![Eiki LC-XB100A Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/eiki/lc-xb100a/lc-xb100a_service-manual_2369457009.webp)
-9-
Maintenance
Lamp replacement
WarNING:
- For continued safety, replace with a lamp assembly of the same
type.
- Allow the projector to cool for at least 45 minutes before you open the
lamp cover. The inside of the projector can become very hot.
- Do not drop the lamp module or touch the glass bulb! The glass can
shatter and cause injury.
WarNING : turN oFF tHe uV LaMP BeFore oPeNING tHe LaMP coVer.
uSe uV radIatIoN eYe aNd SKIN ProtectIoN durING SerVIcING.
Note
- The projector cannot be turned-on with lamp cover removed, because
when the lamp cover is removed, the lamp cover switch is also re-
leased to switch off the lamp circuit.
Unplug the AC power cord. Let the projector cool for at least 45
minutes.
Loosen the three (3) screws that secure the lamp. Lift the lamp
out of the projector by using the handles.
1
3
Replace the lamp with a new one and secure the three (3)
screws. Make sure that the lamp is set properly. Push the
lamp cover and secure the screw.
4
Loosen the screw and open the lamp cover.
2
Connect the AC power cord to the projector and turn on the
projector.
5
Procedure
For continued safety, replace with a lamp of the
same type. Do not drop a lamp or touch a glass bulb!
The glass can shatter and may cause injury.
Allow a projector to cool for at least 45 minutes
before you open the Lamp Cover. The inside of the
projector can become very hot.
cautIoN
cautIoN
cautIoN
When replacing the lamp because it has stopped illuminating, there is a possibility that the lamp may be
broken.
If replacing the lamp of a projector which has been installed on the ceiling, you should always assume that the
lamp is broken, and you should stand to the side of the lamp cover, not underneath it. Remove the lamp cover
gently. Small pieces of glass may fall out when the lamp cover is opened. If pieces of glass get into your eyes
or mouth, seek medical advice immediately.
order rePLaceMeNt LaMP
type No.
Poa-LMP131
Service Parts No.
610 343 2069
Lamp Screw
Handles
Screw
Screw
Screw
Lamp Cover
Содержание LC-XB100A
Страница 23: ... 23 Optical Parts Disassembly Relay lens disassembly Relay lens Relay lens Ass y Fig 8 ...
Страница 65: ... 65 IC Block Diagrams FA5550NG P F Control IC621 XR16L5701IL24 UART IC9885 ...
Страница 66: ... 66 IC Block Diagrams MAX232ECPWRP RS 232C Driver IC3801 L3E06170 D A S H LCD Driver IC501 IC531 IC561 ...
Страница 69: ... 69 IC Block Diagrams MR4010 Power OSC IC631 PIC18F67J60 LAN CONTROL IC8801 ...
Страница 70: ... 70 IC Block Diagrams FA7703 DC DC Converter IC7811 Sil9127 HDMI Receiver IC8001 ...
Страница 97: ...KB5 XB100A00 KG5 XB200A00 97 Mechanical Parts List L14 Projection Lens Projection Lens ...
Страница 101: ...KB5 XB100A00 KG5 XB200A00 101 Mechanical Parts List ...
Страница 102: ... KB5BE KG5BE December 2009 Japan 2009 Eiki Internatinal Inc A key to better communications ...
Страница 114: ...A10 SCH_KD5AE NO DATA ...