-42-
Electrical Adjustments
Group/
Item
Item Name
Function
Initial
Range Note
10 Temp A Warning (Eco)
Temp. A to judge the Temp Error at
Eco (Room)
46
46
41
40
30-100
11 Temp B Warning (Eco)
Temp. B to judge the Temp Error at
Eco (Panel)
60
61
55
54
30-100
12 Temp C Warning (Eco)
Temp. C to judge the Temp Error at
Eco (Lamp)
65
64
62
62
30-100
13 Temp B-A Warning (Eco)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
100
100
100
100
0-100
14 Temp C-A Warning (Eco)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
100
100
100
100
0-100
15 Temp A Warning Offset
(Temp)
Offset of Temp Error (Temp.)
Error Setting Value is increased XC at
the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
5
0-100
16 Temp B Warning Offset
(Temp)
5
0-100
17 Temp C Warning Offset
(Temp)
15
0-100
18 Temp B-A Warning Offset
(Temp)
0
0-100
19 Temp C-A Warning Offset
(Temp)
0
0-100
20 Temp A Warning Offset (Time)
Offset of Temp Error (Minutes)
Error Setting Value is increased X
minute at the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
5
0-100
21 Temp B Warning Offset
(Time)
5
0-100
22 Temp C Warning Offset
(Time)
18
0-100
23 Temp B-A Warning Offset
(Time)
1
0-100
24 Temp C-A Warning Offset
(Time)
1
0-100
25 Factory Mode
For factor use
0
0-1
Group
254
Fan Control Range Setting (Temp./Voltage)
Normal Ceiling HiLand-
Normal
HiLand-
Ceiling
0 High Fan Control Min Temp Temp Senser Control Start/End Temp.
at High
38
38
34
33
20-100
1 High Fan Control Max Temp
43
43
40
38
20-100
2 High Fan1 Min
Fan voltage value at High (unit: 0.1V)
95
95
115
115
0-255
3 High Fan1 Max
135
135
135
135
0-255
4 High Fan2 Min
85
85
130
130
0-255
5 High Fan2 Max
130
130
130
130
0-255
6 High Fan3 Min
75
75
80
80
0-255
7 High Fan3 Max
77
77
90
90
0-255
8 High Fan4 Min
9999
9999
-
9 High Fan4 Max
9999
9999
-
10 Normal Fan Control Min
Temp
Temp Senser Control Start/End Tem.
p at Normal
38
39
35
33
20-100
11 Normal Fan Control Max
Temp
43
43
40
38
20-100
12 Normal Fan1 Min
Fan voltage value at Normal (unit:
0.1V)
80
80
105
105
0-255
13 Normal Fan1 Max
125
125
125
125
0-255
14 Normal Fan2 Min
75
75
100
100
0-255
15 Normal Fan2 Max
120
120
120
120
0-255
16 Normal Fan3 Min
70
70
75
75
0-255
17 Normal Fan3 Max
75
70
80
80
0-255
18 Normal Fan4 Min
9999
9999
-
19 Normal Fan4 Max
9999
9999
-
20 Eco Fan Control Min Temp
Temp Senser Control Start/End Tem.
p at Eco
38
39
35
32
20-100
21 Eco Fan Control Max Temp
42
43
39
38
20-100
22 Eco Fan1 Min
Fan voltage value at Eco (unit: 0.1V)
60
60
95
95
0-255
23 Eco Fan1 Max
115
115
115
115
0-255
24 Eco Fan2 Min
70
70
90
90
0-255
25 Eco Fan2 Max
110
110
110
110
0-255
26 Eco Fan3 Min
53
53
58
58
0-255
27 Eco Fan3 Max
53
53
63
63
0-255
28 Eco Fan4 Min
9999
9999
-
29 Eco Fan4 Max
9999
9999
-
Group
255
Fan Start/Cooling Setting
0 Fan1 Initial Volt
Fan Start Voltage (0.1V)
70
0-255
1 Fan2 Initial Volt
70
0-255
2 Fan3 Initial Volt
70
0-255
3 Not used
9999
-
4 Fan1 Cooling Speed
Fan Voltage at Power Off (0.1V)
130
0-255
5 Fan2 Cooling Speed
130
0-255
6 Fan3
Cooling Speed
130
0-255
Содержание LC-XB42
Страница 61: ...61 IC Block Diagrams FA7701 DDC Control IC5751 AN5870 Signal Switch IC5201...
Страница 62: ...62 IC Block Diagrams FA7711 DC DC Converter IC5801 FA5502 P F Control IC601...
Страница 63: ...63 IC Block Diagrams L3E06150 D A S H LCD Driver IC501 IC531 IC561 HIN202EIB RS 232C Driver IC3801...
Страница 64: ...64 IC Block Diagrams L3E01060 Level Shift IC2501 IC2531 IC2561 L3E07111 LCD Driver Gamma Correction IC401...
Страница 65: ...65 IC Block Diagrams LM4889 Audio Output IC5031 NJW1156 Audio Control IC5001...
Страница 66: ...66 IC Block Diagrams PW190 Scaler IC301 STR Z2156 Power OSC IC651...
Страница 67: ...67 IC Block Diagrams TE7783 Parallel I O Expander IC1802...
Страница 93: ...KG3 XB4200 93 Mechanical Parts List 527 528 L13 L09 L01 L17 L06 L18 L12 L08 L05 L07 In the Optical Unit L10 L13...
Страница 95: ......
Страница 96: ...KG3BC April 2008 Japan 2008 Eiki Internatinal Inc A key to better communications...