Содержание Eggnest XR 2.0

Страница 1: ...1...

Страница 2: ...se x ray imaging to perform life saving diagnostic and therapeutic procedures for patients If you have suggestions for improvements please contact us at www eggmedical com info or write us at info egg...

Страница 3: ...3...

Страница 4: ...tform to the x ray table 13 Step 4 Attach the Side Flex Shields onto the around the EggNest XR Platform 14 Step 5 Insert the Arm Boards 15 Step 6 Insert the Clear Spot Shield 15 Step 7 Insert the Work...

Страница 5: ...ve use The effectiveness of the EggNest XR in blocking scatter radiation depends on proper use of the shielding system The set up of x ray procedure rooms varies Each EggNest XR should be configured f...

Страница 6: ...iber shell consists of two carbon fiber pieces an upper shell that has integrated supports for the arm boards and a lower shell I The two shells are joined together during the manufacturing process wi...

Страница 7: ...the patient loading patient left shown Each Arm Board attaches to Base Platform using a cylindrical connector that fits into the Receiving Channels on the Base Platform The body of the arm board is ra...

Страница 8: ...ulled away from the table using the handle that is on the longer arm This will cause the Arm Board to move outward as well The movement is intended to facilitate radial or brachial artery access by ab...

Страница 9: ...here are two Head Flex Shields one right and one left The Head Flex Shield has three components a A support bar that fits over and attaches to the Head Rail on the Base Platform b Low profile knobbed...

Страница 10: ...l of the Base Platform typically on the right side of the platform It has a U bracket under the Workbench that will attach to the Side Leg Rail The top surface is attached to the middle horizontal sur...

Страница 11: ...ield in the room not an EggNest component Also the Clear Spot Shield with Hanging Drape requires a sterile drape to cover both the shield and the flexible arm The Clear Spot Shield is a transparent ac...

Страница 12: ...left and right Corner Head Flip Shield are positioned around the top mattress and can be easily removed The Corner Head Flip Shield provides radiation protection built into the top and bottom of the...

Страница 13: ...R Base Platform to the x ray table Ensure that the strips are tightly connected in order to prevent the Base Platform from moving There are two loops in the arm board on each side The portion of the l...

Страница 14: ...the EggNest XR Platform b The existing Table Shield also referred to as the Table Skirt should be positioned slightly outside of the Side Flex Shields overlapping the two shields c Attach the Left and...

Страница 15: ...ert the Workbench onto the large Side Leg Rail To attach the Workbench by placing the U channel onto the Side Rail Once placed on the rail the Workbench can be adjusted left or right to border with th...

Страница 16: ...e attached the Head Shield After the shield is in place on the four screws tighten them to secure the Pillow Shield to the Head Shield rail Once in place the Pillow Shield can be raised and lowered as...

Страница 17: ...loading and unloading The Corner Head Shield has a top and bottom carbon fiber board that provides radiation protection from the X ray beam coming through the table The patient s sheet and pillow are...

Страница 18: ...flaps down 4 If loading from the left remove the Clear Spot shield and stow 5 If using a patient bed slide the bed next to the EggNest XR i Using a sliding board or hover mat move the patient from th...

Страница 19: ...on will be impaired 8 Once the patient is resting on the EggNest XR raise all the flip shields left and right Arm Board Workbench left and right Head Corner Shield and Pillow Shield Then position the...

Страница 20: ...uring the procedure under the sterile drape to accommodate access and optimize shielding Tips for optimal use of the EggNest XR Make sure that the patient head is aligned just below the top of the Egg...

Страница 21: ...es from the top of the EggNest XR and in the middle of the long axis of the system For more safety from roll off accidents we recommend using the accessory Security Belt attached to the EggNest XR con...

Страница 22: ...shield could be a lead to detachment with subsequent injury Similarly if the clear acrylic is cracked do not use the shield as it is possible that the crack will propagate and the shield will detach...

Страница 23: ...lds can be partially or completely removed to facilitate biplane imaging systems but the level of staff protection will be lower Can radial access procedures be performed using the EggNest XR Yes radi...

Страница 24: ...ad apron and also markedly reduce scatter radiation to uncovered parts of the body such as the calf foot arm neck and head Can or should I continue to use the table skirt and hanging shields The EggNe...

Страница 25: ...t about 2 4 inches higher with respect to the patient You should try the set up before proceeding to sterile draping Can a RadPad be used with the EggNest XR Yes the EggNest XR is compatible with othe...

Страница 26: ...to that used for most x ray tables The vinyl top is Reflex vinyl with Permablock3 sealant and with Silverguard antibacterial coating The EggNest XR should be cleaned between uses with one of the follo...

Страница 27: ...adhesive seal 3M Tegaderm Transparent Film Dressing to the area until the EggNest XR is repaired Periodic x ray examination As with lead aprons all flexible shielding should be periodically examined f...

Страница 28: ...ains structural failure due to misuse such as breaking the sled or arm boards from inappropriate movement of the x ray gantry or dropping the unit on the floor Repetitive flexing of any radiation bloc...

Страница 29: ...cern please go to the website www eggmedical com and click the Contact Us tab Alternatively you can call 612 916 6616 during business hours 8 00 AM to 5 00 PM Central Time Monday through Friday Egg Me...

Страница 30: ...Workbench Complete 0 5 mm 6 0 2 8 Clear Spot Shield Translucent portion 0 5 mm 5 5 2 6 The edges of the Base Platform shell and Foam Top are lined with shielding material except the area inside the ar...

Страница 31: ...User Manual EggNest XR 2 0 Page 31 of 31 MSDS Information for the EggNest XR...