background image

EiconCard P92 Installation Guide    23

International Regulatory Information

Regulatory Information for the USA:
FCC Warning

Warning: Changes or modifications to this unit not expressly approved by 
Eicon Technology Corporation could void the user's authority to operate the 
equipment.

Note: This equipment has been tested and found to comply with the limits for a 
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are 
designed to provide reasonable protection against harmful interference in a 
residential installation. This equipment generates, uses and can radiate radio 
frequency energy and, if not installed and used in accordance with the instructions, 
may cause harmful interference to radio communications.

However, there is no guarantee that interference will not occur in a particular 
installation. If this equipment does cause harmful interference to radio or television 
reception, which can be determined by turning the equipment off and on, the user is 
encouraged to try to correct the interference by one or more of the following 
measures:

• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which

the receiver is connected.

• Consult the dealer or an experienced radio/TV technician for help.
• This unit requires shielded cables to comply with the FCC Class B emissions

limits. Use of unshielded interface cables is prohibited.

Regulatory Information for Canada

NOTICE: The Industry Canada label identifies certified equipment. This 
certification means that the equipment meets certain telecommunications network 
protective, operational and safety requirements. Industry Canada does not guarantee 
the equipment will operate to the user’s satisfaction.

Before installing this equipment, users should ensure that it is permissible to be 
connected to the facilities of the local telecommunications company. The equipment 
must also be installed using an acceptable method of connection. In some cases, the 
company’s inside wiring associated with a single line individual service may be 
extended by means of certified connector assembly (telephone extension cord). The 
customer should be aware that compliance with the above conditions may not prevent 
degradation of service in some situations.

Repairs to certified equipment should be made by an authorized Canadian 
maintenance facility designated by the supplier. Any repairs or alterations made by 
the user to this equipment, or equipment malfunctions, may give the 
telecommunications company cause to request the user disconnect the equipment.

203086-1.FM5  Page 23  Friday, February 28, 1997  10:35 AM

Содержание EiconCard P92

Страница 1: ...EiconCard P92 for PCI Compatible Bus Installation Guide 203 086 01 ...

Страница 2: ...cations at the address given below or by electronic mail to techpub eicon com Eicon Technology may use or distribute whatever information you supply in any way it believes appropriate without incurring any obligations to you Copyright 1997 Eicon Technology Corporation All rights reserved including those to reproduce this publication or parts thereof in any form without permission in writing from E...

Страница 3: ...Indicators 8 Interface Specifications 9 The V 24 Interface 10 The V 35 Interface 12 The EIA 530 Interface 14 The V 36 RS 449 Interface 16 The X 21 Interface 18 Back to Back Connections 20 Cable Construction Information 21 Technical Specifications 22 International Regulatory Information 23 Limited Warranty 27 ...

Страница 4: ...4 EiconCard P92 Installation Guide ...

Страница 5: ...ss to WAN lines Direct connections to a host computer or to another EiconCard are also supported Hardware Features The EiconCard P92 features a 10MHz Hitachi 64570 controller and 512 KB of on board RAM It has two independent Very High Speed Interface VHSI ports supporting full duplex communications over a V 24 V 35 EIA 530 V 36 RS 449 or X 21 interface at speeds of up to 2 Mbps per port depending ...

Страница 6: ...d P92 contains a test program to verify the card s integrity Consult the documentation supplied with this software for details 4 Configure the EiconCard P92 Before you can use the EiconCard P92 you must configure it to work with your communications software The documentation which came with this software contains complete instructions on how to configure the card During configuration note the foll...

Страница 7: ...nformation on making your own cables see Interface Specifications on page 9 Table 1 Standard Interface Cables To use an interface simply install the appropriate cable The EiconCard P92 recognizes the cable and automatically prepares the port for that interface Consult the documentation which came with your networking software for more information about port configuration Interface Connection Part ...

Страница 8: ...orking software for instructions on how to load a configuration file and how to start a connection Rapid Flash stays on for 1 2 second The connection has not been established Either the port is loading OR there is no response from the destination device OR the EiconCard P92 is waiting for a VHSI cable to be connected to the port Verify that the cable is properly connected to the port If the light ...

Страница 9: ...and signalling EIA RS 232 C Electrical and signalling ISO 2110 Connector type for the DCE side of a V 24 VHSI Modem Cable V 35 CCITT V 28 Some signals for electrical CCITT V 35 Some signals for electrical and signalling ISO 2593 Connector type for the DCE side of a V 35 VHSI Modem Cable EIA 530 RS 422 Electrical RS 423 Electrical ISO 2110 Connector type for the DCE side of a EIA 530 VHSI Modem Cab...

Страница 10: ...PGND Protective Ground Common 101 2 TXD Transmit Data Output 103 3 RXD Receive Data Input 104 4 RTS Request to Send Output 105 5 CTS Clear to Send Input 106 6 DSR Data Set Ready Input 107 7 SGND Signal Ground Common 102 8 DCD Data Carrier Detect Input 109 15 TCLK Transmit Clock DCE Input 114 17 RCLK Receive Clock Input 115 18 TEST Local Loopback Activation Output 141 20 DTR Data Terminal Ready Out...

Страница 11: ...truct a VHSI V 24 cable For the additional information required to construct your own cables see Cable Construction Information on page 21 Figure 3 VHSI V 24 Connections 7 VHSI V 24 23 35 DRAINWIRE 1 BRAID 7 24 9 5 11 6 12 2 13 8 15 15 16 17 18 22 20 3 21 18 25 4 30 20 33 21 34 25 1 2 3 19 5 17 6 10 23 35 24 28 8 14 26 32 ...

Страница 12: ...uest to Send Output 105 D CTS Clear to Send Input 106 E DSR Data Set Ready Input 107 F DCD Data Carrier Detect Input 109 H DTR Data Terminal Ready Output 108 J RI Ring Indicator Input 125 L TEST Local Loopback Activation Output 141 N RLB Remote Loopback Output 140 P TXD Transmit Data Output 103A R RXD Receive Data Input 104A S TXD Transmit Data Output 103B T RXD Receive Data Input 104B U CLK Trans...

Страница 13: ...ruct a VHSI V 35 cable For the additional information required to construct your own cables see Cable Construction Information on page 21 Figure 5 VHSI V 35 Connections VHSI V 35 DRAINWIRE 5 23 6 24 10 18 8 U 26 W 9 D 11 E 13 F 18 J 21 L 25 C 30 H 33 34 36 BRAID N NN B A Y AA R T V X P S TWISTEDPAIRS MANDATORY 1 3 19 14 32 ...

Страница 14: ...t Ready Input 107A CC A 7 SGND Signal Ground Common 102B AB 8 DCD Data Carrier Detect Input 109A CF A 9 RTXC Receive Clock DCE Input 115B DD B 10 DCD Data Carrier Detect Input 109B CF B 11 CLK Transmit Clock DTE Output 113B DA B 12 TRXC Transmit Clock DCE Output 114B DB B 13 CTS Clear to Send Output 106B CB B 14 TXD Transmit Data Output 103B BA B 15 TRXC Transmit Clock DCE Input 114A DB A 16 RXD R...

Страница 15: ...0 cable For the additional information required to construct your own cables see Cable Construction Information on page 21 Figure 7 VHSI EIA 530 Connections VHSI EIA 530 DRAINWIRE 4 22 5 23 6 24 7 25 8 17 26 9 9 5 27 13 11 6 29 22 12 20 30 23 13 8 31 17 35 21 21 33 34 BRAID 10 24 11 18 25 2 14 15 12 3 16 4 19 TWISTEDPAIRS MANDATORY 7 1 2 19 1 ...

Страница 16: ...utput 105A 8 RTXC Receive Clock DCE Input 115A 9 CTS Clear to Send Input 106A 10 TEST Local Loopback Activation Output 141A 11 DSR Data Set Ready Input 107A 12 DTR Data Terminal Ready Output 108A 13 DCD Data Carrier Detect Input 109A 14 RLB Remote Loopback Output 140A 15 RI Ring Indicator Input 125A 17 CLK Transmit Clock DTE Output 113A 18 TI Test Indicator Input 142A 19 GND DTE Common Return Comm...

Страница 17: ...e For the additional information required to construct your own cables see Cable Construction Information on page 21 Figure 9 VHSI V 36 RS 449 Connections VHSI V 36 RS 449 DRAINWIRE 4 22 5 23 6 24 7 25 8 8 26 26 9 9 27 27 11 11 29 29 12 12 30 30 13 13 31 17 35 18 21 10 33 34 20 BRAID 31 17 35 15 14 18 4 22 5 23 6 24 7 25 TWISTEDPAIRS MANDATORY 19 1 2 19 37 ...

Страница 18: ...ignals Pin Signal Name Direction CCITT 1 15 PGND Protective Ground Common 101 2 T A Transmit Data Output 103A 3 C A Control Signal Output 105A 4 R A Receive Data Input 104A 5 I A Indication Input 109A 6 S A Signal Element Timing Input 115A 7 B A Byte Timing Input 114A 8 SGND Signal Ground Common 102 9 T B Transmit Data Output 103B 10 C B Control Signal Output 105B 11 R B Receive Data Input 104B 12...

Страница 19: ... required to construct a VHSI X 21 cable For the additional information required to construct your own cables see Cable Construction Information on page 21 Figure 11 VHSI X 21 Connections VHSI X 21 1 19 4 22 5 23 6 24 8 26 11 29 12 12 3 30 10 8 1 9 7 14 4 11 6 13 5 TWISTEDPAIRS MANDATORY 2 DRAINWIRE BRAID ...

Страница 20: ...ck operations are conducted through the V 36 interface For the additional information required to construct your own cables see Cable Construction Information on page 21 Figure 12 VHSI VHSI Connections VHSI VHSI DRAINWIRE 4 22 6 24 26 23 5 8 13 27 31 25 11 12 29 30 12 11 30 29 7 13 31 BRAID 9 27 25 5 6 24 4 22 17 35 TWISTEDPAIRS MANDATORY 19 7 9 17 35 8 26 23 1 1 2 19 2 ...

Страница 21: ...ected to the connector case and shell at each end of the cable The braid must be connected through its full circumference Wires identified under the heading Twisted Pairs must be paired If you do not install twisted pairs correctly the cable will not work Type of Connectors The VHSI port accepts a high density 36 pin male cable connector The types of connector used on the interface specific end of...

Страница 22: ... VHSI ports connect to 36 pin high density male connectors Support for V 24 V 35 EIA 530 and V 36 RS 449 X 21 with V 11 X 27 signalling Internal or external clocking DTE or DCE or split transmit internal receive external Performance 2 Mbps full duplex per physical port Power Requirements 1 25 A 5V 50 mA 12V 25 mA 12V Environmental Requirements Operating temperature 0 C to 50 C Operating humidity 0...

Страница 23: ...rcuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This unit requires shielded cables to comply with the FCC Class B emissions limits Use of unshielded interface cables is prohibited Regulatory Information for Canada NOTICE The Industry Canada label identifies certified equipment This certification means that the equipment...

Страница 24: ... and Low Voltage Directives 91 263 EEC 89 336 EEC and 72 23 EEC as amended by Directive 93 68 EEC Safety Status SELV No voltages within this equipment exceed SELV voltages All interconnection points and ports are SELV User Installer Instructions for the United Kingdom EiconCard P92 Communications Board Important Safety Considerations When Installing Into A Host Computer System The EiconCard P92 is...

Страница 25: ...ce which is the shortest distance in air between two points Y shows the creepage path along surfaces between the same two points Figure 13 Typical Installation Power Consumption Check that power supply will not be overloaded Maximum power consumption of the board is stated on page 22 The user should check that the total power drawn by the host computer the EiconCard P92 and any other peripherals d...

Страница 26: ...26 EiconCard P92 Installation Guide Regulatory Information for Japan Eicon Technology Corporation EiconCard P92 JATE approval numbers D97 K002 0 N97 N009 0 N97 K003 0 Date of approval February 19 1997 ...

Страница 27: ... should be delivered to Eicon Technology with proof of purchase If the delivery is by mail you agree to insure the Product or assume the risk of loss or damage in transit You also agree to prepay shipping charges to Eicon Technology and to use the original shipping container or equivalent EICON TECHNOLOGY HEREBY DISCLAIMS ALL OTHER EXPRESSED AND IMPLIED WARRANTIES FOR THIS PRODUCT INCLUDING BUT NO...

Страница 28: ......

Страница 29: ...iguration Difficult Easy Performance Poor Excellent Workmanship Poor Excellent Installation Guide Accuracy Low High Organization Confusing Clear Readability Difficult Easy Presentation Poor Excellent Please return this form to Eicon Technology Corporation Attention Corporate Publications 9800 Cavendish Blvd Montreal Quebec Canada H4M 2V9 E mail techpub eicon com Fax 514 745 5588 Tel 514 745 5500 ...

Страница 30: ......

Страница 31: ......

Страница 32: ...Printed in Canada ...

Отзывы: