background image

 

Shannon Free Zone, Shannon, Co. Clare, Ireland. 

Ph.

+353 61 471277   

Fx.

+353 61 471053   

 

Email.

 [email protected]

 

 

Web:

 www.eielectronics.com 

E & OE  As our policy is one of continuous product development, we reserve the right to alter product details without prior notice

.       

Ei405 DataSht RevB

 

 

Model 

Ei405 RF Optical 

 

RF wireless interconnect  

 

Unique house coding feature 

 

Visual RF transmission indicator 

 

High performance optical chamber with integral 
insect screen 

 

Test/Hush button 

 

Advanced suppression and calibration technology 

 

Radio transmitter and receiver in each alarm 

 

Built in auto self test feature 

 

Low power cell warning 

 

Kitemarked to BS EN 14604:2005 

 

5 year guarantee 

 
 

Product Description 

 

The Ei405 is an Optical Smoke Alarm that runs on 9V 
alkaline battery and is part of the RadioLINK range of RF 
alarms.  The RF signal will wirelessly interconnect the 
Ei405 to other RadioLINK products  

 

The Ei405 uses advanced radio transciever technology 
with unique software coding to transmit and receive the 
radio signals.  The transmissions are frequency 
modulated (FM) and use Manchester coding to ensure 
robust signal integrity and avoid signal noise interference 
  
The RF range can be extensively improved by converting 
the alarm into a “repeater” i.e. re-transmission of the RF 
signals. The Ei405 series alarms can be used as a stand 
alone wireless interconnect system or be incorporated 
into existing home security systems 
 
The Ei405 has other advanced features such as high 
performance optical chambers fitted with integral insect 
screens to reduce the chances of false alarms, as well 
as the ability to wireless interconnect up to twelve alarms 
to allow all alarms to sound if just one of the 
interconnected alarms should be triggered. 
 
The Ei405 has built in circuitry to aid suppression of 
voltage transients and RF interference to further reduce 
the chances of false alarms under such conditions 
 
 
 

 

Operation 

 

 

The red indicator will flash every 40 seconds to 
show that the detector has performed an automatic 
self test 

 

 

In normal standby mode the blue indicator will light 
to indicate transmission of an RF signal 

 

 

In code mode, the blue indicator will flash to indicate 
the number of other RF alarms that have been 
“learned” in the system 

 

 

The red indicator will flash rapidly to show an alarm 
condition for the smoke detector 

 

 

The “Test/Hush” button will either silence false 
alarms or perform a unit self test 

 

 

In “Hush” mode the alarm enters a ten minute period 
of reduced sensitivity and the red light flashes every 
10 seconds and then resets 

 

 

When interconnected to other Ei mains powered 
alarms, an alarm on one detector will trigger all other 
interconnected alarms within one second (only the 
triggered alarm will flash a red indicator) 

 

 

The smoke detector will emit a beep and the red 
light flashes every 40 seconds to indicate that the 
battery is depleted and needs to be changed 

 
 

BATTERY POWERED 9V 

RF Communication 

Отзывы: