2 INTRODUCTION 

 

2.1 Overview

 

 

This manual contains instructions for the operation of the Eguana Evolve™ home energy storage system. This product, when 
installed, is permanently wired to the home electrical panel. 
 

There are two main components as shown below, including the energy storage system (1), and the energy meters installed in the 
main electrical panel (2).  Your system may include one or two meters, depending on the solar system that is installed. 

 

 

This product is intended to operate in parallel with a utility connected solar PV system, and is designed to manage the 

consumption of utility or solar energy within the home.  The system is capable of providing limited backup power to the home in 
case of a grid outage, as well as charge batteries from the solar system.  A sample diagram below shows a typical layout of an AC 
coupled solar plus storage system.  

 

 

 

 

Your system may be installed in a manner differently than shown above.  In addition, in accordance with your local electrical code, 
your installer may have included dedicated emergency disconnect switches for your battery and solar systems.  Consult your 
system installer regarding the application and installation setup of your specific system.  Refer to the Installer Checklist at the end 

of this document regarding information to be provided to you from your certified system installer. 
 

The backup electrical panel shown is a dedicated electrical bus separated from the main electrical bus.  While they are shown as 
two independent panels above, in many cases, the backup bus resides within the main panel. 

 

 

 

 

Solar 

Inverter 

Solar panels 

Evolve 

Battery 

System 

Main 

Electrical 

Panel 

Backup 

Electrical 

Panel 

Home 

Internet 
Service 

1

 

2

 

Air inlet 

Air exhaust 

Air exhaust 

Display 

Air inlet 

Panel mounted 
energy meter 

Содержание Evolve 0513

Страница 1: ...Eguana Evolve Model Evolve 0513 DO 68025 Evolve Owner s Manual ...

Страница 2: ...hock serious injury or death Operating the product in a way that it was not intended can also result in permanent damage to the product This manual applies to the following products Evolve 0513 Energy Storage System Warranty The Eguana Evolve includes a 10 year standard warranty with performance pro rating for the battery modules Please review the warranty statement included with your product IMPO...

Страница 3: ...GENCY 1 1 3 ENVIRONMENTAL PROTECTION 2 2 INTRODUCTION 3 2 1 OVERVIEW 3 2 2 SYSTEM MONITORING ACCOUNT SETUP 4 3 OPERATION 4 3 1 LED DISPLAY INDICATORS 4 3 2 SERVICE BUTTON 5 4 BACKUP POWER OPERATION 5 5 MAINTENANCE 5 6 TROUBLESHOOTING 6 7 INSTALLER CHECKLIST 6 ...

Страница 4: ... to the installed location In case of fire When safe use a fire extinguisher suitable for use including A B and C dry chemical fire extinguishers or carbon dioxide extinguishers Do not use type D extinguishers In case of flooding Stay out of water if any part of the system or wiring is submerged Do not attempt to operate batteries that have been submerged in water even after they have been dried I...

Страница 5: ...trical panel Ensure proper electrical grounding in accordance with code requirements CAUTION Both AC and DC voltage sources are terminated inside this equipment Each circuit must be disconnected before servicing Risks of Damage The PCS is compatible with the LG Chem battery model EM048126P3S7 only Do not attempt to connect any other battery to the system Do not connect any other loads directly to ...

Страница 6: ...ram below shows a typical layout of an AC coupled solar plus storage system Your system may be installed in a manner differently than shown above In addition in accordance with your local electrical code your installer may have included dedicated emergency disconnect switches for your battery and solar systems Consult your system installer regarding the application and installation setup of your s...

Страница 7: ...s present operating conditions 3 1 LED Display Indicators The display panel provides indication of the following Battery status state of charge System operating mode out of Service Indicator To conserve energy the LEDs will turn off after 5 minutes from being activated They can be re activated by pressing the service button Indicator Status Display type Color Battery Status State of charge L R 5 L...

Страница 8: ...er in the home will be interrupted for up to four seconds before backup power generation commences As a result of this interruption a desktop or portable UPS is recommended if continuous uninterrupted operation is desired for any sensitive electronic equipment In the event that there is not enough solar generation to maintain battery operation in an extended duration grid outage the battery system...

Страница 9: ... connection is via wi fi reboot wireless router and make sure login user and password have not been changed since time of original installation Check power to the Evolve energy management system via the orange indicator light on the right side of the panel Note the energy management system may lose power after an extended grid outage where there is not enough solar generation to maintain battery s...