background image

Emptying the Water Tank

Lift by the handle

Pull tank out

Remove the cover Pour the water contents

Refit the cover

Restore the tank

9

1.  When the tank is FULL the ‘FULL’ LED on the control panel will 
     illuminate and the dehumidifier will stop operating after several 
     minutes.
2.  DO NOT move the appliance while the tank is full, as this can lead 
     to water spillage and create a potential hazard.
3.  To remove the tank, grip the tank firmly by the bottom edge and 
     pull it out.  Any spillage should be dried immediately to avoid a 
     potential hazard.

NOTE:

Clean the tank using warm water with a mild detergent.  Do not use 
solvents or abrasive materials.
When handling the tank, due care is required to prevent damaging the 
float.  Do not attempt to remove the float. An incorrectly fitted or 
damaged float will prevent the dehumidifier from working.
The ‘FULL’ LED will illuminate if the tank is not fitted correctly or the 
float is damaged.

Содержание DIOXDry

Страница 1: ...USER MANUAL Please read this instruction manual in FULL before operating and keep in a safe place for future reference D E H U M I D I F I E R ...

Страница 2: ...right position only 9 Always place the unit on an even level surface 10 Ensure the unit is connected to an earthed power supply of the correct rating Refer to the rating label located at the back of the unit 11 DO NOT cover or obstruct the appliance s inlet and outlet grilles 12 Never unplug the appliance while it is working this could damage the electronic circuits 13 DO NOT use the appliance in ...

Страница 3: ...scription Control panel Air outlet Water tank Hand grip to pull out the water tank Handle Air inlet Continuous drain hole Power cord Cord tie Power cord tie hole Automatic louvre Water level viewer Air filter 2 ...

Страница 4: ...8 Power Key Timer key Louvre Swing Control key Auto Dry Mode key Laundry Mode key Timer indicators Function indicators Louvre swing indicators Water Full indicator Indicator lights up when the water tank is full or incorrectly installed Check indicator Indicator lights up when the unit has malfunctioned 3 ...

Страница 5: ...the power is restored after a power failure the appliance will continue to operate at the selected settings prior to the power failure This includes the drying mode swing function and time remaining in timer mode Note After turning the appliance OFF After turning the appliance OFF using the ON OFF button the fan will continue to run for a two minute period This is a normal procedure and helps to c...

Страница 6: ...ehumidifier operates in LOW fan speed low heater power The dehumidifier operates to achieve room conditions between 40 45 Relative Humidity Fan speed is always high the heater power is adjusted automatically MODES Heater Under 35o C Over 40o C Over 60 o C High Low Low OFF OFF OFF OFF Low Low OFF OFF OFF OFF High Low OFF OFF OFF OFF High High Low Low Low Under 55 o C Over 60 o C Under 55o C Over 50...

Страница 7: ...ically operates in low power Suitable operation for drying clothes in the Winter The fan speed is always high the heater typically operates at high power The humidity target is approximately 40 RH MODES Heater Under 15o C Over 40o C Over 40o C High High Low OFF Low Low OFF Low OFF OFF Low OFF OFF High High High High Low High Low Under 35o C Over 60 o C Under 55 o C 35 40o C 15 35o C Room Temperatu...

Страница 8: ...NG LOUVRE MODE DESCRIPTION UP FRONT WIDE HOLD The automatic louvre swings in an upward direction through 90 The automatic louvre swings in a forward direction through 60 The automatic louvre swings in a wide angle through 150 The automatic louvre stops swinging and is held at that position at the moment the button is pressed 7 ...

Страница 9: ...IMER mode 2hrs 4hrs 8hrs continuous LED OFF Press the TIMER button to set running hours 2 4 or 8 hours When the timer is set the corresponding LED s will be illuminated displaying the time remaining When no TIMER is set the LED s will be OFF ...

Страница 10: ... and create a potential hazard 3 To remove the tank grip the tank firmly by the bottom edge and pull it out Any spillage should be dried immediately to avoid a potential hazard NOTE Clean the tank using warm water with a mild detergent Do not use solvents or abrasive materials When handling the tank due care is required to prevent damaging the float Do not attempt to remove the float An incorrectl...

Страница 11: ...k 2 Using a screwdriver remove the knock out located on the back of the appliance and pass the hose through the hole 3 Attach the hose firmly to the L shaped drain connector 4 Connect the L shaped drain connector to the drain outlet 5 Rotate clockwise to fix the connector into position 6 Restore the water tank in the correct position ...

Страница 12: ...ing a soft dry cloth wipe the casing dry 4 To avoid damage to internal parts do not pour water over or into the appliance 1 Turn the appliance OFF and ensure the BS three pin plug is removed from the socket outlet 2 Remove the filter located at the back of the appliance 3 Clean the filter using clean water and allow to dry or alternatively clean using a vacuum cleaner 4 Restore the filter into the...

Страница 13: ...temperature If the dehumidifier stops operating please check the following 1 Is the power switched OFF or the three pin plug removed from the socket outlet 2 Is the FULL light illuminated Is the bucket FULL or not correctly positioned 3 Is the filter dirty Please refer to the maintenance section 4 Are the air inlet or outlet covered If you continue to experience problems please call the EHS Intern...

Страница 14: ......

Страница 15: ...s 2006 95 EG and 89 336 EEC Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check with your Local Authority or retailer for recycling advice EHS Manchester M17 1RN EHS International Ltd Guarantees this product free from defects in materials and workmanship for a period of one 1 year Should this unit be operated under conditions other t...

Отзывы: