S WARNINGS AND CE CONFORMITY 5 INTRODUCTION 6 DESCRIPTION 6 RMW921 RECEIVER 6 RMW921 MENU OPTIONS 8 WM9M HANDHELD MICROPHONE T...

Страница 3: ...ects and liquids do not go inside the product The product should be connected to a power supply only of the type described on the operating instructions or as marked on the product IN CASE OF FAULT In...

Страница 4: ...tallation non applying safety instructions Proel S p A reserves the right to change these specifications at any time without notice Proel S p A declines any liability for damages to objects or persons...

Страница 5: ...ication and on the selected frequency The product is in compliance with 2014 30 EU EMC Directive 2014 35 EU LVD Directive PROEL S p A hereby declares that this wireless microphone system complies with...

Страница 6: ...DC adaptor use only the adaptor supplied with the system 3 OUTPUT BAL Balanced output with mic level connect it through a XLR cable to a mixer MIC input This output is used preferably for long runs 4...

Страница 7: ...s present the mute can be enabled or disabled only from the transmitter units d AF this meter shows the audio frequency signal send to the outputs If no AF signal is present when the user speaks into...

Страница 8: ...l the receiver is less sensible to disturbances but has a shorter range Name Select Name to set a name for the microphone Press to select then press The display shows the last stored name press to cha...

Страница 9: ...press then pressing choose OFF and press to confirm Tune Select Tune to choose manually a reception frequency Press to select then press The display will shows the last used frequency number flashing...

Страница 10: ...d c This is the battery level explained below the batteries are fully charged and you have 6 8 hours of working operation the batteries are half charged and you have half hour of working operation the...

Страница 11: ...choose between to display the frequency or to display the channel number Each option must be confirmed pressing again the SET button d to lock the bodypack from involuntary changes press SET button a...

Страница 12: ...inside the battery inlet BATTERY REPLACEMENT For the Battery replacement use always 2x 1 5V AA size LITHIUM or ALKALINE type for the best performances You can use also rechargeable batteries but in t...

Страница 13: ...frequency preset RF Frequency Band UHF 823 832 MHz and 863 865 MHz RF Power max 10 mW Modulation method FM F3E RF Max deviation 50 KHz compressor expander system RF Frequency Stability 0 005 10 50 c...

Страница 14: ...14...

Страница 15: ...LAMI 16 GARANZIE E RESI 16 MANUTENZIONE E LIMITAZIONI D USO 17 ALIMENTAZIONE 17 AVVERTENZE PER L UTILIZZO E CONFORMIT CE 18 INTRODUZIONE 19 DESCRIZIONE 19 RICEVITORE RMW921 19 RMW921 OPZIONI DI MENU 2...

Страница 16: ...sicurezza dall acqua dalla pioggia e dai luoghi ad alto grado di umidit Collocare o posizionare il prodotto lontano da fonti di calore quali radiatori griglie di riscaldamento e ogni altro dispositivo...

Страница 17: ...t per danni a terzi causati da mancata manutenzione manomissioni uso improprio o installazione non eseguita secondo le norme di sicurezza Proel S p A si riserva di modificare il prodotto e le sue spec...

Страница 18: ...che Il radio microfonico EIKON conforme alla direttiva 2014 30 EU Direttiva EMC 2014 35 EU Direttiva LVD La Proel S p A dichiara che Il radio microfonico EIKON conforme ai requisiti essenziali ed alle...

Страница 19: ...llici e a non pi di 40m dal trasmettitore Il circuito di ricezione interno true diversity sceglie il miglior segnale da una delle due antenne 2 12VDC IN Connettore per il collegamento dell adattatore...

Страница 20: ...o al mixer Se nessun segnale RF presente automaticamente il ricevitore attiva il mute Quando presente un segnale RF il mute pu essere abilitato o disabilitato solo dal trasmettitore d AF mostra il seg...

Страница 21: ...mpostando un livello maggiore il ricevitore meno sensibile ai disturbi ma ha un raggio d azione pi stretto Name Scegliere Name per impostare il nome del radiomicrofono Premere per scegliere quindi pre...

Страница 22: ...cevitore premere quindi premendo scegliere OFF e premere per confermare Tune Scegliere Tune per impostare manualmente una frequenza di ricezione Premere per scegliere quindi premere Il display mostrer...

Страница 23: ...pare quando il MUTE attivato c Questo il livello della batteria le batterie sono completamente cariche e si hanno 6 8 ore di attivit le batterie sono per met cariche e si ha mezzora di attivit le batt...

Страница 24: ...quenza or per mostrare il numero di canale Ogni opzione deve essere confermata premendo nuovamente il tasto SET d per bloccare il bodypack da involontari cambiamenti premere ancora il tasto SET e usar...

Страница 25: ...ispettare sempre la polarit indicata nel comparto batterie SOSTITUZIONE BATTERIE Per la sostituzione delle batterie usare sempre 2x 1 5V tipo AA al LITHIUM o ALKALINE per ottenere I migliori risultati...

Страница 26: ...enze RF UHF 823 832 MHz and 863 865 MHz Potenza RF max 10 mW Tipo di modulazione RF FM F3E Max deviazione RF 50 KHz con sistema compressore espansore Stabilit frequenza RF 0 005 10 50 c Emissioni Spur...

Страница 27: ...27 FIG 1...

Страница 28: ...28 FIG 2...

Страница 29: ...29 FIG 3...

Страница 30: ...30...

Страница 31: ...31...

Страница 32: ...32 is a brand of PROEL S p A World Headquarters Factory Via alla Ruenia 37 43 64027 Sant Omero Te Italy Tel 39 0861 81241 Fax 39 0861 887862 www eikon audio com...

Отзывы: