Electrical Adjustments
Gain adjustment [Pc]
1. Enter the service mode.
2. Receive the 16-step grey scale computer signal with
computer1 [rGB]
mode.
. Connect an oscilloscope to test point “
tP35G
” (+)
and chassis ground (-).
4. Select Group No. “
0
”, Item No. “
3
” and adjust the
amplitude “
a
” to be minimum by changing the Data
value.
5. Connect an oscilloscope to test point “
tP35r
” (+)
and chassis ground (-).
6. Select Group No. “
0
”, Item No. “
4
” and adjust the
amplitude “
a
” to be minimum by changing the Data
value.
7. Connect an oscilloscope to test point “
tP35B
” (+) and
chassis ground (-).
8. Select Group No. “
0
”, Item No. “
5
” and adjust the
amplitude “
a
” to be minimum by changing the Data
value.
(a)
White Level
Pedestal adjustment [component]
1. Enter the service mode.
2. Receive the 16-step grey scale 480i-component signal
with
computer1 [component]
mode.
. Connect an oscilloscope to test point “
tP35G
” (+)
and chassis ground (-).
4. Select Group No. “
0
”, Item No. “
0
” and change data
value to adjust the pedestal level and black level to be
the same level.
5. Connect an oscilloscope to test point “
tP35r
” (+)
and chassis ground (-).
6. Select Item No. “
1
” and change data value to adjust
the pedestal level and black level to be the same lev-
el.
1. Enter the service mode.
2. Receive the 8 color 100% color bar 480i-component
signal with
computer1 [component]
mode.
. To start the auto-calibration for Component adjust-
ment, select Group No. “
260
”, Item No. “
0
” and then
change data value from “
0
” to “
1
”. After the auto-cali-
bration completed, "OK" will appear on the screen.
4. Auto calibration adjustment [component]
Below adjustments are performed when the above
auto calibration is failed.
7. Connect an oscilloscope to test point “
tP35B
” (+)
and chassis ground (-).
8. Select Item No. “
2
” and change data value to adjust
the pedestal level and black level to be the same lev-
el.
P
edestal Lebel
Blac
k Lebel
Gain adjustment [component]
1. Enter the service mode.
2. Receive the 16-step grey scale 480i-component signal
with
computer1 [component]
mode.
. Connect an oscilloscope to test point “
tP35G
” (+)
and chassis ground (-).
4. Select Group No. “
0
”, Item No. “
3
” and adjust the
amplitude “
a
” to be minimum by changing the Data
value.
(a)
White Level
Содержание LC-XBM21
Страница 68: ...68 IC Block Diagrams MAX232ECPWRP RS 232C Driver IC3801 L3E06200P0A D A S H LCD Driver IC501 IC531 IC561...
Страница 69: ...69 IC Block Diagrams PW190 Scaler IC301 MR4010 Power OSC IC631...
Страница 71: ...71 IC Block Diagrams TB6608FNG IRIS Control IC601 TLV320AIC3105 Audio Control IC5002...
Страница 101: ...Key No Part No Description Key No Part No Description 101 Electrical Parts List KR8 XBM2100 KS8 XBM2600...
Страница 102: ...KR8BE KS8BE December 2010 Japan 2010 Eiki Internatinal Inc A key to better communications...