7. Getting your RadioLink Base Serviced

If your RadioLink Relay fails to work after your have carefully
read all the instructions, checked that the unit has been
installed correctly, and is receiving AC power (green light on)
contact Customer Assistance at the nearest address given at
the end of this leaflet.  If it needs to be returned for repair or
replacement, open cover and turn off rechargeable cells with
slide switch (see fig 1b).  Put the RadioLink Relay in a padded
box and send it to “Customer Assistance and Information” at
the nearest address given on the unit or in this leaflet.  State
the nature of the fault, where the RadioLink Base was pur-
chased and date of purchase.

8. Five Year Guarantee

Ei Electronics, guarantees this Ei 428 RadioLink Relay for five
years from date of purchase against any defects that are due
to faulty materials or workmanship.  This guarantee only
applies to normal conditions of use and service, and does not
include damage resulting from accident, neglect, mis-use,
unauthorised dismantling, or contamination howsoever
caused.  This guarantee does not cover costs associated with
the removal and/or installation of units.  If this RadioLink
Relay should become defective within the guarantee period, it
must be returned to Ei Electronics, with proof of purchase,
carefully packaged, and with the problem clearly stated.  (see
“Getting Your RadioLink Relay Serviced”).  We shall at our
discretion repair or replace the faulty unit.

Do not interfere with the RadioLink Relay or attempt to tam-
per with it.  This will invalidate the guarantee, but more impor-
tantly may expose the user to shock or fire hazards.  This
guarantee is in addition to your statutory rights as a con-
sumer.

9. Technical Specification

Mains: 230 VAC, 40mA, 50HZ, 0.8W
Mains Indicator: Green LED lights continuously (apart from
when it switches momentarily to red as outlined below) 
Battery Back-Up: Rechargeable Built-In Lithium Cells
(operates for up to 2 months in standby)
Approvals: Complies with EMC, Electrical Safety and Radio
Regulations  – including requirements of the RTTE Directive
Compatibility 1999/5/EC (RF Performance to EN300220-3,
EMC to EMC 301489-3) – independently tested 
Humidity Range: 15% to 95% RH (non-condensing)
Radio Frequency: 868.499 MHz (Regulated 1% duty cycle band)
RF Power: +5dBm
Range: 150 meters (minimum) in free space

RF RECEPTION
Alarm Signal Reception: 
Switches latching relay for 60 sec-
onds (with switch in continuous mode) unless it receives an

6

www.acornfiresecurity.com

www.acornfiresecurity.com

Содержание Ei428SK

Страница 1: ...will switch when fire is detected but will automatically switch back after 5 sec onds This is commonly used with warden call systems where only momentary short circuit signalling is required 2 Installation WARNING Mains powered Ei428 RadioLINK Relay modules should be installed by a qualified electrician in accordance with the Regulations for Electrical Installations published by the Institution of...

Страница 2: ...or copper earth wire to any terminal 6 Connect the wires to the required relay contacts for con trolling the auxiliary device The contacts are isolated and are rated at 250VAC 5 amps resistive 2 MODEL Ei428 WARNING DISCONNECT MAINS BEFORE REMOVAL RADIOLINK RELAY HOUSE CODE SWITCH INDICATOR LIGHT GREEN MAINS RED HOUSE CODING OR LOW BATTERY COVER ATTACHMENT SCREWS Figure 1a RECHARGEABLE CELLS ON OFF...

Страница 3: ... House Code Mode see relevant user instructions within 15 minutes before the timeout period expires 11 Check that all the RadioLINK units have communicated with each other by counting the number of times the light flashes on each unit in turn the light will flash red on the Ei428 relay modules amber on the Ei168 bases and blue on the Ei405 405TY For example 3 units in the system should have 3 flas...

Страница 4: ... light comes on and then flashes slowly Then house code all units again in their final positions as indicated above The radio link interconnection should then be re checked again 4 Limitations of Radio Communications Ei Electronics radio communication systems are very reliable and are tested to high standards However due to their low transmitting power and limited range required by regulatory bodi...

Страница 5: ...p Cells It is important to check that the rechargeable cells in the Ei428 Relay module are switched on charged and capable of pow ering the system i Check that the green light is on and that it is not flashing red once every 10 seconds If it is this indicates that either the rechargeable cells in the RadioLink Relay are not con nected or depleted Disconnect the mains supply Remove the cover and ge...

Страница 6: ...nits If this RadioLink Relay should become defective within the guarantee period it must be returned to Ei Electronics with proof of purchase carefully packaged and with the problem clearly stated see Getting Your RadioLink Relay Serviced We shall at our discretion repair or replace the faulty unit Do not interfere with the RadioLink Relay or attempt to tam per with it This will invalidate the gua...

Страница 7: ...7 P N A15267 Rev 0 Ei Electronics 2004 www acornfiresecurity com www acornfiresecurity com ...