RCL-CXXW_EHC_Rev.0_05-12-2018
9
/
26
ELECTRIC CONNECTION
The appliance has been designed to be connected to 230V (nominal)
alternating current (AC); 50Hz power supply.
This appliance is equipped with a 1.5 m supply cord fitted with standard UK
sealed 3 pin plug that can be directly connected to a suitable electrical
sockets within the home.
Care must be taken when connecting radiators in this way not to overload
the ring main circuit within the property.
If you are unsure contact a
qualified electrician for advice.
Alternatively the supply cord can be cut to length by a Qualified Electrician
and connected to a suitable 13A DP Switched Fuse Spur installed adjacent to
the radiator. This connection unit should comply with BS 1364-4 and have a
minimum contact separation of at least 3mm. It is recommended when
connecting to a screwed terminal that the flex ends are crimped to prevent the
copper strands from splaying within the terminal.
All electrical installation work, in particular protective measures, must be
carried out in compliance with BS7671 regulations, statutory provisions and
‘best industry practice’ of the respective utilities provider.
The electrical installation may only be carried out in compliance with the
installation instructions by a suitably qualified electrician.
Electrical Connections
The wires within the supply cord are coloured in accordance with the
following code:
BLUE:
NEUTRAL
BROWN:
LIVE
GREEN/YELLOW
EARTH
WARNING THIS APPLIANCE MUST BE EARTHED