Instructions

Read and retain carefully for as long as the product is being used. It contains vital information on the operation 

and installation of your Module. The leaflet should be regarded as part of the product.
If you are just installing this Module, the leaftet must be given to the householder. The leaflet is to be given to 

any subsequent user.

Ei100MRF Module

(for use with eSeries Alarms only)

RadioLINK

+

 Module Ei100MRF

for Mains Powered Smoke / Heat Alarms
Ei160e / Ei2110e Series

Содержание Ei100MRF

Страница 1: ...tion of your Module The leaflet should be regarded as part of the product If you are just installing this Module the leaftet must be given to the householder The leaflet is to be given to any subsequent user Ei100MRF Module for use with eSeries Alarms only RadioLINK Module Ei100MRF for Mains Powered Smoke Heat Alarms Ei160e Ei2110e Series ...

Страница 2: ......

Страница 3: ...res Indicator Summary System Examples Testing the system Interconnected Carbon Monoxide Alarms and Smoke Alarms RadioLINK Troubleshooting Technical Specifications Guarantee Limitations of Radio Communications Table of Contents 3 4 10 12 13 15 16 17 18 19 19 page ...

Страница 4: ...i100MRF module attached to that Alarm will transmit an RF signal that will activate the sounders in all other Alarms in the system The Ei100MRF module is plugged into the rear of the base of an Ei160e or Ei2110e series Alarm RF communication through this module eliminates the need to install long interconnect wires between all the Alarms on different floors in different rooms The Ei100MRF is power...

Страница 5: ...half of the Alarm away away from the screwdriver in the direction of the arrow on the cover see Figure 1 below CAUTION The existing hard wired interconnection may need to be disconnected at this point refer to the Installation section in the Alarm instruction manual If a hard wired connection and an RF connection exist between the SAME two Alarms a continuous Alarm loop signal may occur 4 Installa...

Страница 6: ...3 of its length is inserted Fig 2a Then hold the module housing Fig 2b plug it into the Alarm being careful to align the pins and keeping them perpendicular to the base as the module is inserted Fig 2c Ensure the module is fully home by checking that it is flush with the surrounding Alarm housing Fig 2d 5 Pin Alignment Pin Alignment Figure 2a Figure 2b Figure 2c ...

Страница 7: ...ocedure for all alarms in the system and any RF accessories such as the Ei450 Alarm Controller Check to ensure all RF devices have been successfully House Coded This can be done by counting the number of blue flashes on each RF Module The number of flashes should correspond to the number of RF devices in the system i e 4 flashes if there are 4 devices in the system N B We recommend for ease of ins...

Страница 8: ...7 Figure 4 blue red green LED Figure 3 ...

Страница 9: ...unication issue it may be necessary to reset factory reset and House Code the system again To do so press and hold the House Code button until you see a flashing blue light on the Alarm cover approx 7 seconds release immediately Repeat this procedure on all Alarms Removing the Ei100MRF Module If it is necessary to remove or replace an RF Module already fitted to an Alarm it can be taken out by fir...

Страница 10: ...9 Figure 5b Figure 5c ...

Страница 11: ...ly using a screwdriver press and hold the House Code button of one of the previously installed Alarms until you see all colours flashing red blue green Immediately release the button This Alarm will now send an RF message to all the previously installed compatible devices to re enter House Code mode Similarly install and put the new Alarm you wish to add to the system into House Code mode see Inst...

Страница 12: ...nt section on the RadioLINK Monitoring feature 3 Data Extraction The Ei100MRF RadioLINK Module is equipped with a feature that allows for the extraction of information from an Ei Electronics Compatible Alarm using an Ei Electronics download device Once the system has been set up information can be accessed securely from within or outside a property if access is an issue The event log can contain v...

Страница 13: ...Off Rapid flashing followed by single flash Off Off Off Press Release on Solid Blue House code Exit 3 5 Sec flash Off Off Off Remote House Coding Press Release on Multi Colour Flashing Rapid flashing followed by 3 5 Sec flash Off Off Off Power Up Blue LED Red LED Green LED Sounder Alarm Head Removal Full Sound Normal Operation Standby 1 flash 1 flash 3 5Secflashfollowedbyflashevery10Sec 3 5 Sec fl...

Страница 14: ...adioLINK Smoke Alarm RadioLINK System RF System RadioLINK RadioLINK RadioLINK Smoke Alarm RadioLINK Heat Alarm RadioLINK Smoke Alarm RadioLINK Smoke Alarm Note Remote House Coding Monitoring Data Extraction only available on RadioLINK Alarms RadioLINK Smoke Alarm RadioLINK Heat Alarm RF Tool Data Extraction ...

Страница 15: ...rdwired Smoke Alarm RadioLINK Smoke Alarm RadioLINK Ei2110e MultiSensor Alarm RF Tool Data Extraction RadioLINK Hardwired Hybrid System N B In Hybrid systems we recommend up to 6 Alarms on the hard wire interconnection line and the link Alarm be an Ei2110e MultiSensor Alarm ...

Страница 16: ...al works 5 After renovations to the house To test an individual Alarm press and hold the test button until the horn sounds and the red light flashes This will ensure that the sensor electronics and sounder are working To test the RadioLINK system press and hold the test button on one of the Alarms The blue LED from the Ei100MRF will illuminate for approximately 3 5 seconds Continue to hold the tes...

Страница 17: ...ing the alarm to be heard throughout the residence When a system alarms check to see which unit has its red light flashing rapidly this it the source of the alarm If it is a Carbon Monoxide Alarm ventilate the residence and follow the instructions in the Carbon Monoxide Alarm manual If it is a Smoke Alarm evacuate the residence and follow the instructions in the Smoke Alarm manual For added conven...

Страница 18: ... g move them away from metal surfaces or wiring After making these changes to the RF signal path the RadioLINK signals may still not be reaching all the Alarms in your system even though they have already been House Coded successfully see Section on Limitations of Radio Communications It is important to check that all Alarms are communicating in their final installed positions If Alarms are rotate...

Страница 19: ... Humidity Interconnect Up to 12 RadioLINK or RadioLINK modules Optional Accessories Ei407 Manual Call Point Ei428 Relay Module Ei414 Fire CO Alarm Interface Ei450 RadioLINK Alarm Controller Approvals RF performance to EN 300 220 1 in accordance with EN 300 220 2 EMC performance to EN 301 489 1 in accordance with EN 301 489 3 We recommend for ease of installation and RF communication that up to 12 ...

Страница 20: ...m clearly stated We shall at our discretion repair or replace the faulty unit Do not interfere with the Alarm or attempt to tamper with it This will invalidate the guarantee but more importantly may expose the user to shock or fire hazards This guarantee is in addition to your statutory rights as a consumer Ei Electronics radio communication systems are very reliable and are tested to high standar...

Страница 21: ...ng furniture or renovations and if so to give a warning of these and other faults 20 Hereby Ei Electronics declares that this Ei100MRF RadioLINK Module is in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC The Declaration of Conformity may be consulted at www eielectronics com compliance 0889 ...

Страница 22: ...l will prevent possible harm to the environment or to human health When disposing of this product please separate it from other waste streams to ensure that it can be recycled in an environmentally sound manner For more details on collection and proper disposal please contact your local government office or the retailer where you purchased this product Block E1 21 ...

Страница 23: ......

Страница 24: ...ile End Business Park Maesbury Rd Oswestry Shropshire SY10 8NN U K Tel 01691 664100 www aico co uk Ei Electronics Shannon Co Clare Ireland Tel 061 471277 www eielectronics com P N B18150 Rev3 Ei Electronics 2016 ...

Отзывы: