2

The Ei140RC series is supplied with an Easi-Fit 

base that allows very quick and simple installation 

of the Smoke Alarm, combined with simple detector 

head removal and replacement. The Easi-Fit base 

automatically connects both mains power and battery 

as the detector head slides on to the Easi-Fit base.
Up to 12 Smoke/Heat Alarms can be interconnected so 

that when one senses fire all the units alarm.
Interconnection can be achieved by hardwire or through 

a RadioLINK Base, the Ei168RC.
A green LED indicates the presence of mains power. A 

red LED will flash rapidly in an alarm scenario.
All Alarms feature a combined test/hush button.
The “Test/Hush” button will either silence false alarms 

or perform a unit self-test.
In “Test” mode the Alarm will perform a self-test and 

sound the horn. 
In “Hush” mode the Alarm will be silenced for a period 

of approximately ten minutes to overcome false alarm 

conditions. It will then automatically reset itself.

The Ei140RC series may be interconnected with any 

other Ei Electronics RadioLINK or RadioLINK

+

 products 

through fiiting onto an Ei168RC RadioLINK Base. 

This base will enable the Ei140RC series Alarms to 

communicate RF messages to other Ei Electronics 

products such as the Ei450 RadioLINK Alarm Controller 

where you can remotely locate, test and hush your 

Ei140RC Series Alarms using this wireless controller.
For detailed user instructions on using the RF 

interconnection base Ei168RC with the Ei140RC series, 

please consult the Ei168RC instruction manual.

Important Information

Do’s

Don’ts

Regularly check green mains 

indicator is lit

Do not paint your Alarm. Do 

not allow paint, water or dust 

to contaminate the Alarm

Test Weekly  –  See  testing 

and maintenance

Your  Alarm  is  powered  by 

230VAC.  Do  not  open  or 

insert anything into the Alarm

If  nuisance  alarms occur  – 

press the test/hush button to 

silence the Alarm for 10 mins

Remove or completely cover 

your Alarm  when  decorating 

to  prevent  dust  or  other 

contamination  damaging  the 

unit

Clean your Alarm regularly

RF Interconnection

Introduction to Ei140RC
Smoke/Heat Alarms

User Section

Содержание Aico Ei140RC

Страница 1: ...ith Alkaline Battery Backup Ei Electronics 2018 P N B18640 Rev2 Aico Ltd Mile End Business Park Maesbury Rd Oswestry Shropshire SY10 8NN U K Tel 01691 664100 www aico co uk Ei Electronics Shannon Co C...

Страница 2: ...self The Ei140RC series may be interconnected with any other Ei Electronics RadioLINK or RadioLINK products through fiiting onto an Ei168RC RadioLINK Base This base will enable the Ei140RC series Alar...

Страница 3: ...indicator light is on if it is off check circuit breakers fuses and wiring etc 2 Check that the red LED on the cover flashes once every 40 seconds to indicate normal operation If the memory has been...

Страница 4: ...ries becoming fully depleted This is sometimes done with holiday homes which are only occupied in the Summer The Alarms must be re attached to the mounting plates when the premises are re occupied If...

Страница 5: ...or fumes for example cooking fumes being drawn past the Smoke Alarm by an extractor If there are frequent nuisance false alarms it may be necessary to re locate the device away from the source of the...

Страница 6: ...y on a mobile phone or from a neighbour s house Make sure to call the Brigade for all fires no matter how small fires can suddenly spread Also call the Brigade even if the alarm is automatically trans...

Страница 7: ...that are due to faulty materials or workmanship This guarantee only applies to normal conditions of use and service and does not include damage resulting from accident neglect misuse unauthorised dism...

Страница 8: ...ed light flashing at the same time the chamber is defective See Cleaning your Alarm section 3 If the green mains light is on and replacing the battery or cleaning the unit has not stopped the beeps a...

Страница 9: ...government office or the retailer where you purchased this product Block E1 Ei Electronics Shannon Co Clare Ireland Nominal activation conditions sensitivity response delay response time and performan...

Страница 10: ...10...

Страница 11: ...GES SLIDE ON ALARM 3 LOCATE THE ARROW ON THE FRONT FACE OF THE ALARM THE SLOT IS LOCATED DIRECTLY ABOVE THE ARROW INSERT A FLAT BLADED SCREWDRIVER HORIZONTALLY APPROX 1cm INTO THE CENTRE OF THE REMOVA...

Страница 12: ...false alarms are minimised to ensure the units are not disabled or ignored The BS standard gives guidance on how many Alarms to install what type of Alarm to use where to position Alarms The above po...

Страница 13: ...ets or bathroom Minimum Protection LD3 Alarms in all hallways stairways and circulation areas that form part of the escape routes from the dwelling UK Requirements BS 5839 6 2013 Interconnect all Alar...

Страница 14: ...and all high fire risk areas rooms e g kitchen living rooms garages and all bedrooms apart from toilets or bathroom Interconnect all Alarms Heat Alarms located in Heat Alarms must be within 5 3m of p...

Страница 15: ...In enclosed kitchens with doors closed 5 Greatly depends on ventilation and distance from source of fumes Grade D System The mains powered Smoke and Heat Alarms with battery back up covered by these i...

Страница 16: ...tom of the detection element is above the level of any door openings Wall mounting should only be considered where close spaced beams or similar obstructions may preclude ceiling mounting It is consid...

Страница 17: ...n built in terminal block to connect it to the mains The mounting plate can be screwed directly to the ceiling Alternatively it can be screwed to a standard junction box It requires a current of 40mA...

Страница 18: ...arms should be connected on a single final circuit unless the means of interconnection is by radio signals e g RadioLINK See BS 5839 6 2013 for further information Note The Ei168RC RadioLINK Base can...

Страница 19: ...ositions which are also suitable for the surface wiring to enter and exit the alarm one next to the removable section and another directly opposite 5 Carefully align the mounting plate and screw into...

Страница 20: ...NING Do not connect these Alarms to any other model produced by another manufacturer Doing so may damage the Alarms and could result in a shock or fire hazard Wiring must be installed in compliance wi...

Отзывы: