27
D. AC Current
Range
Resolution
Accuracy
Overload Protection
400µA
0.1µA
±(1.5%+5)
500mA/250V fast type
fuse Ø5x20mm
4000µA
1µA
40mA
10µA
±(2%+5)
400mA
100µA
4A
1mA
±(2.5%+5)
Un-fused
10A
10mA
Remark:
- At 10A Range: For continuous measurement 10 seconds and interval not less than 15 minutes.
- Input impedance: approx. 10MΩ.
- Measurement voltage drop: Full range at 400mV.
E. Resistance
Range
Resolution
Accuracy
Overload Protection
400Ω
0.1Ω
±(1.2%+2)
250V DC or AC
4kΩ
1Ω
±(1%+2)
40kΩ
10Ω
400kΩ
100Ω
4MΩ
1kΩ
±(1.2%+2)
40MΩ
10kΩ
±(1.5%+2)
F. Diodes and Continuity Measurement
Range
Resolution
Remark
Overload Protection
1mV
Displays approximate forward
voltage drop reading
250V DC or AC
0.1Ω
Buzzer beeps at <100Ω
G. Transistor hFE Test
Range
Resolution
Overload Protection
hFE
Can test NPN and PNP type transistor.
Displays range: 0-1000
Ibo 10mA