![Eiki LC-XG110 Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/eiki/lc-xg110/lc-xg110_service-manual_2369878028.webp)
-26-
Electrical Adjustments
1. Receive the 16-step gray scale computer signal with
Computer 1 [Analog RGB]
mode.
2. Enter the service mode.
3. Connect an oscilloscope to test point “
TP531
” (+) and
chassis ground (-).
4. Select group no. “
5
”, Item no. “
11
” and adjust the
black level to be maximum amplitude by changing the
Data value.
5. Connect an oscilloscope to test point “
TP501
” (+) and
chassis ground (-).
6. Select Item no. “
12
” and adjust the black level to be
maximum amplitude by changing the Data value.
7. Connect an oscilloscope to test point “
TP561
” (+) and
chassis ground (-).
8. Select Item no. “
13
” and adjust the black level to be
maximum amplitude by changing the Data value.
Pedestal Level
Black Level
Pedestal adjustment [PC]
4
1. Receive the 16-step gray scale computer signal with
Computer 1 [Analog RGB]
mode.
2. Enter the service mode.
3. Connect an oscilloscope to test point “
TP2531
” (+)
and chassis ground (-).
4. Select group no. “
5
”, Item no. “
7
” and adjust the ampli-
tude “a” to be
2.0
±0.1V by changing the Data value.
5. Select Item no. “
6
” and adjust the amplitude “b” to be
7.1
±0.1V by changing the Data value.
(a)
(b)
GND
NRS adjustment
3
1. Receive the 16-step gray scale computer signal with
Computer 1 [Analog RGB]
mode.
2. Enter the service mode.
3. Connect an oscilloscope to test point “
TP531
” (+)
and chassis ground (-).
4. Select group no. “
5
”, Item no. “
3
” and adjust the
amplitude “a” to be
10.0
±0.1V by changing the
Data value.
5. Connect an oscilloscope to test point “
TP501
” (+)
and chassis ground (-).
6. Select Item no. “
4
” and adjust the amplitude “a” to be
9.25
±0.1V by changing the Data value.
7. Connect an oscilloscope to test point “
TP561
” (+)
and chassis ground (-).
8. Select Item no. “
5
” and adjust the amplitude “a” to be
10.0
±0.1V by changing the Data value.
(a)
black level
black level
Black Level adjustment [PC]
6
1. Receive the 16-step gray scale computer signal with
Computer 1 [Analog RGB]
mode.
2. Enter the service mode.
3. Connect an oscilloscope to test point “
TP531
” (+)
and chassis ground (-).
4. Select group no. “
4
”, Item no. “
3
” and adjust the white
level to be minimum amplitude by changing the Data
value.
5. Connect an oscilloscope to test point “
TP501
” (+)
and chassis ground (-).
6. Select Item no. “
4
” and adjust the white level to be
minimum amplitude by changing the Data value.
7. Connect an oscilloscope to test point “
TP561
” (+)
and chassis ground (-).
8. Select Item no. “
5
” and adjust the white level to be
minimum amplitude by changing the Data value.
(a)
White Level
Video Gain adjustment [PC]
5
Содержание LC-XG110
Страница 59: ...57 IC Block Diagrams AD8185ARU Selector IC3001 AD9888KS140 A D IC201...
Страница 60: ...58 BA6920F Motor Drive IC5561 IC Block Diagrams BA6287F Motor Drive IC5501 IC5531 IC6501...
Страница 61: ...59 IC Block Diagrams BA7078AF SynC Detector IC7201 BA7655 Audio Pre amp IC001...
Страница 62: ...60 CXA2101AQ RGB Matrix IC4101 IC Block Diagrams DB7600 Sync Switch IC3021 IC3022...
Страница 63: ...61 IC Block Diagrams ICS1523M PLL IC4231 L306070D D A Sample Hold IC501 IC530 IC561...
Страница 64: ...62 M62392 D A IC3291 M62393 D A IC281 IC4881 IC Block Diagrams...
Страница 65: ...63 M62399 D A IC1501 IC1531 ML60851 USB Driver IC9801 IC Block Diagrams...
Страница 66: ...64 PW365 System Control Scan Converter IC301 IC Block Diagrams TA1318AF AFC Sync Driver IC6181...
Страница 67: ...65 TC90A69F PAL 3L Y C Separation IC2101 IC Block Diagrams TB1274AF Video Decoder IC1101...
Страница 68: ...66 TDA1517ATW Audio Output IC031 IC Block Diagrams...
Страница 101: ...MJ7 XG11000 MH7 XG21000 99 Mechanical Parts List L4 S3 S3 L10 S5 S5...
Страница 102: ...MJ7 XG11000 MH7 XG21000 100 Mechanical Parts List L11 S3 S3 L1 L1 a L1 b L12 Focus Zoom...