background image

2.4G conference microphone system 

 

1

 

 

 

 

 

WIRELESS CONFERENCE SYSTEM 

                                                                                                              EMMU02 USER MANUAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 

Without the agreement of EIKI any reading, use, disclosure, copying or distribution of all or 

  parts of this file or associated attachments is strictly prohibit

 

 

 

Содержание EMMU02

Страница 1: ...rophone system 1 WIRELESS CONFERENCE SYSTEM EMMU02 USER MANUAL Without the agreement of EIKI any reading use disclosure copying or distribution of all or parts of this file or associated attachments i...

Страница 2: ...sts Unit Inventory 9 Microphone Unit Inventory 9 Accessories 10 Chapter 5 Installation Guide System components 12 System Installation 12 Chapter 6 Debugging System Connected and installation 14 Camera...

Страница 3: ...y operator C Parts damage or loss caused by disassembling the product by non authorized personnel 13 Use ONLY specified connection cable to connect the system equipment 14 Turn off the power supply an...

Страница 4: ...0 2483MHz no need complex cable installation no need troublesomely frequency application 2 Digital encryption self adaption frequency hopping spread spectrum technology high confidentiality 3 Configur...

Страница 5: ...ards this chapter must have professional and technical qualified engineering staff responsible for this content it is not important to the user the user does not need to reading As the supply voltage...

Страница 6: ...needs to be installed under the circuit standard electrical system standards Note cable away from the following places In order to avoid hum or interference generated by the electromagnetic induction...

Страница 7: ...information and microphone state 4 Multi function keys 5 12V 17V DC power input socket inside positive external negative 6 Mixed audio signal output socket 7 Balanced audio signal output socket 8 Cent...

Страница 8: ...up and shutdown functions 5 Display screens to show microphone id 6 Light indicator 7 Headphones port 8 Headphones volume control button 9 Power button n EMD02Delegate Microphone Unit Functionality 1...

Страница 9: ...ual warranty card and other accessories Conference microphone unit will be good protect in a block of foam reduces damage in an accident n Hosts Unit Inventory Figure 9 1 NAME MODEL QUANTITY UNIT Conf...

Страница 10: ...repancies please contact supplier n Accessory EM63 Directive Antenna Connected to the main unit EMMU02 directly no need any external power supply Transmission range 30m Directional Installed in the mi...

Страница 11: ...gnal amplification so make the microphone connection to be more stable Dimensions 68 5X51X23mm SP33 Charger charge 8pcs battery one time Charges up to 8pcs AA or 8pcs AAA World wide voltage adaptable...

Страница 12: ...nto Omni directional antenna and directional antenna base on requirement of different venues Do first the first connection now Omni directional antenna is suitable for that the conference main unit an...

Страница 13: ...ntenna is used when the conferment main unit and the microphone are in different rooms Leads directly from the control room to the meeting room put the antenna box on the wall Figure 13 1 3 Using a sp...

Страница 14: ...nd limitations of site layout 1 Do the first connection now Omni directional antenna is suitable for that the conference main unit and microphone use in one room And it can get the singe 360 degree ge...

Страница 15: ...t reliable power supply properly note remove the battery If you don t use microphone for a long time have to take out of iron pan n Camera connection Camera communication is RS 485 the communication p...

Страница 16: ...rophone and the No 3 camera is trackingNo 20 microphone to another microphones Camera ball preset settings Control by a computer or camera ball equipment and setup the preset Match Camera ball preset...

Страница 17: ...udio output The main output volume of this system is 600MV under working state turn on 4 pcs microphone open state of the four microphone to speak to the host of the volume is raised to 20 gradually i...

Страница 18: ...MODE FIFO MODE LIMITED MODE LIMITED TIME MODE CHAIRMAN B Allows up to 4 people at the same time to discuss speech through the setting which can be set to 1 2 3 4 C CH CH1 CH2 CH3 CH4 meaning that the...

Страница 19: ...ct the required mode and then press the ENTER button to determine and save the system will return to standby mode If you choose the TIME LIMITED mode continue to set the hours minutes and seconds As s...

Страница 20: ...is the range of 1 4 and then press ENTER button to determine and save the system will return to standby mode 6 Microphone unit setting method The setting is to be used for all microphone units in the...

Страница 21: ...protocol settings On the host front panel and press the ENTER key four times the LCD display of host video communication protocol is highlighted as shown below Press UP or DOWN button to select the c...

Страница 22: ...system standby or speech state directly press the VOL or VOL button to adjust the volume After the volume is set press the exit button or wait for 15 seconds without any action and the system will ex...

Страница 23: ...aud rate Please reset communication protocol baud rate of system controller and camera Suggest using PELCO P 9600 Above information is only for reference If have other problems please contact distribu...

Страница 24: ...Pickup distance 30m 5m Use 11 dB antenna in visible distance Audio output amplitude 0dB 20CM Frequency response 100Hz 18KHz THD SNR 80 dB Power supply 2 4 3V DC sensitivity 57dB 2dB Chairman unit elec...

Страница 25: ...s and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that int...

Страница 26: ...2 4G conference microphone system 25 Copyright by EIKI Last revision 10 2016...

Отзывы: