Services
Trouble Shooting
13
Services
Trouble Shooting
Problem
Causes
Solutions
No Display / Not switched on
No power to fixture
Check AC mains power and connections
Inspect connections and cables. Correct poor connections. Repair or replace
damaged cables
Check the power supply voltage.
Fixture does not respond to
DMX correctly.
Incorrect fixture DMX addressing
Check the fixture is assign to correct DMX address (See Page 9)
Incorrect DMX mode
Check fixture is set to correct DMX mode (See Page 11)
Fault on data link
check for the data link is correctly linked from the DMX source if all cables are
in good condition
Other device on DMX link defective.
Unplug eventCON® IN and OUT connectors and connect them directly
together to bypass one fixture at a time until normal operation is regained
Data transmission lines should be terminated.
Insert termination plug in OUTPUT of the last fixture on the link.
LC-Display works but no light
outputs can be generated.
Faulty DMX link
Run built-in test mode or static control mode to verify if LEDs are illuminated
Broken parts / wires / LEDs
Have fixtures serviced by an Ehrgeiz service technician
Maintenance
There are no serviceable Part inside your BabyBeam 4. If problems occur, contact your Ehrgeiz dealer or a qualified Ehrgeiz Service
technician.
Use a slightly moist and smooth cloth to clean the device. Do not use any aggressive detergents.