background image

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion. As this is a life safety device we strongly recommend that you don’t change the 

configuration parameters as this may effect the performance of the product.

Limitations of the Z-Wave System

1. Alarms are not wirelessly interlinked to each other.
2. Only the initiating Alarms will sound.
3. The Z-Wave protocol is not a life safety protocol and should not be relied upon for life safety.
4. If your internet connection is lost, communication from your 3rd party controller (i.e. to cloud or mobile devices) may not be 

possible. Your Alarm will still continue to operate as a stand alone Alarm and does not rely on an internet connection to do so.

Command Classes

Supported Command Classes

•  Basic (version 1)
•  Binary Sensor (version 2)
•  Association Group Information (version 1)
•  Device Reset Locally (version 1)
•  Z-Wave Plus Information (version 2)
•  Configuration (version 1)
•  Alarm (version 5)
•  Manufacturer Specific (version 2)
•  Powerlevel (version 1)
•  Battery (version 1)

•  Association (version 2)

•  Version (version 2)

•  Wake-up (version 2)

Controlled Command Classes

•  Basic (version 1)

Z-Wave Technical Data

Wireless Module Battery type

Powered from Alarm Battery

Frequency

@ 908.42 MHz , FCC part 15

Wireless Range

up to 100m outdoor, 40m in buildings

Explorer Frame Support

Yes

SDK

6.51.6

Device Network Role

Sleeping Reporting Slave (SRS)

Device Type

Sensor

Routing

No

FLiRs 

No

FCC

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.

ISED

This device complies with ISED’s license-exempt RSSs. Operation is subject to the following two conditions:
(1) This device may not cause interference; and

(2) This device must accept any interference, including interference that may cause undesired operation of the device.

P/N B18821 Rev2

© Ei Electronics 2017

CARBON

MONOXIDE

ALARM

ALARM

FAULT

POWER

3

Please return to:

Customer Service

Ei Electronics US, Inc

2 Tunxis Road, Suite 209

Tariffville, Connecticut 0608

web: www.ei-electronics.com