background image

 

 

14 

Here you can obtain the predefined programs (PROG) and the 
speed of them (SPEED).You can choose PROG or SPEED by 
pressing the UP or DOWN button. You will find a program 
overview in the chapter “reference”  

Choose one of the functions and press ENTER. Then set up 
the desired value by pressing the UP or DOWN button and 
confirm again with ENTER. In the same way you can go on with 
the other values 

By pressing MODE you are able to leave the menu. 

Sound control 

Press the UP or DOWN button until SOUND MODE appears in 
the display. 

Confirm by pressing ENTER to enter the submenu 

Here you can choose the submenu SOUND to choice the 
sound active programs or you can choose SENS to set up the 
sensitivity of the built in microphone. Use the UP or DOWN 
button to choose SENS or SOUND 

Choose one of the functions and confirm with ENTER. Set up 
the desired value by pressing the UP or DOWN button and 
confirm again with ENTER. Go on with the set up in the same 
way 

By pressing MODE you are able to leave the menu. 

3.4. 

Manual colour control 

 

Press the UP or DOWN button until CIOLOUR SELECT 
appears in the display 

Confirm by pressing ENTER to enter the submenu. In this 
menu your are able to control manual the colours red green 
and blue  

With the UP or DOWN button you can take your choice 
between R, G, B and W. 

Choose one of the functions and press ENTER to confirm. Set 
up the desired value by pressing the UP or DOWN button and 
confirm again with ENTER. Go on with the set up in the same 
way. 

By pressing MODE you are able to leave the menu. 

Содержание Fusion FS-80 RGBW/1

Страница 1: ...FS 80 RGBW 1 Operating manual Bedienungsanleitung ...

Страница 2: ...Bedienungsanleitung Operating manual ...

Страница 3: ...er 14 3 1 7 Red 14 3 1 8 Green 14 3 1 9 Blue 14 3 1 10 White 15 3 1 11 Reset to Default 15 3 1 12 LED PCB 15 3 1 13 Software Version 15 3 2 DMX STEUERUNG 15 3 2 1 DMX Modes 16 3 2 2 Master Mode 17 3 2 3 Slave Mode 17 3 3 PROGRAMMAUTOMATIK 17 3 4 MUSIKSTEUERUNG 18 3 5 MANUELLE FARBANWAHL 18 4 REFERENZ 19 4 1 DMX KANALTABELLE 19 4 2 PROGRVAMME 24 4 3 SPEZIAL FUNKTIONEN MODE 2 27 4 3 1 Shutter Channe...

Страница 4: ...se und Feuchtigkeit Trennen Sie das Gerät vor dem Öffnen vom Netz Lesen Sie sich diese Bedienungsanleitung vor der ersten Inbetriebnahme des Geräts sorgfältig durch Alle Personen die mit der Aufstellung Inbetriebnahme Bedienung Wartung und Instandsetzung des Geräts betraut sind müssen eine entsprechende Qualifikation vorweisen die Vorgaben dieser Bedienungsanleitung exakt befolgen die Bedienungsan...

Страница 5: ...im Umgang mit Netzleitungen und Netzanschlüssen besondere Vorsicht Berühren Sie diese niemals mit feuchten Händen Stellen Sie sicher dass die anzuschließende Netzspannung die angegebenen Werte nicht übersteigt Vergewissern Sie sich dass eine Quetschung oder Beschädigung der Netzleitung durch scharfe Kanten ausgeschlossen ist Vergewissern Sie sich ebenfalls durch regelmäßige Überprüfungen dass Gerä...

Страница 6: ...e darauf dass Kabel nicht frei herumliegen Sie würden dadurch Ihre eigene Sicherheit und auch die Sicherheit Dritter gefährden Das Gerät darf nicht in einer Umgebung betrieben oder aufbewahrt werden in welcher mit Spritzwasser Regen Feuchtigkeit oder Nebel zu rechnen ist Feuchtigkeit oder sehr hohe Luftfeuchtigkeit kann die Isolation des Geräts reduzieren und in tödlichen elektrischen Schlägen res...

Страница 7: ...ssen Sie das Gerät nicht von Personen bedienen die darin keine Erfahrung haben Die häufigste Ursache für Funktionsstörungen stellt eine unsachgemäße Bedienung des Geräts dar Verwenden Sie zur Reinigung des Geräts niemals Lösungsmittel oder aggressive Reinigungsmittel Benutzen Sie stattdessen ein weiches und leicht angefeuchtetes Tuch Verwenden Sie zum Transport des Geräts bitte die Originalverpack...

Страница 8: ... zweite Aufhängung muss so beschaffen und angebracht sein dass bei einem Störfall der Hauptaufhängung kein Bestandteil der Installation herunterfallen kann Beim Auf Um und Abbau ist der unnötige Aufenthalt im Bereich von Bewegungsflächen auf Beleuchterbrücken unter hochgelegenen Arbeitsplätzen oder in sonstigen Gefahrenbereichen verboten Der gewerbliche Anwender hat folgende Verantwortungen für si...

Страница 9: ...ern abhängt werden ist mit Traversensystemen zu arbeiten Das Gerät darf keinesfalls so installiert werden dass es frei im Raum schwingen kann Bitte beachten Sie Geräte können beim Herabstürzen zu schwerwiegenden Verletzungen führen Haben Sie Zweifel an der Sicherheit einer möglichen Installationsform dann führen Sie die Installation des Geräts NICHT durch Stellen Sie vor der Montage des Geräts sic...

Страница 10: ...rden Ein Sicherungsfangseil welches einmal der Belastung durch einen Absturz ausgesetzt war oder das beschädigt ist darf nicht weiter als Sicherungsfangseil verwendet werden Regeln Sie den Neigungswinkel über den Montagebügel und ziehen Sie die Feststellschrauben fest an ...

Страница 11: ...80 RGBW 1 ist eine LED Leiste für den Einsatz von Wand Hintergrunds Bühnen und Raumbeleuchtungen 2 1 Rückansicht 1 Bügel für Aufhängung mit M10 Loch 2 M10 Befestigungsschraube 3 Schiene um den Bügel zu justieren 4 Controlpanel ...

Страница 12: ...1 DMX Ausgang 5 Pol 2 DMX Ausgang 3 Pol 3 DMX Eingang 5 Pol 4 DMX Eingang 3 Pol 5 Dateneingang f Softwareupdates 6 MODE Taster 7 UP Taster 8 DOWN Taster 9 ENTER Taster 10 LC Display 11 Powercon Eingang 12 Powercon Ausgang ...

Страница 13: ...Auge nicht sehr sanft wirkt Die optimierte Kurve ist wesentlich schöner verzögert aber den Dimmvorgang ganz leicht Am besten probieren sie beide Einstellungen aus um die Beste für ihre Anwendung zu finden Mit ENTER können sie eine Auswahl treffen und mit MENU bestätigen sie die Wahl Ein Stern zeigt immer an welche Einstellung gerade gewählt ist Wählen sie LINE für lineares Dimmen und Wählen sie CU...

Страница 14: ...Hier können Sie bestimmen ob das Display dauerhaft an oder aus geschalten bleiben soll Drücken Sie die UP DOWN Tasten bis ON oder OFF mit dem Stern markiert ist Bestätigen sie mit ENTER Wenn ON markiert ist bleibt das Display dauerhaft an Wenn OFF markiert ist schaltet das Display nach 10 Sek automatisch ab 3 1 5 DMX Hier können Sie entscheiden wie das Gerät reagiert wenn das DMX Signal abgezogen ...

Страница 15: ...ENTER Diese Einstellung kann nicht vom DMX Signal überschrieben werden Sie gilt mit höchster Priorität 3 1 8 Green Stellen Sie den maximalen Output der Farbe Grün ein Drücken Sie ENTER um den Wert zu verändern Drücken Sie die UP DOWN Tasten um den maximalen Lichtoutput von 0 100 einzustellen Bestätigen Sie mit ENTER Diese Einstellung kann nicht vom DMX Signal überschrieben werden Sie gilt mit höch...

Страница 16: ...ie Temperatur der LED Platine an Sollte die Temperatur über 75 C sein regelt das Gerät automatisch die Lichtleistung herunter bis die Temperatur wieder im Betriebsbereich liegt 3 1 13 Software Version Zeigt die aktuelle Software Version an 3 2 DMX Steuerung 1 Drücken Sie am Display die Tasten UP oder DOWN bis im Display DMX MODE SETUP steht 2 Bestätigen Sie mit ENTER um in das Untermenü zu gelange...

Страница 17: ...enauso verfahren Sie mit allen Einstellmöglichkeiten Die DMX Modi stellen sich wie folgt dar 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Mode 1 3 Channels 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Mode 2 4 Channels Mode 3 7 Channels 1 1 1 1 1 1 1 1 1 1 2 Mode 4 8 Channels 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 Mode 5 8 Channels 1 1 1 1 1 2 2 2 2 2 3 3 3 3 3 4 4 4 4 4 Mode 6 16 Channels 1 1 1 1 2 2 2 2 ...

Страница 18: ...men und die anderen Geräte zum Slave 3 3 Programmautomatik 1 Drücken Sie am Display die Tasten UP oder DOWN bis im Display AUTOMATIC MODE steht 2 Bestätigen Sie mit ENTER um in das Untermenü zu gelangen 3 Hier können Sie die voreingestellten Programme abrufen PROG und deren Geschwindigkeit einstellen SPEED Mit den UP und DOWN Tasten können Sie zwischen PROG und SPEED hin und her schalten Die Progr...

Страница 19: ...ieder mit ENTER Genauso verfahren Sie mit der anderen Einstellmöglichkeit 5 Mit der MODE Taste verlassen Sie das Untermenü wieder 3 5 Manuelle Farbanwahl 1 Drücken Sie am Display die Tasten UP oder DOWN bis im Display COLOUR SELECT steht 2 Bestätigen Sie mit ENTER um in das Untermenü zu gelangen Hier können Sie manuell die drei Farben Rot Grün und Blau einstellen 3 Mit den UP und DOWN Tasten könne...

Страница 20: ...Dimmer Red 2 0 255 Dimmer Green 3 0 255 Dimmer Blue 4 0 255 Dimmer white Mode 3 7 Channels CH Value Function 1 0 255 Dimmer Red 2 0 255 Dimmer Green 3 0 255 Dimmer Blue 4 0 255 Dimmer White 5 0 15 16 47 48 79 80 111 112 143 144 199 200 239 240 255 Shutter Closed Random Ramp Up Ramp Down Ramp Up Down Strobe 0 2 1Hz 1Hz 20Hz Shutter open 6 0 255 Master Dimmer 7 Special channel ...

Страница 21: ...Blue 1 4 0 255 Dimmer White 1 5 0 255 Dimmer Red 2 6 0 255 Dimmer Green 2 7 0 255 Dimmer Blue 2 8 0 255 Dimmer White 2 Mode 5 8 Channels CH Value Function 1 0 255 Dimmer Red 1 2 0 255 Dimmer Green 1 3 0 255 Dimmer Blue 1 4 0 255 Dimmer White 1 5 0 255 Dimmer Red 2 6 0 255 Dimmer Green 2 7 0 255 Dimmer Blue 2 8 0 255 Dimmer White 2 Mode 6 16 Channels CH Value Function 1 0 255 Dimmer Red 1 2 0 255 D...

Страница 22: ...te 4 Mode 7 20 Channels CH Value Function 1 0 255 Dimmer Red 1 2 0 255 Dimmer Green 1 3 0 255 Dimmer Blue 1 4 0 255 Dimmer White 1 5 0 255 Dimmer Red 2 6 0 255 Dimmer Green 2 7 0 255 Dimmer Blue 2 8 0 255 Dimmer White 2 9 0 255 Dimmer Red 3 10 0 255 Dimmer Green 3 11 0 255 Dimmer Blue 3 12 0 255 Dimmer White 3 13 0 255 Dimmer Red 4 14 0 255 Dimmer Green 4 15 0 255 Dimmer Blue 4 16 0 255 Dimmer Whi...

Страница 23: ...Blue 3 12 0 255 Dimmer White 3 13 0 255 Dimmer Red 4 14 0 255 Dimmer Green 4 15 0 255 Dimmer Blue 4 16 0 255 Dimmer White 4 37 0 255 Dimmer Red 10 38 0 255 Dimmer Green 10 39 0 255 Dimmer Blue 10 40 0 255 Dimmer White 10 Mode 9 80 Channels CH Value Function 1 0 255 Dimmer Red 1 2 0 255 Dimmer Green 1 3 0 255 Dimmer Blue 1 4 0 255 Dimmer White 1 5 0 255 Dimmer Red 2 6 0 255 Dimmer Green 2 7 0 255 D...

Страница 24: ...Blue 3 12 0 255 Dimmer White 3 13 0 255 Dimmer Red 4 14 0 255 Dimmer Green 4 15 0 255 Dimmer Blue 4 16 0 255 Dimmer White 4 77 0 255 Dimmer Red 20 78 0 255 Dimmer Green 20 79 0 255 Dimmer Blue 20 80 0 255 Dimmer White 20 ...

Страница 25: ...24 4 2 Progrvamme Program 1 4 Color Change Program 2 8 Color Fade Program 3 7 Color change Program 4 Chaser Red ...

Страница 26: ...25 Program 5 Chaser Green Program 6 Chaser Blue ...

Страница 27: ...26 Program 16 ...

Страница 28: ...TIMIZED stellen 210 214 Display auf ON schalten 215 219 Display auf OFF schalten 220 224 DMX Signalverlust auf FREEZE stellen 225 229 DMX Signalverlust auf BLACKOUT stellen 230 234 RGBW und Master auf 100 250 auf Werkseinstellungen zurücksetzen All diese Funktionen werden erst aktiv wenn der entsprechende DMX Wert mindestens 3 Sekunden aktiv bleibt Der Stick bestätigt die Änderung durch 3 maliges ...

Страница 29: ...l auch auf 255 steht Unterhalb dieses DMX Wertes können sie diverse andere Funktionen und Shuttersequenzen finden wie folgt Value Function 0 15 Shutter closed 16 47 Random shutter Slow fast 48 79 Ramp Up Slow fast 80 111 Ramp Down Slow fast 112 143 Ramp UP Down Slow fast 144 199 Strobe Pulse Effect 5s 1s linear 200 239 Strobe Effect FQ 1Hz 10Hz linear 240 255 Shutter open ...

Страница 30: ...Enter for select Enter for select ESC for release menu will mark setting Enter for select ESC for release menu will mark setting Enter for select ESC for release menu will mark setting Enter for select ESC for release menu will mark setting Enter for select ESC for release menu will mark setting Enter for select ESC for release menu will mark setting Enter for select ESC for release menu UP DOWN c...

Страница 31: ...ON X XX XXX Enter for select ESC for release menu UP DOWN change value Enter for select ESC for release menu UP DOWN change value Enter for select ESC for release menu UP DOWN change value Enter for select ESC for release menu UP DOWN change value Enter for select ESC for release menu UP DOWN change value Enter for reset ESC for release menu ESC for release menu UP DOWN UP DOWN ...

Страница 32: ...x Bxxx Wxxx COLOUR SELECT Rxxx Gxxx Bxxx Wxxx ENTER for select Enter for select ESC for release menu UP DOWN change value Mode 01 09 Slave ADD 001 512 ENTER for select Enter for select ESC for release menu UP DOWN change value ENTER for select Enter for select ESC for release menu UP DOWN change value ENTER for select Enter for select RGB ESC for release menu UP DOWN change value UP DOWN UP DOWN U...

Страница 33: ...Stromaufnahme Max 140W LEDs 20x4W 4 in 1 RGBW Abstrahlwinkel 10 NSP Gewicht 9 KG Maße 1008 x 190 x 222mm Anwendungstemperatur 0 C 40 C Schutzklasse IP 20 DMX Protokoll DMX 512 Anschlüsse XLR 3 Pin IN OUT XLR 5 Pin IN OUT PowerCon IN OUT RJ45 Farbe Schwarz ...

Страница 34: ...Operating Manual ...

Страница 35: ... 6 Master 10 3 1 7 Red 11 3 1 8 Green 11 3 1 9 Blue 11 3 1 10 White 11 3 1 11 Reset to default 11 3 1 12 LED PCB 12 3 1 13 Software version 12 3 2 DMX CONTROL 12 3 2 1 DMX modes 12 3 2 2 Master mode 13 3 2 3 Slave mode 13 3 3 AUTOMATIC PROGRAM 13 SOUND CONTROL 14 3 4 MANUAL COLOUR CONTROL 14 REFERENCE 15 3 5 DMX CHANNEL CHART 15 3 6 PROGRAMS 20 3 6 1 Special functions Mode 2 23 3 6 2 Shutter Chann...

Страница 36: ...d amplifier To avoid placing on un stable location Select a level and stable location to avoid vibration Do not use chemicals or volatile liquids for cleaning Use a clean dry cloth to wipe off the dust or a wet soft cloth for stubborn dirt If out of work contact sales agency immediately Any troubles arose remove the power plug soon and contact with an engineer for repairing do not open the cabinet...

Страница 37: ...ons are approved by a skilled person once a year Procedure The Device must be installed outside areas where persons may walk by or be seated IMPORTANT OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE including but not limited to calculating working load limits installation material being used and periodic safety inspection of all installation material and the projector If you lack these qualificatio...

Страница 38: ...tion spot Insert the end in the quick link and tighten the safety screw The maximum drop distance must never exceed 20 cm A safety rope which already held the strain of a crash or which is defective must not be used again Adjust the desired inclination angle via the mounting bracket and tighten the fixation screws DANGER TO LIFE Before taking into operation for the first time the installation has ...

Страница 39: ...deformations on the housings fixations and installations spots 3 No damages must be showed on the power supply cables material fatigue and sediments If the device is going to be cleaned please use moist lint free cloths Never use alcohol or solvents The cooling fan must be cleaned monthly To clean the interior of the device please use a vacuum cleaner or an air jet We recommend cleaning the lenses...

Страница 40: ...7 2 Unit The Fusion is a LED bar developed for wall background stage and ambient lighting 2 1 Rear Side 1 Bracket for mounting M10 Screw 2 M10 Screw 3 Rail to adjust the bracket 4 Control panel ...

Страница 41: ...nel 1 DMX output 5 pin 2 DMX output 3 pin 3 DMX input 5 pin 4 DMX Input 3 pin 5 Data input for software updates 6 Mode button 7 Up button 8 Down button 9 Enter button 10 LC Display 11 PowerCon input 12 PowerCon output ...

Страница 42: ...not very smooth The optimized curve is much more smooth but extends the dimming process just a bit Best is always to try both versions to find the best solution for the upcoming event With ENTER you can choose the mode and with MENU you can confirm the choice A star always shows which mode is chosen at the moment Chose LINE for linear dimming Chose OPTIMIZED for the optimized curve 3 1 2 Setup Mas...

Страница 43: ...rm with ENTER If ON is marked the display will stay on steady If OFF is marked the display will stay off steady after 10 seconds 3 1 5 DMX Here you can decide how the unit reacts after the DMX Signal is lost Press the UP or DOWN button until FREEZE or BLACKOUT appears in the display Confirm your choice with ENTER FREEZE means that the last released DMX signal will be kept BLACKOUT means that the u...

Страница 44: ... be overwritten by the DMX signal It has the highest priority 3 1 9 Blue Set up the maximum light output of the colour blue Press ENTER to change the value Press the UP or DOWN button to set up the maximum light output from 0 to 100 Confirm with ENTER This setting can not be overwritten by the DMX signal It has the highest priority 3 1 10 White Set up the maximum light output of the colour White P...

Страница 45: ...e menus by pressing the UP or DOWN button confirm the submenu by pressing ENTER By pressing MODE you are able to leave the menu The display is blinking if there is no DMX signal 3 2 1 DMX modes In this menu you can select the control channel quantity and the excitation You can set up also the DMX mode MODE and the DMX address ADD with the UP or DOWN button you can choose MODE or ADD Choose a funct...

Страница 46: ... It works in the automatic program the music control or in the manual control It s important to make sure that the other plugged units are working in the slave mode and that there is only one master unit in the line 3 2 3 Slave mode In this mode the unit reacts congruent to the master unit If you have plugged a few units into one line and connected them by using a DMX cable you are able to make on...

Страница 47: ...se SENS to set up the sensitivity of the built in microphone Use the UP or DOWN button to choose SENS or SOUND Choose one of the functions and confirm with ENTER Set up the desired value by pressing the UP or DOWN button and confirm again with ENTER Go on with the set up in the same way By pressing MODE you are able to leave the menu 3 4 Manual colour control Press the UP or DOWN button until CIOL...

Страница 48: ...Dimmer Red 2 0 255 Dimmer Green 3 0 255 Dimmer Blue 4 0 255 Dimmer white Mode 3 7 Channels CH Value Function 1 0 255 Dimmer Red 2 0 255 Dimmer Green 3 0 255 Dimmer Blue 4 0 255 Dimmer White 5 0 15 16 47 48 79 80 111 112 143 144 199 200 239 240 255 Shutter Closed Random Ramp Up Ramp Down Ramp Up Down Strobe 0 2 1Hz 1Hz 20Hz Shutter open 6 0 255 Master Dimmer 7 Special channel ...

Страница 49: ...Blue 1 4 0 255 Dimmer White 1 5 0 255 Dimmer Red 2 6 0 255 Dimmer Green 2 7 0 255 Dimmer Blue 2 8 0 255 Dimmer White 2 Mode 5 8 Channels CH Value Function 1 0 255 Dimmer Red 1 2 0 255 Dimmer Green 1 3 0 255 Dimmer Blue 1 4 0 255 Dimmer White 1 5 0 255 Dimmer Red 2 6 0 255 Dimmer Green 2 7 0 255 Dimmer Blue 2 8 0 255 Dimmer White 2 Mode 6 16 Channels CH Value Function 1 0 255 Dimmer Red 1 2 0 255 D...

Страница 50: ...te 4 Mode 7 20 Channels CH Value Function 1 0 255 Dimmer Red 1 2 0 255 Dimmer Green 1 3 0 255 Dimmer Blue 1 4 0 255 Dimmer White 1 5 0 255 Dimmer Red 2 6 0 255 Dimmer Green 2 7 0 255 Dimmer Blue 2 8 0 255 Dimmer White 2 9 0 255 Dimmer Red 3 10 0 255 Dimmer Green 3 11 0 255 Dimmer Blue 3 12 0 255 Dimmer White 3 13 0 255 Dimmer Red 4 14 0 255 Dimmer Green 4 15 0 255 Dimmer Blue 4 16 0 255 Dimmer Whi...

Страница 51: ...Blue 3 12 0 255 Dimmer White 3 13 0 255 Dimmer Red 4 14 0 255 Dimmer Green 4 15 0 255 Dimmer Blue 4 16 0 255 Dimmer White 4 37 0 255 Dimmer Red 10 38 0 255 Dimmer Green 10 39 0 255 Dimmer Blue 10 40 0 255 Dimmer White 10 Mode 9 80 Channels CH Value Function 1 0 255 Dimmer Red 1 2 0 255 Dimmer Green 1 3 0 255 Dimmer Blue 1 4 0 255 Dimmer White 1 5 0 255 Dimmer Red 2 6 0 255 Dimmer Green 2 7 0 255 D...

Страница 52: ...Blue 3 12 0 255 Dimmer White 3 13 0 255 Dimmer Red 4 14 0 255 Dimmer Green 4 15 0 255 Dimmer Blue 4 16 0 255 Dimmer White 4 77 0 255 Dimmer Red 20 78 0 255 Dimmer Green 20 79 0 255 Dimmer Blue 20 80 0 255 Dimmer White 20 ...

Страница 53: ...20 3 6 Programs Program 1 4 Color Change Program 2 8 Color Fade Program 3 7 Color change Program 4 Chaser Red ...

Страница 54: ...21 Program 5 Chaser Green Program 6 Chaser Blue ...

Страница 55: ...22 Program 16 ...

Страница 56: ... LINE 205 209 Set dimmer curve to OPTIMIZED 210 214 Set Display to ON 215 219 Set Display to OFF 220 224 Set FREEZE for no DMX 225 229 Set BLACKOUT for no DMX 230 234 RGBW and Master set to 100 250 recall manufacturers settings To set one of these functions the values have to be kept for minimum 3 seconds The stick confirms the setting when it flashes all LEDs 3 times ...

Страница 57: ...tter channel is on Value 255 Under this value you can find several sequences and pulse effects as described here Value Function 0 15 Shutter closed 16 47 Random shutter Slow fast 48 79 Ramp Up Slow fast 80 111 Ramp Down Slow fast 112 143 Ramp UP Down Slow fast 144 199 Strobe Pulse Effect 5s 1s linear 200 239 Strobe Effect FQ 1Hz 10Hz linear 240 255 Shutter open ...

Страница 58: ...r select Enter for select ESC for release menu will mark setting Enter for select ESC for release menu will mark setting Enter for select ESC for release menu will mark setting Enter for select ESC for release menu will mark setting Enter for select ESC for release menu will mark setting Enter for select ESC for release menu will mark setting Enter for select ESC for release menu UP DOWN change va...

Страница 59: ...ON X XX XXX Enter for select ESC for release menu UP DOWN change value Enter for select ESC for release menu UP DOWN change value Enter for select ESC for release menu UP DOWN change value Enter for select ESC for release menu UP DOWN change value Enter for select ESC for release menu UP DOWN change value Enter for reset ESC for release menu ESC for release menu UP DOWN UP DOWN ...

Страница 60: ...x Bxxx Wxxx COLOUR SELECT Rxxx Gxxx Bxxx Wxxx ENTER for select Enter for select ESC for release menu UP DOWN change value Mode 01 09 Slave ADD 001 512 ENTER for select Enter for select ESC for release menu UP DOWN change value ENTER for select Enter for select ESC for release menu UP DOWN change value ENTER for select Enter for select RGB ESC for release menu UP DOWN change value UP DOWN UP DOWN U...

Страница 61: ...r consumption Max 140W LEDs 20x4W 4 in 1 RGBW Beam angle 10 NSP Weight 9 KG Measurements 1008 x 190 x 222mm Ambient temperature 0 C 40 C Protection class IP 20 DMX protocol DMX 512 Connectors XLR 3 Pin IN OUT XLR 5 Pin IN OUT PowerCon IN OUT RJ45 Colour Black ...

Страница 62: ......