Eiki A-3 Movement Sensor manual.                                                             Page 

2

 

To the Installer

 

Thank you for choosing 

Eiki A-3.

  

The A-3 uses passive infra-red technology 
to detect movement in a room. It is 
intended to be used with the Eiki range of 
control systems to automatically shut 
down equipment in the room after a period 
of time when no movement is detected, so 
saving energy and maximising projector 
lamp life.  
Before commencing installation, please 
read these instructions carefully to get the 
best results from your A-3. 

For your safety 

Please ensure that any wiring used to 
connect A-3 to other equipment is kept 
clear of mains wiring and follows 
applicable local wiring codes. Under 

no 

circumstances

 may an A-3 be connected 

directly to power mains wiring. 
Make sure that the power supply you are 
using meets your local safety regulations 
and that its voltage does not exceed 15 
volts DC. Unregulated power supplies can 
output voltages that are well above what is 
shown on their label. 
The A-3 is intended for 

indoor

 use only. 

Mounting 

Choose a location on a wall that is 
preferably 3 to 4 metres from the floor, not 
adjacent to heating or air conditioning 
outlets or opposite windows and where 
people moving in the room can be “seen” 
by the A-3. 
Remove the cover by placing a small flat-
bladed screwdriver in the bottom of the 
case and gently prise the cover off. 

DO NOT TOUCH THE PYRO SENSOR 
INSIDE WITH YOUR FINGERS! 

You may remove the circuit board to 
facilitate mounting the base to the wall. To 
do this, lift the white plastic tab at the 
lower side and push the board up until it 
clears the keyhole slot at the top. At this 
point the board may be lifted out of the 
base. 
When replacing the board, to achieve 
optimum coverage, adjust the position of 
the board in the base to match the height 
of the A-3 above the floor. Moving the 
board higher will lower the beam angle. 
Please refer to the Mounting Height scale 
on the right-hand side of the board. 
After wiring, refit the cover with its lens. 
The cover must be in place in order to test 
the A-3. 

 

 
 
 
 

NOTE: 

This symbol and recycle system apply to EU

countries only and do not apply to countries in other
areas of the world. 

 
 
 
 
 
 
 
 
 

 
 
 
Please dispose of this equipment at your local
community waste collection/recycling centre. In the
European Union there are separate collection systems
for used electrical and electronic products. 

Your EIKI product is designed
and manufactured with high
q u a l i t y   m a t e r i a l s   a n d
components which can be
recycled and reused. 
This symbol means that
electrical and electronic
equipment, at their end-of-life,
should be disposed of
separately from your
household waste. 

This product 
conforms to the 
EMC directive 

89/336 CCE 

Keyhole 

slot 

Cable 
access 

knockout

Mounting 
height 

pointer 

Mounting 
hole 

knockout

Pyro 

sensor 

White plastic 

tab 

V:E1.01 

Отзывы: